5.5.1.5. Set Power Limit Voucher
This voucher sets the power limit level for the meter – refer to paragraph 5.7.
5.5.1.6. Set Credit Alarm Levels Voucher (Proprietary Voucher)
On accepting a credit alarm level number, the meter sets the appropriate high and
low
credit levels
. These are the levels at which the segments in the ‘wedge’ of the
LCD
credit indicator
toggle – refer to paragraph 4.8 above.
Note:
If any of the credit levels transferred via the token is zero, the token is
accepted, but the respective credit level is not updated.
Note: The set credit levels token is not defined in the STS specification. It is a
CASHPOWER specific feature, and it uses one of the proprietary dispenser specific
management token subclasses.
5.5.1.7. Clear Credit Voucher
On accepting a
clear credit
voucher, the meter clears any remaining credit to zero
and opens the load switch, thus interrupting the electricity supply to the customer.
5.5.1.8. Initiate Dispenser Test Voucher (Meter Non-Specific Voucher)
There are a number of
non meter-specific
vouchers that can be used to test
various functions on the meter.
On accepting an
initiate dispenser test
voucher, the meter executes all the tests that are
embedded in that particular voucher. The following tests are supported:
Function
Voucher Number
Open the load switch
0000 0000 0001 5099 7584
HMI test - turns on all the
LED’s
, displays all
segments on the
LCD
, and activates the
buzzer
0000 0000 0001 6777 4880
Display the
total units counter
0000 0000 0002 0132 8896
Display the
key revision number
and
key type
1844 6744 0738 4377 2416
Display the
tariff index
3689 3488 1475 5332 2496
Display the
power limit
level
0000 0000 0012 0797 4400
Display the
tamper state
0000 0000 0022 8172 8512
Display the
instantaneous power
0000 0000 0044 2920 8064
Display the
software version
number
0000 0000 0087 2419 5840
Test all
the above functions (tests run
sequentially)
5649 3153 7254 5031 3471
In a test sequence (
test all
), each test has a duration of 2.5 seconds, and is
performed in the above order. For a single test per voucher, the test duration is 5
seconds.
On completion of the test sequence, the meter returns to its normal mode of
operation.
5.5.1.9. Commissioning Voucher (Non Meter-Specific, Proprietary Voucher)
This is a
non meter-specific
voucher i.e. it can only be used on Gyr STS
meter:
1268 2136 5508 1001 3746
It is typically used to assist meter installation personnel by ensuring that the load
remains disconnected and the
tamper
detect sensing switch function disabled
(meter
decommissioned
). Once the installation is complete and the number
entered, the load switch closes and the
tamper
detect sensing switch function is
enabled.
Note: An already commissioned meter rejects a commissioning token.
Note: The commissioning token is a supplier specific STS voucher.