![Landis+Gyr Gridstream RF Series IV Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/landis-gyr/gridstream-rf-series-iv/gridstream-rf-series-iv_installation-and-user-manual_673737026.webp)
Chapter 3 - RadioShop and Endpoint Testing Manager (ETM)
Gyr
26
98-1178 Rev AA
Installation and User Guide
4.
Once connected, the local radio's LAN address will appear on the list at the top left-hand side of
the screen, and a radio configuration report will be displayed in the main window.
Figure 3 - 2. Local Radio LAN Address
5.
If your Extender is new, you must make sure your Local Radio is on Network ID 670.
NOTE: In the example above, the Network Id of the Local Radio is 450. It must be changed to 670
to be able to communicate with a new Extender. If the Extender already has been assigned a
network ID, the radio must be changed to match.
Configure Local Radio to Match the Extender Network ID
To change the Network ID of the Local Radio, perform the following steps.
NOTE: All Gyr Gridstream radios, including the Extender, ship with a default network ID, or
CRC, of 670. In order to communicate with the new Extender, your local radio will have to be
reconfigured to match the network ID (670) of the Extender. After reconfiguring the Extender to
match the customer’s unique network ID, the local radio will need to be reset to its original network
ID.
1.
Select
Configure > Change Network Id (CRC)...
, the Network ID Wizard is displayed.
Figure 3 - 3. Specify New Network
2.
Click
Next
.
3.
Specify 670 or Extender’s ID for both the Network ID and Name of the new network, and click
Next
to continue.