Fuel Grade/Type
Comments
JP 8 Turbine Fuel
5-12% reduction in
power and up to 30%
reduction in fuel system
component and cylinder
life.
JP 5 Turbine Fuel
Refer to JP 8
DF A Arctic
Acceptable fuel for use
in sub-zero ambients
only.
Component failure that can be directly attributed to the
use of fuels other than those recommended cannot be
covered under warranty.
Fuel Pressure Adjustment:
To control water temperature, adjust fuel pressure
by turning the regulating pressure adjusting screw
clockwise to increase, counterclockwise to decrease.
Do not exceed 200 psi.
NOTE: When changing fuel
pump, a bypass plug must be installed in return port
or fuel pump will not prime.
Burner Nozzle:
Keep the tip free of surface deposits by wiping it with
a clean, solvent saturated cloth, being careful not to
plug or enlarge the nozzle. For maximum efficiency,
replace the nozzle each season.
Electrodes Setting:
(See Illustration Below)
Air Adjustment:
The oil burner on this machine is preset for
operation at altitudes below 1000 feet. If operated at
higher altitudes, it may be necessary to adjust the air
band setting. Adjust air band for #1 or #2 smoke spot
on the Bacharach scale. A one-time initial correction
for your location will pay off in economy, performance,
and extended service life. If a smoky or eye-burning
exhaust is being emitted from the stack, two things
should be checked. First, check the fuel to be certain
that kerosene or No. 1 home heating fuel is being used.
Next, check the air adjustment on the burner.
LANDA Sure Fire Oil Burner
Burner Air Adjustment: The oil burner on this machine
is preset for operation at altitudes below 1000 feet. If
operated at higher altitudes, it may be necessary to
adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.
Burner Air Adjustment
CAUTION:
If white smoke appears from burner
exhaust vent during start-up or operation, discon-
tinue use and readjust air bands.
NOTE: If a flue is installed, have a professional
serviceman adjust your burner for a #1 or #2 smoke
spot on the Bacharach scale.
Coil Removal:
Removal of coil because of freeze breakage, or to clean
soot from it can be done quickly and easily.
1. Disconnect hose from pump to inlet side of the coil.
2. Carefully disconnect the thermostat sensor making
sure you do not crimp the capillary tube.
3. Remove burner assembly from combustion
chamber.
4. Remove the 3-3/8" bolts from each side of coil and
tank assembly (these bolts are used to fasten tank
to chassis).
5. Remove fittings connected to the 1/2" pipe nipples
from inlet and discharge sides of coil.
1/16"
5/32" Gap
Nozzle
7/16"
Top View
Side View
89199800-23
Electrode
Reference Numbers
Air Band Locking Screws
Air Band