4

Tower Installation - Single Brand Tower

1. 

Plug ADA harness (PN 52-3734) into ADA panel in front of 

drip tray.

2.  Route all harnesses and syrup/water lines of the tower 

through the opening in the drip tray assembly and through 

opening in tower collar (PN 05-3491).

3.  Place drip tray with collar into counter cutout. 
4.  Guide the tower through the opening in the drip tray and 

position the tower facing forward, with the nozzle above the 

drip tray.

Junction Box Installation

4.  Route ribbon cable, harness, and syrup/water lines through 

the the tower connection nut provided, then thread the nut 

onto the tower and tighten to secure to counter. 

5. 

Connect drain line to drain fitting at drip train and route to 

open type drain.

A

B

D

C

A. Tower

B. Connection Lines

C. Counter

D. Connection Nut

5.  Route tower harnesses and syrup/water lines through the the 

tower connection nut provided, then thread the nut onto the 

tower and tighten to secure to counter. 

6. 

Connect drain line to drain fitting at drip tray and route to 

open type drain.

A

B

C

D

A. Tower

B. Harnesses & Syrup/

    Water Lines

C. Drip Tray

D. ADA Panel

A

B

E

D

C

A. Tower

B. Connection Lines

C. Counter

D. Connection Nut

E. Tower Collar

    (Under Drip Tray)

 

Tower harnesses and syrup/water lines are all 36 

 

inches in length. Placement of the Junction Box must 

be under the counter and within 2 feet (24 inches) of 

the Tower assembly.

NOTE

 

DO NOT install or set junction box on the ground, this 

is a shock hazard.

WARNING

1.  Position the Mounting Bracket of the Junction Box so that 

there is adequate slack for connection lines to accommodate 

sliding the Junction Box forward for service. 

2.  Secure the Mounting Bracket to bottom of the counter with 

four screws provided.

 

Do not over tighten, this can cause damage to the 

 

ceramic lever.

ATTENTION

 

Do not over tighten, this can cause damage to the 

 

ceramic lever.

ATTENTION

3.  Align the Junction Box with the Mounting Bracket, then slide 

box through bracket to secure to counter. 

4. 

If applicable, connect the ADA harness (PN 52-3734), routed 

from ADA panel in drip tray, to extra connecting wire in Tower 

harness (PN 52-3732). 

5. 

Connect the power harness (PN 52-3348) to its appropriate 

connections on the main board in the junction box. 

 

See image below or Wiring Diagram located in 

 

Junction Box or on pages 27 and 28 of this manual for 

 reference.

NOTE

A

B

C

A. Mounting Bracket

B. Screws (4)

C. Bottom of Counter

Содержание UNICORN TOWER

Страница 1: ...e a claim with carrier Responsibility for damage to the dispenser lies with the carrier IMPORTANT SAFETY INSTRUCTIONS The installation and relocation if necessary of this product must be carried out b...

Страница 2: ...of the installer to ensure compliance Water Notice SYRUP SUPPLY Min Pressure 20 PSI 0 137 MPA Max Pressure 70 PSIG 0 482 MPA DIET SYRUP SUPPLY Min Pressure 10 PSIG 0 068 MPA Max Pressure 70 PSIG 0 48...

Страница 3: ...NTION 2 Select a location that utilizes the clearances space required for installation 3 Select a location for the remote chiller system or carbonator if nessesary syrup pumps CO2 tank syrup container...

Страница 4: ...Panel A B E D C A Tower B Connection Lines C Counter D Connection Nut E Tower Collar Under Drip Tray Tower harnesses and syrup water lines are all 36 inches in length Placement of the Junction Box mu...

Страница 5: ...hiller system to the syrup inlet at junction box Repeat for all syrup connections 7 Route appropriate tubing from the water outlet at remote chiller to the water inlet at junction box Repeat for retur...

Страница 6: ...metric Programmer C Toggle 3 Select the valve to program by adjusting the toggle on the Selector Board 4 Press red mem to read the valve ratio setting in memory 5 Press carb toggle button to choose be...

Страница 7: ...r to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough...

Страница 8: ...and flush out product remaining in the lines 4 Prepare Cleaning Solution described above 5 Place product lines with BIB connectors into cleaning solution 6 Activate each valve until lines are filled...

Страница 9: ...9 WIRING DIAGRAM LFCV...

Страница 10: ...10 WIRING DIAGRAM VV...

Страница 11: ...11 COUNTER CUTOUT NOT TO SCALE...

Страница 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: