13
Operations
Shutting Down And
Clean-up
STEP 1:
Remove detergent suction
tube from container and insert into
one (1) gallon of fresh water. Pull
trigger on spray gun and siphon
water for one minute.
STEP 4:
Squeeze trigger on spray
gun to relieve remaining pressure.
STEP 2:
Turn burner switch off and
continue spraying, allowing the
water to cool to below 100°F.
STEP 5:
Remove water supply
hose.
STEP 3:
Turn engine key switch off
and turn off water.
STEP 6:
Disconnect high pressure
hose from high pressure outlet.
Landa PGDC Operator’s Manual 8.916-596.0 - P