Landis+Gyr CASHPOWER SABRE MK 5 Скачать руководство пользователя страница 15

Filename: User Guide Sabre Mk5 Rev 0.0.doc 

Page 15 of 28

 

5.5.1.5. Set Power Limit Voucher 

This voucher sets the power limit level for the meter – refer to paragraph 5.7. 

5.5.1.6. Set Credit Alarm Levels Voucher (Proprietary Voucher) 

On accepting a credit alarm level number, the meter sets the appropriate high and 
low 

credit levels

.  These are the levels at which the segments in the ‘wedge’ of the 

LCD 

credit indicator

 toggle – refer to paragraph 4.8 above.  

Note: 

If any of the credit levels transferred via the token is zero, the token is 

accepted, but the respective credit level is not updated. 

Note: The set credit levels token is not defined in the STS specification. It is a 
CASHPOWER specific feature, and it uses one of the proprietary dispenser specific 
management token subclasses.

 

5.5.1.7. Clear Credit Voucher 

On accepting a 

clear credit

 voucher, the meter clears any remaining credit to zero 

and opens the load switch, thus interrupting the electricity supply to the customer. 

5.5.1.8. Initiate Dispenser Test Voucher (Meter Non-Specific Voucher) 

There are a number of 

non meter-specific

 vouchers that can be used to test 

various functions on the meter. 

On accepting an 

initiate dispenser test

 voucher, the meter executes all the tests that are 

embedded in that particular voucher. The following tests are supported: 

Function 

Voucher Number 

Open the load switch 

0000 0000 0001 5099 7584 

HMI test - turns on all the 

LED’s

, displays all 

segments on the 

LCD

, and activates the 

buzzer

 

0000 0000 0001 6777 4880 

Display the 

total units counter

 

0000 0000 0002 0132 8896 

Display the 

key revision number

 and 

key type

 

1844 6744 0738 4377 2416 

Display the 

tariff index

 

3689 3488 1475 5332 2496 

Display the 

power limit

 level 

0000 0000 0012 0797 4400 

Display the 

tamper state

 

0000 0000 0022 8172 8512 

Display the 

instantaneous power

 

0000 0000 0044 2920 8064 

Display the 

software version

 number 

0000 0000 0087 2419 5840 

Test all 

the above functions (tests run 

sequentially) 

5649 3153 7254 5031 3471 

In a test sequence (

test all

), each test has a duration of 2.5 seconds, and is 

performed in the above order. For a single test per voucher, the test duration is 5 
seconds. 

On completion of the test sequence, the meter returns to its normal mode of 
operation. 

5.5.1.9. Commissioning Voucher (Non Meter-Specific, Proprietary Voucher) 

This is a 

non meter-specific

 voucher i.e. it can only be used on Gyr STS 

meter: 

1268 2136 5508 1001 3746 

It is typically used to assist meter installation personnel by ensuring that the load 
remains disconnected and the 

tamper

 detect sensing switch function disabled 

(meter 

decommissioned

).  Once the installation is complete and the number 

entered, the load switch closes and the 

tamper

 detect sensing switch function is 

enabled. 

Note:  An already commissioned meter rejects a commissioning token.

 

Note: The commissioning token is a supplier specific STS voucher.

 

Содержание CASHPOWER SABRE MK 5

Страница 1: ...Prepayment Electricity Metering System DOMESTIC Landis Gyr CASHPOWER SABRE MK 5 USER S GUIDE...

Страница 2: ...and update of product pictures Abstract This document is the User Guide for the Cashpower Sabre Mk5 Common Base keypad prepayment meters designed and developed by Landis Gyr Pty Ltd South Africa Refe...

Страница 3: ...Key Change Number 13 5 4 2 3 Voucher Not Accepted By Meter 13 5 4 2 4 Duplicate Voucher 13 5 4 2 5 Expired Voucher 13 5 4 2 6 Voucher Overflow Rejection 13 5 5 Voucher Decryption and Processing 14 5...

Страница 4: ...11 Meter State Register UPPER Register 030 24 6 12 Meter State Register LOWER Register 031 1 24 6 13 Fixed Option Register Register 033 25 6 14 Changeable Option Register Register 035 25 6 15 Volatil...

Страница 5: ...e commissioning of the meter to be done after the installation of the base thereby adding flexibility and installation convenience Included with the base is a Metal Oxide Varistor MOV which ensures th...

Страница 6: ...gure 2 Cashpower Sabre Front Panel Features Figure 3 Close up of the Cashpower Sabre membrane and LCD display features Anti tamper sealing clip Liquid Crystal Display LCD Anti tamper sealing clips Mem...

Страница 7: ...abre ED meter is set to 1000 impulses kWh The rate LED will therefore flash 1000 times for every kWh of energy consumed 3 4 Meter Label Set The meter label set shows the unique meter numbers type numb...

Страница 8: ...ear and unambiguous visual indication of the important meter functions by means of language independent pictograms The LCD has three functional blocks a numerical display for displaying various values...

Страница 9: ...red the sad face would come on Similar responses would apply during token entry e g entering an invalid CTN would result in the sad face flashing for a short period of time 4 4 Contactor Status Indica...

Страница 10: ...ns as follows All four credit wedge icons are displayed if the value in the current credit register is above the preset high credit level The three smallest wedge icons are displayed if the value in t...

Страница 11: ...meter by keying in the numbers printed on the credit voucher via the keypad The numbers entered are displayed on the LCD as they are being entered and scroll from right to left with a space displayed...

Страница 12: ...entered into the meter it will result in one of the display sequences described below 5 4 1 Incomplete Voucher A voucher entry is timed out if no key is pressed for more than 30 seconds On time out T...

Страница 13: ...is turned off The sad face icon is flashed for the reject time NB The reject function is included to discourage the entry of random numbers in an attempt to defraud the meter The reject time will even...

Страница 14: ...voucher meter specific proprietary voucher refer to paragraph 5 5 1 11 Set Options Register meter specific proprietary voucher Refer to paragraph 5 5 1 12 below 5 5 1 1 Electricity Credit Voucher The...

Страница 15: ...er Open the load switch 0000 0000 0001 5099 7584 HMI test turns on all the LED s displays all segments on the LCD and activates the buzzer 0000 0000 0001 6777 4880 Display the total units counter 0000...

Страница 16: ...detect this and enter into the tampered mode thereby disconnecting the supply to the customer A meter specific tamper reset voucher then needs to be generated at the vending system to rectify the sit...

Страница 17: ...ch time as a key is pressed on the keypad Using the example of a power limit trip refer to paragraph 5 7 the load switch will open and remain open for a period of 30 seconds At the end of this 30 seco...

Страница 18: ...authorised entry to the system is attempted Figure 7 Factory sealed screw plugs In addition to the factory sealed screw plugs on the rear panels there is a facility for two utility wire seals on the f...

Страница 19: ...mper and disconnect the load should SRE be detected The reverse energy condition may be monitored by using the information functions refer to paragraph 6 12 5 10 4 Magnetic Tamper Detection This new g...

Страница 20: ...nly be accessed when the meter is disconnected from power It allows for meter data such as remaining credit to be extracted in the event of an electronics failure NB From a safety point of view the me...

Страница 21: ...not have to be pressed again Information mode may be exited by pressing the information key or in the absence of any other key presses automatically after 1 minute Information Register Functions Info...

Страница 22: ...ate Time Format 350 50th Last Token s 20 Digit Transfer Number and ID in Date Time Format 600 Enter Customer Information Mode Refer to section 6 28 6 1 Meter Number Register 000 The meter displays the...

Страница 23: ...n is reset to zero The display is days on left hand side and consumption on right hand side 6 7 Previous 30 Day Consumption Register 009 The meter displays the previous 30 day period consumption 6 8 L...

Страница 24: ...meter state register This register indicates the current state of the following meter functions Meter State Register Lower Display Function 1xxx xxxx Latch Inhibit X1xx xxxx Significant reverse power...

Страница 25: ...used xxxx x1xx Enable creep lock xxxx xx1x Display negative credit xxxx xxx1 Reserved must be set to 1 6 14 Changeable Option Register Register 035 The meter displays the least significant eight bits...

Страница 26: ...n Engineering Mode Enable xxxx x1xx Not used xxxx xx1x Reason for latch hold back Overload Magnetic trip xxxx xxx1 Phase direction indicator 6 16 Volatile Meter State Lower Register 037 The meter disp...

Страница 27: ...S specification 6 24 Current Credit Register 10Wh Resolution Register 059 The meter displays the value of the credit register with a resolution of 0 01kWh The most significant digit of the display if...

Страница 28: ...e below Code Function 000 test all 001 open the disconnect device 002 switch all LCD segments on and flash the rate LED 004 display total units counter 005 display key revision and key type 006 displa...

Отзывы: