Tower Installation - Single Brand Tower
1.
Plug ADA harness (PN 52-3734) into ADA panel in front of
drip tray.
2. Route all harnesses and syrup/water lines of the tower
through the opening in the drip tray assembly and through
opening in tower collar (PN 05-3491).
3. Place drip tray with collar into counter cutout.
4. Guide the tower through the opening in the drip tray and
position the tower facing forward, with the nozzle above the
drip tray.
Junction Box Installation
4. Route ribbon cable, harness, and syrup/water lines through
the the tower connection nut provided, then thread the nut
onto the tower and tighten to secure to counter.
5.
Connect drain line to drain fitting at drip train and route to
open type drain.
A
B
D
C
A. Tower
B. Connection Lines
C. Counter
D. Connection Nut
5. Route tower harnesses and syrup/water lines through the the
tower connection nut provided, then thread the nut onto the
tower and tighten to secure to counter.
6.
Connect drain line to drain fitting at drip tray and route to
open type drain.
A
B
C
D
A. Tower
B. Harnesses & Syrup/
Water Lines
C. Drip Tray
D. ADA Panel
A
B
E
D
C
A. Tower
B. Connection Lines
C. Counter
D. Connection Nut
E. Tower Collar
(Under Drip Tray)
Tower harnesses and syrup/water lines are all 36
inches in length. Placement of the Junction Box must
be under the counter and within 2 feet (24 inches) of
the Tower assembly.
NOTE
DO NOT install or set junction box on the ground, this
is a shock hazard.
F
WARNING
1. Position the Mounting Bracket of the Junction Box so that
there is adequate slack for connection lines to accommodate
sliding the Junction Box forward for service.
2. Secure the Mounting Bracket to bottom of the counter with
four screws provided.
Do not over tighten, this can cause damage to the
ceramic lever.
!
ATTENTION
Do not over tighten, this can cause damage to the
ceramic lever.
!
ATTENTION
3. Align the Junction Box with the Mounting Bracket, then slide
box through bracket to secure to counter.
4.
If applicable, connect the ADA harness (PN 52-3734), routed
from ADA panel in drip tray, to extra connecting wire in Tower
harness (PN 52-3732).
5.
Connect the power harness (PN 52-3348) to its appropriate
connections on the main board in the junction box.
See image below or Wiring Diagram located in
Junction Box or on pages 27 and 28 of this manual for
reference.
NOTE
A
B
C
A. Mounting Bracket
B. Screws (4)
C. Bottom of Counter