6.2
Under SOLD OUT
A. Loose connection.
A. Ensure cables are secure.
condition, SOLD OUT
B. Polarity incorrect (cables
B. Looking at terminals (LED away
alarm sounds, but the
crossed).
from you), ensure flat side of the
Red SOLD OUT LED
rectangle (between the terminals) is
does not flash.
at bottom and that the red positive
wire is on the right terminal.
6.3
Unit will not go into
A. Loose connection.
A. Check to ensure cables plugged in
AUTO mode.
correctly.
B. Switch is broken.
B. Replace Switch.
C. Failed PCB.
C. Replace PCB.
6.4
SOLD OUT Alarm does
A. Pressure Switch is ON.
A. 1. Check Syrup supply.
not shut OFF.
2. Check Syrup Bag Line
Connections.
3. Check CO
2
supply.
4. Check for loose connection.
5. Replace pressure switch.
B. Failed PCB.
B. Replace PCB.
6.5
Water not dispensing
A. Water is not on.
A. Check water supply.
from valve.
B. Chiller is clogged or shut OFF. B
Ensure there are no leaks or clogs
in the chiller and that chiller is ON.
6.6
Red light on the circuit
A. Loose connection.
A. Check all connections.
comes on or Green
B. Bad solder joint or failed PCB. B. Replace PCB.
light on the circuit board
does not come on.
6.7
Water leakage around
A. O-ring is not properly installed A. Install or replace o-ring correctly.
nozzle.
above diffuser.
B. O-ring is damaged or missing. B. Replace o-ring.
6.8
Leakage between
A. One or more retaining screws
A. Tighten all six (6) retaining screws.
upper and lower
loose.
bodies.
B. Paddle arm assemblies are
B. Replace paddle arm assemblies.
worn or damaged.
6.9
Miscellaneous leakage.
A. Gap between parts.
A. Tighten appropriate retaining
screws.
B. Damaged, missing, or
B. Replace appropriate o-rings.
improperly installed o-rings.
6.10
Insufficient water flow.
A. Water flowing pressure is
A. 1. Check incoming water from
too low, or restricted.
carbonator to ensure minimum
flowing pressure. See
SPECIFICATIONS.
2. Check stems on mounting
block to ensure it is in fully
OPEN position.
B. Foreign debris in water flow
B. Remove water flow control from
controls.
upper body and clean out any
foreign materials to ensure smooth
free piston movement.
6.11
Insufficient syrup flow.
A. Syrup flowing pressure is
A. 1. Check incoming syrup to
too low, or restricted.
ensure minimum flowing
pressure. See
SPECIFICATIONS.
2. Check shutoff on mounting
block to ensure it is in fully
OPEN position.
B. Foreign debris in syrup
B. Remove syrup flow control from
flow controls.
upper body and clean out any
foreign materials to ensure
smooth free piston movement.
6
TROUBLE
CAUSE
REMEDY