manualshive.com logo in svg
background image

20

Maintenance

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

PUMP RUNNING 
NORMALLY BUT 
PRESSURE LOW ON 
INSTALLATION

Pump sucking air 

Check water supply and possibility of air 
seepage.

Valves sticking 

Check and clean or replace if necessary.

Unloader valve seat faulty

Check and replace if necessary.

Nozzle incorrectly sized

Check and replace if necessary (See serial 
plate for proper size).

Worn piston packing 

Check and replace if necessary.

FLUCTUATING 
PRESSURE

Valves worn

Check and replace if necessary.

Blockage in valve

Check and replace if necessary.

Pump sucking air

Check water supply and air see page at joints 
in suction line.

Worn piston packing

Check and replace if necessary.

PUMP NOISY

Air in suction line

Check water supply and connections on 
suction line.

Broken or weak inlet or discharge valve 
springs

Check and clean if necessary.

Excessive matter in valves

Check and clean if necessary.

Worn bearings

Check and clean if necessary.

PRESENCES OF WATER 
IN OIL

Oil seal worn

Check and replace if necessary.

High humidity in air

Check and change oil twice as often.

WATER DRIPPING FROM 
UNDER PUMP

Piston packing worn

Check and replace if necessary.

O-Ring plunger retainer worn

Check and replace if necessary.

Pump protector

Reduce inlet water pressure. Do not close 
trigger on spray gun for longer than 1-2 
minutes.

OIL DRIPPINGS

Oil seal worn

Check and replace if necessary.

MACHINE SMOKES

Improper fuel or water in fuel

Drain tank and replace contaminated fuel.

Improper air adjustment

Readjust air bands on burner assembly.

Low fuel pressure 

Adjust fuel pump pressure to specifications.

Weak fuel pump

Check fuel pump pressure. Replace pump if 
needed.

Fuel filter partially cogged 

Replace as needed.

Soot build up on coils

Clean coils with soot remover.

Lime build up in coils

Clean inside of coils using Landa's coil cleaner.

Improper burner nozzle

See combustion assembly breakdown

Landa HOT Series Operator’s Manual  8.917-208.0 - B

Содержание HOT Series

Страница 1: ...Washer ELY RIA OHI O U S A MODELS HOT 2 11024D 1 109 095 0 HOT 2 15024D 1 109 096 0 HOT 2 11026D 1 109 093 0 HOT 2 15026D 1 109 094 0 HOT 3 11024D 1 109 097 0 HOT 3 30036D 1 109 100 0 HOT 4 20024A 1...

Страница 2: ...2 Landa HOT Series Operator s Manual 8 917 208 0 B Machine Data Label...

Страница 3: ...3 Thermal Pump Protection 13 Cleaning Tips 13 Rinsing 13 Shutting Down Clean up 14 Storage 14 Engine Maintenance 14 Maintenance Preventative Maintenance 15 Unloader Valves 15 Winterizing Procedure 15...

Страница 4: ...s When placing an order for parts the machine model and machine serial number are important Refer to the MACHINE DATA box which is filled out during the installation of your machine The MACHINE DATA b...

Страница 5: ...r with the controls 3 Stay alert watch what you are doing 4 All installations must comply with local codes Contact your electrician plumber utility company or the selling dealer for specific details I...

Страница 6: ...c or abrasive fluids to pass through the pump 9 Never run pump dry or leave spray gun closed longer than 1 2 minutes 10 Keep operating area clear of all persons and animals WARNING High pressure spray...

Страница 7: ...fied in this manual 16 Inlet water must be clean fresh water and no hotter then 90 F WARNING Risk of asphyxiation Use this product only in a well ventilated area AVERTISSEMENT Risque d asphyxie Utilis...

Страница 8: ...Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 Pump S...

Страница 9: ...and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans AVERTISSEMENT viter les petites superficies ou les surfaces proximit des ventilateurs d extr...

Страница 10: ...ar back If detergent is to be applied insert a detergent injector Insert quick coupler onto discharge nipple and secure by pushing quick coupler collar forward STEP 5 Release the coupler collar and pu...

Страница 11: ...g water to flush through the system until clear Turn pump switch ON or turn knob to pump position When a steady stream of water flows from the spray gun and wand the machine is ready for the high pres...

Страница 12: ...e must be inserted at end of wand to obtain high pressure Variable Pressure Wand Assembly Models using variable pressure wands grip spray gun securely Turn variable pressure control handle counter clo...

Страница 13: ...tion and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surfa...

Страница 14: ...s CAUTION Failure to follow the above directions will result in damage to your pressure washer ATTENTION Le non respect des directives ci dessus entra nera des dommages la laveuse pression When the pr...

Страница 15: ...tested at the factory before shipping Tampering with the factory setting may cause personal injury and or property damage and will void the manufacturer s warranty Winterizing Procedure Damage due to...

Страница 16: ...ustration Ignition Circuit Periodically inspect wires spring contact and elec trodes for condition security and proper spacing Transformer test CAUTION 10 000 VOLTS use defect free insulated screwdriv...

Страница 17: ...urn air shutter halfway back to the black smoke position previously noted Tighten locking screws If the desired position cannot be obtained using only the air shutter lock the air shutter in as close...

Страница 18: ...enance Schedule Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean Burner Filter Annually Remove Burner Soot From He...

Страница 19: ...on coils not allowing heat transfer Clean coils Lime deposits on inside of coil Delime coil WATER TEMPERATURE TOO HOT Defective high limit switch Replace Insufficient water supplied Check water G P M...

Страница 20: ...lves Check and clean if necessary Worn bearings Check and clean if necessary PRESENCES OF WATER IN OIL Oil seal worn Check and replace if necessary High humidity in air Check and change oil twice as o...

Страница 21: ...an as required Improper electrode setting Clean and test according to diagram in Operators Manual Fuel not reaching combustion chamber Check fuel pump for proper flow Check solenoid flow switch on mac...

Страница 22: ...8 917 208 0 Printed in U S A...