Maintenance

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

LOW OPERATING
PRESSURE

Faulty pressure gauge

Install new gauge.

Insufficient water supply

Use larger supply hose; clean filter at water inlet.

Old, worn or incorrect spray 
nozzle

Match nozzle number to machine and/or replace with 
new nozzle.

Belt slippage

Tighten or replace; use correct belt.

Plumbing or hose leak

Check plumbing system for leaks. Re-tape leaks with 
teflon tape.

Faulty or mis-adjusted unloader 
valve

Adjust unloader for proper pressure. Install repair kit 
when needed.

Worn packing in pump

Install new packing kit.

Fouled or dirty inlet or discharge 
valves in pump

Clean inlet and discharge valves.

Worn inlet or discharge valves

Replace with valve kit.

Obstruction in spray nozzle

Remove obstruction.

Leaking pressure control valve

Rebuild or replace as needed.

Slow engine RPM

Set engine speed at proper specifications.

Pump sucking air

Check water supply and possibility of air seepage.

Valves sticking

Check and clean or replace if necessary.

Unloader valve seat faulty

Check and replace if necessary.

BURNER WILL
NOT LIGHT

Little or no fuel

Fill tank with fuel.

Improper fuel or water in fuel

Drain fuel tank and fill with proper fuel.

Clogged fuel line

Clean or replace.

Plugged fuel filter

Replace as needed.

Mis-adjusted burner air bands

Readjust air bands for clean burn.

Little or no fuel pressure from 
fuel pump

Increase fuel pressure to specification and/or replace 
fuel pump. Test with pressure gauge.

Faulty burner transformer

Test transformer for proper arc between contacts. 
Replace as needed.

Disconnected or short in elec-
trical wiring

All wire contacts should be clean and tight. 
No breaks in wire.

Flex coupling slipping on fuel 

pump shaft or burner motor shaft

Replace if needed.

On-Off switch defective

Check for electrical current reaching 
burner assembly with burner switch on.

(continued on next 
page)

Heavy sooting on coil and burner 
can cause interruption of air flow 
and shorting of electrodes

Clean as required.

Landa PDHW Series Operator’s Manual  8.919-980.0 - B

Содержание PDHW5-35624E

Страница 1: ...n te el ctric a antes de dar servici o RISQU E D ELEC TROCU TION Tous les ls doiven t tre mainte nus secs et tre suspen dus No jamais projete r de l eau sur les com posant es et ls lectriq ues Couper...

Страница 2: ...means the engine is overheating Turn machine off and perform maintenance Glow Plug When the light is on the engine is being pre heated When the light turns off the engine can be started Low Oil When t...

Страница 3: ...Down Clean Up 13 Storage 14 Maintenance Service Unloader Valves 14 Winterizing Procedure 15 High Limit Hot Water Thermostat 15 Pumps 15 Cleaning of Coils 15 Rupture Disk 15 Fuel 15 Fuel Control System...

Страница 4: ...unsafe practices of the machine Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize the op...

Страница 5: ...e operator s native lan guage by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufacturers instruction...

Страница 6: ...starting make sure that the engine is as hori zontal as possible and observe the following steps in running this pressure washer a become familiar with how to stop the engine b never start the engine...

Страница 7: ...not present Do not store or use gasoline near this machine 10 Use Ultra Low Sulfur Diesel fuel only NEVER use gasoline in your diesel tank Gasoline is more combustible than diesel and could result in...

Страница 8: ...pen the spray gun to relieve pressure Failure to properly cool down or maintain the heating coil may result in a steam explosion 26 Do not overreach or stand on unstable support Keep good footing and...

Страница 9: ...et tre suspe ndus No jamai s projet er de l eau sur les com posan tes et ls lectr iques Coupe r l alim entata tion lectr ique avant de faire une r para tion RISK OF ELEC TROC UTION Keep all conne c t...

Страница 10: ...ll proper battery making sure that the red cable is attached to the positive terminal Use a 12V Group 24 battery Battery Installation Due to Federal Regulations concerning shipment of corrosive chemic...

Страница 11: ...is eraux endro its o une amm e nue est perm ise Ne pas vapor iser de liquid es in am mabl es RISQ UE DE FEU Ne pas ajou ter d s senc e de fuel tand is que la mach ine est en oper ation RISK OF EXPL OS...

Страница 12: ...a detergent injector Turn control panel detergent valve clockwise until closed if using the float tank option IMPORTANT You must flush the detergent injection system after each use by placing the suc...

Страница 13: ...esired high pressure nozzle NOTE You can also stop detergent from flowing by simply removing detergent siphon tube from bottle Shutting Down Clean Up STEP 1 Remove detergent suction tube from containe...

Страница 14: ...neutralize and flush detergent from system after use 4 If water is known to be high in mineral content use a water softener on your water system or de scale as needed 5 Do not allow acidic caustic or...

Страница 15: ...r for instructions Removal of Soot and Heating Coil In the heating process fuel residue in the form of soot deposits may develop between the heating coil pipe and block air flow which will affect burn...

Страница 16: ...itudes it may be necessary to adjust the air band for a 1 or 2 smoke spot on the Bacharach scale To adjust start machine and turn burner ON Loosen two locking screws found on the air band and close ai...

Страница 17: ...ure you do not crimp the capillary tube 4 Remove burner assembly from combustion chamber 5 Remove the 3 3 8 bolts from each side of coil and tank assembly these bolts are used to fasten tank to chassi...

Страница 18: ...pply and possibility of air seepage Valves sticking Check and clean or replace if necessary Unloader valve seat faulty Check and replace if necessary BURNER WILL NOT LIGHT Little or no fuel Fill tank...

Страница 19: ...may be necessary to contact your local authorized engine sales and service center for details MACHINE SMOKES WHILE BURNER UNIT IS RUNNING OR UNIT SMOKES AT COLD START ONLY WHEN BURNER IS OFF Improper...

Страница 20: ...ch Replace Incorrect fuel nozzle size Contact your local Landa Dealer Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOISY...

Страница 21: ...line s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves sticking...

Страница 22: ...Engine overload X X X X X X X Excessive parasitic load X X X Valve lash insufficient excessive X X X X Injection timing out of spec advanced X X X X X Injection timing out of spec retarded X X X Gove...

Страница 23: ...ally Replace High Pressure Nozzle Every 6 months Replace Quick Connects Annually Clean Water Screen Filter Weekly Replace HP Hose Annually Kubota Engine Maintenance Schedule Engine Oil SAE 10W 30 API...

Страница 24: ...8 919 980 0 Printed in U S A...

Отзывы: