5. DISPENSER DISPOSAL
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was pur
chased. Comply with local regulations regarding disposal of the refrigerant and
insulation.
TROUBLE
CAUSE
REMEDY
4.16 Compressor and Condenser Fan
Motor will not start after five (5) minute
Power Off Delay
(Lancer EIBC Export
only)
A. Transformer tripped.
B. Relay will not turn on compressor
C. Probe unplugged
D. Improper wiring
E. Damaged electronics
A. Reset transformer.
B. Failed relay. Replace Control Board.
C. Check probe connection at PCB
D. Check Power Indicator Lamp; check
wiring per Wiring Diagram
E. Replace Control
4.17 Warm Drinks
A. Restricted airflow
B. Dispenser connected to hot water
supply.
C. Refrigeration system not running.
D. Refrigeration leak.
E. Condenser fan motor not working.
F. Dirty Condenser.
G. Dispenser capacity exceeded.
A. Check clearances around sides, top,
and inlet of unit. Remove objects blocking
airflow through grill.
B. Switch to cold water supply.
C. Refer to Sections 4.11 - 4.15.
D. Repair and recharge.
E. Replace condenser fan motor.
F. Clean condenser.
G. Add pre-chiller.
6. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS
6.1 INSTALLATION KITS AND OPTIONAL ACCESSORIES
A. PART NUMBER
DESCRIPTION
82-1796
BIB INSTALLATION KIT - FOR 3/8 INCH SYRUP INLETS
82-1795
BIB INSTALLATION KIT - FOR 1/4 INCH SYRUP INLETS
82-2613-04
FIGAL INSTALLATION KIT - 4 VALVE - FOR 3/8 INCH SYRUP
INLETS
82-0221-04
FIGAL INSTALLATION KIT - 4 VALVE - FOR 1/4 INCH SYRUP
INLETS
82-2480
SPLASH PLATE RETROFIT KIT (ADAPTS NEW SPLASH PLATE,
PN 30-6746, TO OLDER MODELS)
82-1799
24VAC LIGHTED MARQUEE (GRAPHICS ORDERED
SEPARATELY)
82-2570
ELS MARQUEE KIT (GRAPHICS INCLUDED)
B. MARQUEE GRAPHICS FOR PN 82-1799 ONLY
PART NUMBER
DESCRIPTION
06-1794
COCA-COLA DYNAMIC RIBBON, SCREENED
06-1793
COCA-COLA THREE CUP, “TASTE REAL REFRESHMENT”,
DURATRANS
06-1798
CHILLED JUICE BEVERAGES, DURATRANS
19