INTRODUCTION

Thank you for purchasing a Landa Pressure Washer.

This manual covers the operation and maintenance of
the PE3-11021D, PE4-20021A, PE4-20021B,
PE4-20021C, PE4-30021A, PE4-30021B, PE4-30021C,
PE5-30021A,  PE5-30021B, PE5-30021C and
PE5-30021F washers.  All information in this manual is
based on the latest product information available at the
time of printing.

Landa, Inc. reserves the right to make changes at any
time without incurring any obligation.

The PE Series was designed for maximum

use of 8 hours per day, 5 days per week.

Owner/User Responsibility:

The owner and/or user must have an understanding of
the manufacturer’s operating instructions and warnings
before using this Landa pressure washer. Warning infor-
mation should be emphasized and understood. If the op-
erator is not fluent in English, the manufacturer’s instruc-
tions and warnings shall be read to and discussed with
the operator in the operator’s native language by the pur-
chaser/owner, making sure that the operator compre-
hends its contents.

Owner and/or user must study and maintain for future
reference the manufacturers’ instructions.

This manual should be considered a permanent
part of the machine and should remain with it if
machine is resold.

When ordering parts, please specify model and
serial number.

IMPORTANT SAFETY
INSTRUCTIONS

WARNING: When using this machine basic precau-
tions should always be followed, including the
following:

CAUTION: To reduce the risk of
injury, read operating instruc-
tions carefully before using.

1. Read the owner's manual thor-

oughly. Failure to follow instruc-
tions could cause malfunction
of the machine and result in
death, serious bodily injury and/
or property damage.

2. Know how to stop the machine and bleed pressures

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.

4. All installations must comply with local codes. Con-

tact your electrician, plumber, utility company or the
selling distributor for specific details.

To comply with the National Electrical Code (NFPA
70) and provide additional protection from risk of elec-
tric shock, these pressure washer are equipped with
a UL approved ground fault circuit interrupter (GFCI)
power cord (PE3-11021D and PE4-20021A models
only). All other models must be connected to a GFCI
circuit breaker.

WARNING: Flammable liquids
can create fumes which can ig-
nite causing property damage or
severe injury.

WARNING:  Risk of explosion —
do not spray flammable liquids.

5. Risk of explosion - do not spray

flammable liquids or operate in
an explosive location.

WARNING: Keep water spray
away from electric wiring or fatal
electric shock may result.

6. To protect the operator from

electrical shock, the machine
must be electrically grounded.
It is the responsibility of the
owner to connect this machine
to a UL grounded receptacle of

proper voltage and amperage ratings.  Do not spray
water on or near electrical components.  Do not touch
machine with wet hands or while standing in water.
Always disconnect power before servicing.

7. Grip cleaning wand securely with both hands before

star ting the cleaner. Failure to do this could result in
injury from a whipping wand.

WARNING: High pressure stream
of fluid that this equipment can
produce can pierce skin and its
underlying tissues, leading to se-
rious injury and possible ampu-
tation.

8. High pressure developed by

these machines will cause per-
sonal injury or equipment dam-
age. Use caution when operat-

ing. Do not direct discharge stream at people, or se-
vere injury or death will result.

9. Never make adjustments on machine while in

operation.

WARNING

READ OPERATOR’S

MANUAL

THOROUGHLY

PRIOR TO USE.

WARNING

RISK OF EXPLOSION:

DO NOT USE WITH

FLAMMABLE LIQUIDS.

WARNING

KEEP  WATER SPRAY

AWAY FROM

ELECTRICAL WIRING.

WARNING

RISK OF INJECTION
OR SEVERE INJURY
TO PERSONS. KEEP

CLEAR OF NOZZLE.

CAUTION

Содержание PE3-1100

Страница 1: ...UAL LANDA INC 4275 N W Pacific Rim Blvd Camas WA 98607 USA For technical assistance or the Landa Dealer nearest you call 800 LANDA 4 U 800 526 3248 or 360 833 9100 or consult our web page at www landa...

Страница 2: ...p in a safe place for future reference Introduction 3 Important Safety Instructions 3 4 Component Identification 4 Pre Operation Check 5 Set Up Procedures 5 Operating Instructions 5 General Washing Te...

Страница 3: ...ntrols 3 Stay alert watch what you are doing 4 All installations must comply with local codes Con tact your electrician plumber utility company or the selling distributor for specific details To compl...

Страница 4: ...t be cold and clean fresh water 16 To reduce the risk of injury close supervision is nec essary when a machine is used near children Do not allow children to operate the pressure washer This machine m...

Страница 5: ...INSTRUCTIONS 1 With power switch in OFF position plug power cord into a grounded type of receptacle of proper voltage and amperage reading Then push GFCI reset but ton at end of power cord if require...

Страница 6: ...ay gun to re lease pressure before removing discharge hose STORAGE Pump Storage CAUTION Always store your pressure washer in a location where the tem perature will not fall below 32 F 0 C The pump in...

Страница 7: ...nto the quick coupler of the wand 7 Open spray gun Water detergent ratio is approxi mately 15 to 1 8 When you finish washing rinse by simply releasing the spray gun removing the soap nozzle and re pla...

Страница 8: ...4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW LEFT SIDE 7 4 5 47 60 59 61 46 58 53 57 29 27 24 28 36 68 66 64 63 65 67 3 1 2 69 48 37 48 5 6 5 5 5 6 5 76 9 9 5 8 43 44 45 7 5 48 48 5 18 2...

Страница 9: ...EWASHER OPERATOR S MANUAL 9 LANDA PE REV 10 02 PE3 11021D PE4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW RIGHT SIDE 41 40 72 34 33 22 26 29 55 56 20 30 32 31 5 6 5 6 10 15 16 14 6 5 12b...

Страница 10: ...PE 1 95 07101022 Bracket Electric Box 4 3000A 5 3000A 1 24 10 08018 Label Warning Service Cord 1 25 2 0106 Cushion Pump 2 26 5 3022 Unloader General YVB75L EZ 3 1100 1 5 3025 Unloader General YVB75K47...

Страница 11: ...PH 1725 230V 1 PH 4 2000A 1 5 1011 Motor 6 HP 3 PH 1725 230V 460V 3 PH 4 2000B C 1 ITEM PART NO DESCRIPTION QTY 42 5 1018 Motor 10 HP 3 PH 1725 230V 460V 3 PH 5 30021B C 1 5 1013 Motor 7 5 HP 1 PH 17...

Страница 12: ...e Fiberglass Nema 4X except 3 1100 1 6 03909 Box Plastic 10 x 8 x 6 4 3000A 5 3000A 1 PE3 11021D PE4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW PARTS LIST CONTINUED ITEM PART NO DESCRIPT...

Страница 13: ...ON QTY 4 4 011231 Cover Wand All Models 1 5 Nozzles See Page 10 6 4 16540 Brass Soap Nozzle 1 7 4 011183 Detergent Injector 3 1100 1 4 011184 Detergent Injector All Models 1 8 2 2000 Coupler 1 4 Femal...

Страница 14: ...loader valve seat worn Check and replace if necessary Worn piston package Check and replace if necessary PUMP NOISY Air in suction line Check water supply and connections on suction line Broken or wea...

Страница 15: ...ld be approximately equal to isolate and correct the problem Over voltage or under voltage Check input voltage at each phase to motor Open stator winding Check stator resistance at all three phases fo...

Страница 16: ...n WARNING Do not touch electrical connections before you first ensure that power has been disconnected Electrical shock can cause serious or fatal injury Only qualified personnel should attempt the in...

Страница 17: ...rvice including adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While...

Страница 18: ...de alta presi n lejos del cableado electrico ya que puede ocurrir un choque fatal Lea la etiqueta de advertencia del cable electrico 3 Para proteger al operador de un choque el ctrico la m quina deber...

Страница 19: ...a de Alta Presi n Manguera Para Detergentes Manguera de Suministro de Agua no se incluye Medidor de Aceite Mirilla de Nivel de Aceite Conector no incluido on unidades de 230v 1fase Switch de Encendido...

Страница 20: ...r a 6 gpm 5 8 20 psi Manguera varilla boquilla tama o de boquilla seg n placa de serie Filtro de agua intacto no restrictivo Apropiada fuante el ctrica recept culo y caja de circuitos PROCEDIMIENTOS D...

Страница 21: ...avar Riegue a cierto ngulo a modo que golp e debajo de la mugre o materia y la deprenda 2 Cuando este lavando objetos grandes use un inyector detergente pcional para aplicar el detergente Empiece el l...

Страница 22: ...n del flujo 2 Conecte la manguera de descarga a presi n a la boquilla de inyector asegurando el conector r pido 3 Arranque la m quina como se indica en las instrucciones de operaci n 4 Coloque el tub...

Страница 23: ...a 4 Da o a los componentes debido a fluctuaciones en el suministro el ctrico o al abastecimiento de agua 5 Servicio de mantenimiento normal incluso los ajustes limpieza del sistema de combustible y de...

Страница 24: ...4275 NW Pacific Rim Blvd Camas WA 98607 USA Form 96 604 Revised 10 02 Printed in U S A by Landa Inc Camas WA 98607 WATER CLEANING SYSTEMS...