Содержание DELTA III PRE-MIX

Страница 1: ...thout legs 25 1 2 inches 648 mm WEIGHT Shipping 170 pounds 77 1 kg Empty 146 pounds 66 2 kg Operating 220 pounds 99 8 kg ICE BANK WEIGHT 27 pounds 12 25 kg WATER BATH CAPACITY 10 87 gallons 41 15 liters COMPRESSOR 1 3 HP Tecumseh 115V 60Hz AGITATOR MOTOR 25W 115V CONDENSER MOTOR 9W 115V ICE BANK CONTROL Lancer Electronic Ice Bank Control EIBC TRANSFORMER 120V Primary 24V Secondary Optional 230V 50...

Страница 2: ...T WINDING 4 4 8 COMPRESSOR STARTS AND RUNS A SHORT TIME BUT SHUTS OFF ON OVERLOAD 4 4 9 WARM DRINKS 5 5 ILLUSTRATIONS PARTS LIST AND WIRING DIAGRAMS 7 5 1 COMPRESSOR DECK ASSEMBLY 7 8 5 2 DECK ASSEMBLY 9 10 5 3 CABINET ASSEMBLY 11 12 5 4 TUBING ASSEMBLY 13 14 5 5 CONTROL HOUSING 15 16 5 6 WIRING DIAGRAM 17 i INSTALLATION INSTRUCTIONS KIT INSTALLATION 6 VALVE PREMIX FIGAL 1 INSTALLATION PROCEDURES ...

Страница 3: ...7 Disconnect Gas 6 1 4 Inch 8 17 0018 Disconnect Liquid 6 1 4 Inch Item Part No Description Quantity 82 1265 06 Kit Installation 6 Valve Premix Metric 1 18 0267 01 01 Regulator Assy 1 Tank Mount Metric 2 05 0011 Flare Seal 1 4 Inch 1 3 01 0221 Stem 1 4 Inch 1 4 01 0222 Nut Swivel 1 4 Inch 1 5 07 0437 Clamp 1 4 Inch 24 6 08 0349 Tubing 1 4 Inch AR 7 17 0017 Disconnect Gas 6 1 4 Inch 8 17 0018 Disco...

Страница 4: ...upported surface capable of supporting a minimum weight of 250 pounds 113 6 kg It may be either counter or leg mounted NOTE NSF listed units must be sealed to the counter or have four 4 inch legs installed B When the dispenser is to be permanently bolted to the counter top seal dispenser base to counter top with a bead of clear silicone caulk or sealant which provides a smooth and easily cleaned b...

Страница 5: ...OTE Units equipped with an electronic ice bank control contain a five 5 minute delay Compressor will not begin running until five 5 minutes after unit is energized 1 7 CONNECTING TO PRODUCT SUPPLY see Page ii A Using proper beverage tubing and fittings connect to product inlet with a clamp PN 07 0437 B Mark syrup tube assemblies with product ID tape C Route through cutout in counter or through acc...

Страница 6: ...ates the rinse water is free of residual detergent F Fill the lines with a low pH 7 0 chlorine solution containing at least 50 PPM 50 mg L chlorine Make sure that lines are completely filled and allow to stand for ten 10 minutes G Reconnect syrup containers and ready Unit for operation H Draw drinks to refill lines and flush the chlorine solution from the dispenser NOTE Please note that a fresh wa...

Страница 7: ...age A Measure voltage across common start but hums and run terminal on compressor Voltage must not drop below 90 of rated voltage B Incorrect wiring B Refer to wiring diagram and correct C Starting relay malfunctioning C Replace starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure D Compressor malfunctioning D Replace compressor 4 7 Compressor star...

Страница 8: ...hrough grill B Refrigeration system not B Refer to Sections 4 11 4 15 running C Refrigerant leak C Repair and recharge D Condenser fan motor not D Replace condenser fan motor working E Dirty condenser E Clean condenser F Dispenser capacity exceeded F Add pre cooler or replace with larger dispenser NOTES TROUBLE CAUSE REMEDY https appliancetechmanuals com ...

Страница 9: ...6 NOTES https appliancetechmanuals com ...

Страница 10: ...A 3 2 3 4 19 6 7 5 45 1 9 15 12 11 10 41 12 16 18 8 48 42 43 17 17A 17B 17C 17F 17G 17E 17D 13 37 25 21 24 44 20 20A 22 23 20B 20D 20C 20E 20F 26 29 27 FROM FROM EVAPORATOR EVAPORATOR 30 28 40 5 ILLUSTRATIONS PARTS LISTS AND WIRING DIAGRAMS 5 1 REFRIGERATION DECK ASSEMBLY 7 https appliancetechmanuals com ...

Страница 11: ... 1 3 hp 240 220V 50Hz 20b 04 1010 Screw Brass 6 32 X 0 250 20c 12 0339 Overload 115V 60Hz 12 0290 Overload 230V 50Hz 12 0253 Overload 220V 60Hz 20d 12 0005 Relay 115V 60Hz 12 0031 Relay 230V 50Hz 12 0028 Relay 220V 60Hz 20e 13 0066 Cover Terminal 20f 03 0040 Bale Strap 20g 03 0041 Spring Overload Not Shown 20h 12 0260 Start Capacitor 220V 60Hz Not Shown ITEM PART NO DESCRIPTION 8 21 02 0114 Gromme...

Страница 12: ...5 2 DECK ASSEMBLY 9 WATER BATH FILL HOLE IM PORTANT FILL WATER BATH UNTIL TANK OVERFLOW TUBE WATER FLOWS FROM 3 4 1 2 5 6 https appliancetechmanuals com ...

Страница 13: ...6 0856 Label Water Fill 3 04 0431 Screw 1 4 20 x 1 250 Round Head 4 04 0033 Washer 1 4 5 30 5891 01 Plate Carbonator No Carbonator 6 50 0254 01 Insulation Carbonator Deck No Carbonator 5 2 DECK ASSEMBLY CONTINUED 10 https appliancetechmanuals com ...

Страница 14: ...27 28 29 30 25 26 25 24 31 5 23 1 22 21 20 5 16 15 14 2 5 10 9 6 7 3 4 11 12 13 18 5 19 5 19 18 17 8 32 33 REF REF REF REF REF 5 3 CABINET ASSEMBLY 11 https appliancetechmanuals com ...

Страница 15: ...7 01 Bracket Leg 19 81 0112 Leg Plastic 20 07 0405 Plug Key Switch 21 12 0097 Key Switch Includes Nut 22 06 0881 Label Key Switch 23 07 0347 Plate Cover 24 REF Tank Assy 42 0057 Tank Assy 42 0058 Tank Assy LF Sol 25 50 0151 Insulation Tank Side 26 50 0150 Insulation Tank Back 27 50 0248 Insulation Tank Front 28 06 0632 Label WARNING 29 REF Bonnet Assy 82 2764 Bonnet Assy Contact Customer Service f...

Страница 16: ...1 2 3 5 6 7 8 9 4 12 10 13 14 11 15 5 4 TUBING ASSEMBLY 13 https appliancetechmanuals com ...

Страница 17: ... 5V 6 48 0759 Tube Assy Prod 5 4 3 6V 5V 7 48 0761 Tube Assy Prod 3 6V 8 48 0762 Tube Assy Prod 2 Pre Delta 9 48 1494 Tube Assy 1 Pre Mix 10 48 1495 Tube Assy 6 Pre Mix 11 01 1831 Spacer 10 24 Threaded 12 30 6807 Spacer Lower Water Cage 13 30 6767 Brace Water Coils 14 04 0116 Screw 10 24 x 0 625 PHD PH SS R1 05 1932 Fitting Adapter 7 16 MF x 1 2 MF R in margin indicates change or revision 5 4 TUBI...

Страница 18: ...F2 2AG HS1 HYBRID MODULE C2 RLY 2 U1 VR1 J1 _ 1 BR1 1 J2 1 J3 RLY 1 1 NO TIME C5 R1 C4 J5 MADE IN U S A J4 18 17 16 15 14 13 12 19 12 20 1 2 3 4 5 6 7 8 9 10 11 5 5 CONTROL HOUSING 15 https appliancetechmanuals com ...

Страница 19: ...d Assy EIBC 7 12 0190 Terminal Block 8 04 0477 Screw 8 32 x 0 375 9 04 0504 Screw 8 16 x 0 375 10 30 5108 01 Cover Control Box 11 11 0186 Jumper 4 Position 12 13 0059 Bushing 13 13 0028 Strain Relief 14 52 1219 Power Cord Pigtail 15 52 0904 Harness Assy Trans 1 16 52 0905 Harness Assy Trans 2 17 52 0906 Harness Assy Comp 1 18 52 0907 Harness Assy Comp 2 19 11 0008 Tie Wrap 20 12 0089 Switch R in m...

Страница 20: ...PACITOR CARBONATOR MOTOR LABEL WIRING DIAGRAM 06 2221 RIBBED BLK FAN MOTOR B W G W B 3 G 1 2 12 4 11 3 W 10 9 1 B B W B W B 1 4 B W B W B G COMPRESSOR J3 TERM2 PCB IBC TERM3 B J2 OUT IN IN TERM1 B B J4 OUT B R G B R G W B G B W G R B B W CARBONATOR PROBE W TO PLAIN WATER VALVE FIELD INSTALLED OPTION 1 WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DELAY BEFORE THE COMPRES...