manualshive.com logo in svg
background image

14

Operations

Shutting Down & 
Clean-up

STEP 1:

 Remove 

detergent suction tube 
from container and insert 
into one (1) gallon of 
fresh water. Pull trigger 
on spray gun and siphon 
water for one minute.

STEP 2:

 Turn pump 

switch ON or turn knob to 
pump position then open 
spray gun to allow water 
to cool.

STEP 3:

 After water has 

cooled to less than 100°, 
turn switch or knob to 
OFF and turn off water.

STEP 4:

 Squeeze trigger 

on spray gun to relieve 
remaining pressure. 
Move shut-off gun safety 
latch into its locked 
position.

Landa HOT Series Operator’s Manual  8.917-208.0 - B

Storage

CAUTION: Always store your pressure washer in a
location where the temperature will not fall below 32°F
(0°C). The pump in this machine is susceptible to per-
manent damage if frozen. FREEZE DAMAGE IS NOT
COVERED BY WARRANTY.
ATTENTION: Toujours entreposer la laveuse à 
pression dans un endroit où la température ne sera 
pas inférieure à 32°C (0 °F). La pompe sur cette 
machine est susceptible de subir des dommages si 
elle est exposée au gel. LES DOMMAGES DUS AU GEL 
NE SONT PAS COUVERTS PAR LA GARANTIE.

1. Stop the pressure washer, squeeze spray gun 

trigger to release pressure.

2. Detach water supply hose and high pressure hose.

3. Turn on the machine for a few seconds, until 

remaining water exits. Turn engine off immediately.

4. Drain the gas and oil from the engine.

5. Do not allow high pressure hose to become kinked.

6. Store the machine and accessories in a room which 

does not reach freezing temperatures.

CAUTION: Failure to follow the above directions will 
result in damage to your pressure washer.
ATTENTION: Le non-respect des directives ci-dessus 
entraînera des dommages à la laveuse à pression

When the pressure washer is not being operated or is 
being stored for more than one month, follow these instruc-
tions:

1. Replenish engine oil to upper level.

2. Drain gasoline from fuel tank, fuel line, fuel valve and 

carburetor.

3. Pour about one teaspoon of engine oil through the 

spark plug hole, pull the starter grip several times and 
replace the plug. Then pull the starter grip slowly until 
you feel increased pressure which indicates the piston 
is on its compression stroke and leave it in that 
position. This closes both the intake and exhaust 
valves to prevent rusting of cylinder.

4. Cover the pressure washer and store in a clean, dry 

place that is well ventilated away from open flame or 
sparks. 

NOTE: The use of a fuel additive, such as STABIL

®

, or 

an equivalent, will minimize the formulation of fuel 
deposits during shortage. Such additives may be added 
to the gasoline in the fuel tank of the engine, or to the 
gasoline in a storage container.

A

fter Extended Storage

CAUTION: Prior to restarting, thaw out any 
possible ice from pressure washer hoses, 
spray gun or wand.

ATTENTION: Avant de redémarrer, faire fondre la glace 
se trouvant sur les boyaux, le pistolet pulvérisateur ou 
la lance de la laveuse à pression

Engine Maintenance

During the winter months, rare atmospheric conditions 
may develop which will cause an icing condition in the 
carburetor. If this develops, the engine may run rough, lose 
power and may stall. This temporary condition can be

Pump 

Switch

Pump 

Knob

Содержание HOT Series

Страница 1: ...Washer ELY RIA OHI O U S A MODELS HOT 2 11024D 1 109 095 0 HOT 2 15024D 1 109 096 0 HOT 2 11026D 1 109 093 0 HOT 2 15026D 1 109 094 0 HOT 3 11024D 1 109 097 0 HOT 3 30036D 1 109 100 0 HOT 4 20024A 1...

Страница 2: ...2 Landa HOT Series Operator s Manual 8 917 208 0 B Machine Data Label...

Страница 3: ...3 Thermal Pump Protection 13 Cleaning Tips 13 Rinsing 13 Shutting Down Clean up 14 Storage 14 Engine Maintenance 14 Maintenance Preventative Maintenance 15 Unloader Valves 15 Winterizing Procedure 15...

Страница 4: ...s When placing an order for parts the machine model and machine serial number are important Refer to the MACHINE DATA box which is filled out during the installation of your machine The MACHINE DATA b...

Страница 5: ...r with the controls 3 Stay alert watch what you are doing 4 All installations must comply with local codes Contact your electrician plumber utility company or the selling dealer for specific details I...

Страница 6: ...c or abrasive fluids to pass through the pump 9 Never run pump dry or leave spray gun closed longer than 1 2 minutes 10 Keep operating area clear of all persons and animals WARNING High pressure spray...

Страница 7: ...fied in this manual 16 Inlet water must be clean fresh water and no hotter then 90 F WARNING Risk of asphyxiation Use this product only in a well ventilated area AVERTISSEMENT Risque d asphyxie Utilis...

Страница 8: ...Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 Pump S...

Страница 9: ...and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans AVERTISSEMENT viter les petites superficies ou les surfaces proximit des ventilateurs d extr...

Страница 10: ...ar back If detergent is to be applied insert a detergent injector Insert quick coupler onto discharge nipple and secure by pushing quick coupler collar forward STEP 5 Release the coupler collar and pu...

Страница 11: ...g water to flush through the system until clear Turn pump switch ON or turn knob to pump position When a steady stream of water flows from the spray gun and wand the machine is ready for the high pres...

Страница 12: ...e must be inserted at end of wand to obtain high pressure Variable Pressure Wand Assembly Models using variable pressure wands grip spray gun securely Turn variable pressure control handle counter clo...

Страница 13: ...tion and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surfa...

Страница 14: ...s CAUTION Failure to follow the above directions will result in damage to your pressure washer ATTENTION Le non respect des directives ci dessus entra nera des dommages la laveuse pression When the pr...

Страница 15: ...tested at the factory before shipping Tampering with the factory setting may cause personal injury and or property damage and will void the manufacturer s warranty Winterizing Procedure Damage due to...

Страница 16: ...ustration Ignition Circuit Periodically inspect wires spring contact and elec trodes for condition security and proper spacing Transformer test CAUTION 10 000 VOLTS use defect free insulated screwdriv...

Страница 17: ...urn air shutter halfway back to the black smoke position previously noted Tighten locking screws If the desired position cannot be obtained using only the air shutter lock the air shutter in as close...

Страница 18: ...enance Schedule Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean Burner Filter Annually Remove Burner Soot From He...

Страница 19: ...on coils not allowing heat transfer Clean coils Lime deposits on inside of coil Delime coil WATER TEMPERATURE TOO HOT Defective high limit switch Replace Insufficient water supplied Check water G P M...

Страница 20: ...lves Check and clean if necessary Worn bearings Check and clean if necessary PRESENCES OF WATER IN OIL Oil seal worn Check and replace if necessary High humidity in air Check and change oil twice as o...

Страница 21: ...an as required Improper electrode setting Clean and test according to diagram in Operators Manual Fuel not reaching combustion chamber Check fuel pump for proper flow Check solenoid flow switch on mac...

Страница 22: ...8 917 208 0 Printed in U S A...