![Landa SDHW Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/landa/sdhw-series/sdhw-series_operators-manual_3819551014.webp)
14
Maintenance
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
LOW OPERATING
PRESSURE
Faulty pressure gauge
Install new gauge.
Insufficient water supply
Use larger supply hose; clean filter at water inlet
and at bottom of float tank.
Old, worn or incorrect spray nozzle
Match nozzle number to machine and/or replace
with new nozzle.
Belt slippage
Tighten or replace; use correct belt.
Plumbing
or hose leak
Check plumbing system for leaks.
Retape leaks with teflon tape.
Faulty or misadjusted unloader valve
Adjust unloader for proper pressure.
Worn packing in pump
Call local Landa Dealer.
Fouled or dirty inlet or discharge valves in
pump
Clean inlet and discharge valves.
Worn inlet or discharge valves
Call local Landa Dealer.
Obstruction in spray nozzle
Remove obstruction.
Leaking pressure steam valve
Replace as needed.
Slow engine RPM
Set engine speed at proper specifications. See
serial plate.
BURNER WILL
NOT LIGHT
Little or no fuel
Fill tank with fuel.
Improper fuel or water in fuel
Drain fuel tank and fill with proper fuel.
Clogged fuel line
Clean or replace.
Plugged fuel filter
Replace as needed.
Misadjusted burner air bands
Readjust air bands for clean burn.
Little or no fuel pressure from fuel pump Increase fuel pressure to specification
and/or replace fuel pump.
Faulty burner
transformer
Test transformer for proper arc between
contacts. Replace as needed.
Disconnected or short
in electrical wiring
All wire contacts should be clean and tight. No
breaks in wire.
Flex coupling slipping on fuel pump shaft
or burner motor shaft
Replace if needed.
On-Off burner switch defective
Check for electrical current reaching burner
assembly with burner switch on.
Heavy sooting on coil and burner can
cause interruption of air flow and
shorting of electrodes
Clean as required.
Improper electrode setting
Check and reset electrodes.
Fuel not reaching
combustion chamber
Check fuel pump for proper flow. Check fuel
solenoid and flow switch. Call Landa Dealer.
Clogged burner nozzle
Replace.
Thermostat faulty or slow engine speed
Increase engine RPM to increase voltage.
Flow switch malfunction
Remove, test for continuity and replace as
needed.
Fuel solenoid malfunction
Replace if needed.
(For parts and information, call your Landa Dealer)
Landa SDHW6-35824 E/M Operator’s Manual 8.913-958.0 - AC
Содержание SDHW Series
Страница 2: ...2 Landa SDHW6 35824 E M Operator s Manual 8 913 958 0 AC Machine Data Label...
Страница 20: ...20 Notes Landa SDHW6 35824 E M Operator s Manual 8 913 958 0 AC...
Страница 36: ...36 Wayne Burner EHASR AC Series Landa SDHW6 35824 E M Operator s Manual 8 913 958 0 AC...
Страница 40: ...8 913 958 0 Printed in U S A...