background image

7

Safety

WARNING: In the event of a pilot outage, wait at 
least five minutes to clear out any gas before 
relighting.

AVERTISSEMENT: En cas de panne de la veilleuse, 
attendre au moins cinq minutes pour permettre au 
gaz de se dissiper avant de rallumer.

8. Keep operating area clear of all persons.

WARNING: High pressure spray 
can cause paint chips or other 
particles to become airborne and 
fly at high speeds. To avoid 
personal injury, eye, hand and 
foot safety devices must be worn.

AVERTISSEMENT: Un jet haute 
pression peut écailler la peinture 
ou provoquer l'émission d'autres 
particules dans l'air et leur projec-

tion à hautes vitesses. Pour éviter les lésions 
corporelles, une protection des yeux, du visage, 
des mains et des pieds doit être portée lors de l'util-
isation de cet équipement

9. Always wear properly rated eye protection such as 

safety goggles or face shield while spraying. 

(Safety glasses do not provide full protection)

WARNING: Risk of injury. Hot 
surfaces can cause burns. Use 
only designated gripping areas of 
spray gun and wand. Do not place 
hands or feet on non-insulated 
areas of the pressure washer.

AVERTISSEMENT: Risque de bles-
sures. Les surfaces chaudes 
peuvent causer des brûlures. 

Utiliser uniquement les zones de prise désignées 
du pistolet pulvérisateur et de la lance. Ne pas 
placer les mains ou les pieds sur des endroits non 
isolés de la laveuse à pression

10. To reduce risk of injury, close supervision is 

necessary when a machine is used near children. 
Do not allow children to operate pressure washer. 

This machine must be attended during opera-

tion.

WARNING: Grip cleaning wand 
securely with both hands before 
starting. Failure to do this could 
result in injury from a whipping 
wand.

AVERTISSEMENT: Agripper la lance de nettoyage 
avec les deux mains avant de commencer. Le non-
respect de cette consigne pourrait mener à des 
blessures causées par le mouvement violent de la 
lance

11. Never make adjustments on machine while in 

operation.

12. Be certain all quick coupler fittings are secured 

before using pressure washer.

WARNING: High pressure 
developed by these machines will 
cause personal injury or 
equipment damage. Keep clear of 
nozzle. Use caution when oper-
ating. Do not direct discharge 
stream at people or animals, or 
severe injury or death will result. 

AVERTISSEMENT: La haute 
pression générée par ces 

machines causera des lésions corporelles ou des 
dommages à l'équipement. Se tenir à l'écart de la 
buse. Faire preuve de prudence lors de l'utilisation. 
Ne pas décharger directement le jet vers des 
personnes ou des animaux, car cela risquerait de 
causer des blessures graves ou même la mort.

WARNING: Protect machine from 
freezing.

AVERTISSEMENT: Protéger la 
machine contre le gel.

13. To keep machine in best 

operating conditions, it is 
important you protect machine 
from freezing. Failure to protect 
machine from freezing could 

cause malfunction of the machine and result in 
death, serious bodily injury, and/or property 
damage. Follow storage instructions specified in 
this manual.

DANGER: Risk of asphyxiation. 
Use this product only in a well 
ventilated area. 

DANGER: Risque d'asphyxie. Ne 
pas inhaler les vapeurs.

14. Avoid installing machines in 

small areas or near exhaust 
fans. Adequate oxygen is 
needed for combustion or 

dangerous carbon monoxide will result.

Landa ENG Operator’s   9.801-511.0 - F

WARNING

RISK OF INJURY. 

HOT SURFACES 

CAN CAUSE BURNS

WARNING

TRIGGER GUN KICKS 

 BACK —  HOLD WITH 

        BOTH HANDS

WARNING

RISK OF INJECTION 

OR SEVERE INJURY

TO PERSONS. KEEP 

CLEAR OF NOZZLE.

WARNING

PROCTECT FROM

FREEZING

WARNING

    USE PROTECTIVE 

  EYE WEAR 

AND CLOTHING

WHEN OPERATING

 THIS EQUIPMENT.

DANGER

RISK OF 

ASPHYXIATION. 

USE THIS PRODUCT 

ONLY IN A WELL 

VENTILATED AREA.

Содержание ENG Series

Страница 1: ...ater Electric Powered Natural Gas or LP Heated Operator s Manual Pressure Washer MODELS ENG4 2000 ENG4 2200 ENG4 3000 ENG5 2300 ENG5 3000 ENG6 3200 ENG8 3200 ENG10 3000 For the Landa Dealer nearest yo...

Страница 2: ...ight is on it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the...

Страница 3: ...5 Propane Tank Disposal 15 Exhaust Stack 16 Water Source 17 Installations Above 2000 ft 18 Gas Valve Replacement 18 Assembly Instructions 21 Operating Instructions 22 Applying Detergent General Operat...

Страница 4: ...ous or unsafe practices of the machine Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize...

Страница 5: ...h the operator in the operator s native language by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufa...

Страница 6: ...mise la masse DANGER Keep wand hose and water spray away from electric wiring or fatal electric shock may result AVERTISSEMENT Garder la lance le boyau et le jet d eau l cart de tout c blage lectriqu...

Страница 7: ...de nettoyage avec les deux mains avant de commencer Le non respect de cette consigne pourrait mener des blessures caus es par le mouvement violent de la lance 11 Never make adjustments on machine whil...

Страница 8: ...g space This equipment incorporates parts such as snap switches or similar parts that tend to produce arcs or sparks Therefore when located in a garage it should be in a room or enclosure provided for...

Страница 9: ...n appliance 5 Check all tank and the line connections periodically to be sure they are tight When testing for leaks use approved leak detector solution not matches 6 Make certain your container is pro...

Страница 10: ...802 019 0 1 NIPPLE 3 4 X 2 BLACK 2 8 717 747 0 1 REGULATOR R622CFF FOR R932 28 R932462 3 8 717 746 0 1 REGULATOR HI PRESSURE R321H22 4 8 711 855 0 1 HOSE 1 2 X 19 PROPANE 5 8 717 782 0 1 FITTING PIGTA...

Страница 11: ...ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WEA R AND CLO THIN G MUS T BE WO RN...

Страница 12: ...Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 3 8 QC Nipple 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft diverter sho...

Страница 13: ...Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 3 8 QC Nipple 31 77 64 00 26 91 26 91 Water In 3 4 GHF Exhaust...

Страница 14: ...les petites superficies ou les surfaces proximit des ventilateurs d extraction Gas Codes Confer with local gas company and with proper municipal officials regarding any specific code or regu lations g...

Страница 15: ...etected by the growth of bubbles If bubbles grow tighten or repair the connection as needed Repeat leak test until problem is corrected Check all tank and the line connections periodically to be sure...

Страница 16: ...local codes In the absence of local codes refer to National Fuel Gas Code NFPA 54 and be constructed of materials approved by the Uniform Building Code Vents penetrating ceilings or walls should be do...

Страница 17: ...is kinked the machine will run very rough and the burner will not fire Water Connection Connect the high pressure hose by pulling the coupler collar back and then inserting it onto the discharge nipp...

Страница 18: ...process can also be used when turning down the firing rate for high altitude installations above 2000 ft 1 Adjust the gas pressure down 4 for every 1000 ft of elevation Example Recommended firing rate...

Страница 19: ...s or a special body wrench 8 DO NOT allow any flame to impinge on the regulator vent tubing if supplied It may clog and cause gas valve malfunction 9 DO NOT use the gas cock to adjust gas flow 10 If m...

Страница 20: ...ample water supply Have all flammable liquids or gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supply pressure between 6...

Страница 21: ...ng Push coupler collar forward until secure STEP 5 Before installing nozzle turn on the water supply and run machine allowing water to run from the end of the wand until clear Turn off machine STEP 3...

Страница 22: ...s to pass through the pump NOTE Never run pump dry or leave spray gun closed longer than 3 minutes Landa ENG Operator s 9 801 511 0 F O F F O N 8 1 0 1 2 1 4 1 6 0 2 4 6 TACH HO UR TACH HO UR IN STRUC...

Страница 23: ...prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface For best results limit...

Страница 24: ...appareil e RIESGO DE ASFIXIA Use el producto en un area de venti laci n adecuad a RISQUE D ASPH YXIE Utiliser dans un endroit bien a r RISK OF ELECT ROCUT ION Connec t only to properl y ground ed out...

Страница 25: ...essure 2 Detach water supply hose and high pressure hose 3 Turn on the machine for a few seconds until remaining water exits Turn pump off immediately 4 Do not allow high pressure hose to become kinke...

Страница 26: ...minating the unloader from the system and attaching the 50 discharge hose directly to the pump If high pressure is developed in this manner the pump is good and the unloader needs to be repaired or re...

Страница 27: ...gravitate to the floor rather than rise out of the stack Hence adequate floor space and good ventilation are especially important with propane systems Gas Pressure Requirements All propane fired machi...

Страница 28: ...r in the burner jet orifices 1 To Remove Burner Manifold From Water Heater Coil Turn off the gas to the main burner by turning the knob to the OFF position on the gas valve and the main gas supply Dis...

Страница 29: ...63 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number 125 91 Molecular Weight 44 09 58 12 To Calculate...

Страница 30: ...n water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per square inch 125 psi Oil Change Record 1 Water Colu...

Страница 31: ...er severe conditions Maintenance Schedule Replace Fuel Lines Annually Pump Oil 10W 40 Non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean...

Страница 32: ...hly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s Repair hole Strainer basket plugged Remove...

Страница 33: ...w packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve kit Obstruction in spray nozzle Remove obstruction Lea...

Страница 34: ...turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas valve 3 Probe terminals PV and MV PV If 24 volts not...

Страница 35: ...itor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BEFORE THE BURNER SWITCH OR FLOW SWITCH IS TURNED OFF...

Страница 36: ...9 801 511 0 Printed in U S A...

Отзывы: