Valve Configuration - Graduated Cylinder Syrup Calibration
1. Tap
Valve Configuration
on the navigation menu.
2. Tap on the syrup valve to be calibrated.
3. Adjust the desired dispense amount to 50 ml using the +/-
buttons in the Calibrate Syrup pane.
4. With the graduated cylinder placed in a position below
the nozzle, tap the Start button. The unit will dispense the
designated syrup amount.
5. Examine the dispensed volume in the graduated cylinder.
If the dispensed volume does not match the value of 50 ml,
use a screwdriver to adjust the brand syrup flow control.
(See Plumbing Diagram on page 44 for reference).
6. Repeat steps 4 and 5 until the designated volume of 50 ml
is achieved.
7. Repeat steps 2 - 6 for the remaining brand syrup modules.
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
Fill to 50 ml
Graduated Cylinder
The water flow rate was set to 73.93 ml/sec, which
makes the final syrup flow rate 14.79 ml/s. The finished
drink flow rate dispensed will be 88.72 ml/s.
NOTE
Le débit de sirop est déterminé par le débit de la
source d’eau et le rapport de sirop sélectionné (par
exemple, 5,00:1).
REMARQUE
Syrup flow rate is determined by water source flow
rate and selected syrup ratio (e.g., 5.00:1).
NOTE
Le débit d’eau a été réglé à 73,93 ml/s, ce qui fait que
le débit de sirop final est de 14,79 ml/s. Le débit de
boisson fini distribué sera de 88,72 ml/s.
REMARQUE