lancer 500 Series Скачать руководство пользователя страница 10

1.  INSTALLATION

 

1.1  RECIEVING THE UNIT

 

 

Each unit is completely tested under operating conditions and thoroughly inspected before ship-

ment. At time of shipment, the carrier accepts the unit and any claim for damage(s) must be made 

with carrier. Upon receiving units from the delivering carrier, carefully inspect carton for visible 

indication(s) of damage. If damage exists, have carrier note same on bill of lading and file a claim 

with the carrier.

 

1.2  UNPACKING

WARNING

  To avoid personal injury or damage, do not attempt to lift a unit without help. For heavier units, use of 

a mechanical lift may be appropriate. Units are equipped with automatic agitation. The unit may activate unexpect-

edly. Do not place hands, or foreign objects into the ice storage compartment. Unplug dispenser from the power 

source , when unit is being serviced, cleaned, or sanitized.

WARNING

 FAILURE TO MAINTAIN PROPER AIR CLEARANCE WILL CAUSE THE COMPRESSOR TO 

OVERHEAT AND WILL RESULT IN PREMATURE COMPONENT FAILURE 

WARNING

 FALTA DE MANTENIMIENTO DE LIQUIDACIÓN DE AIRE ADECUADO HACEN QUE EL COM-

PRESOR SE SOBRECALIENTE Y PODRÁ FALLAR COMPONENTE PREMATURO

WARNING

 NON-RESPECT DE LIQUIDATION DE L’AIR BONNE que le compresseur à surchauffer et à EN-

TRAÎNER DE DURER COMPOSANT

ADVERTENCIA  

Evite las lesiones personales, no trate de levantar el dispensador sin ayuda. Para los dispen-

sadores màs pesados use un elevador mecánico. Las unidades equipadas con agitación automática se activan 

repentinamente. No ponga las manos ni objetos extranos en el compartimiento de almacenamiento de hielo. Des-

enchufe el dispensador durante tareas de servicio, limpieza y esterilización.

!

 AVERTISSEMENT 

Pour éviter des blessures ou des dommages, n’essayez pas de soulever une unité sans 

aide. Pour les unités plus lourdes, l’utilisation d’un ascenseur mécanique peut être appropriée. Les unités sont 

équipées d’une agitation automatique.

L’unité peut s’activer demainére inattendue. Ne placez pas les mains, ou des corps étrangers dans le comparti-

ment de stockage de glace. Débranchez le distributeur de la source d’alimentation en électricité quand l’unité est 

entretenue, nettoyée ou aseptisée.

 

 

A.  Remove cup rest by lifting out.

 

 

B.  Remove splash plate by pulling forward at the bottom.  Drip tray can be removed before 

 

 

 

removing splash plate.

 

 

C.  Remove drip tray by lifting out.

 

 

D.  Remove shipping base.  

DO NOT LAY UNIT ON ITS SIDE OR BACK.  DO NOT USE DRIP  

 

TRAY FRAME FOR A HANDLE.

 

 

NOTE:

 If unit is to be transported, it is advisable to leave unit secured to plywood shipping base.

 

 

E.  Inspect unit for concealed damage.  If damage exists, notify delivering carrier note and file a  

 

claim against the carrier.

 

1.3  INSTALLATION

 

 

The dispenser is designed to sit on a flat, supported surface capable of supporting a minimum 

weight of 200 pounds (90.7 kg).  It may be either counter or leg mounted.  When the dispenser is to 

be permanently bolted to the counter top, seal dispenser base to counter top with a silicone sealant 

which provides a smooth and easily cleanable bond to the counter.

 

 

NOTE:

 NSF listed units must be sealed to the counter or have four (4) inch legs installed.

10

 

 

Locate dispenser to allow approximately 15 inches (380 mm) of unobstructed space above and 

 

 

six (6) inches (152 mm) of unobstructed space in back of the unit for proper air circulation and 

 

 

removal of bonnet.  Air is drawn in through the back grill and is exhausted out the top grill.

 

 

A.  Position dispenser on counter.

 

 

B.  Remove bonnet from the dispenser.

 

 

C.  Remove insulation strip from in front of refrigeration deck.  Fill tank with water until water comes  

 

out of overflow tube.  Replace insulation. Use bottled water where a water problem exists.

Содержание 500 Series

Страница 1: ...rt 800 729 1550 Email custserv lancercorp com www lancercorp com Manual PN 28 0063 06 NOVEMBER 10 2014 FOR QUALIFIED INSTALLER ONLY Counter Electric Dispenser Lancer Series 500 Operation Manual PN 28...

Страница 2: ...1 1 RECIEVING THE UNIT 10 1 2 UNPACKING 10 1 3 INSTALLATION 10 1 4 CONNECTING TO ELECTRICAL POWER 11 1 5 CONNECTING TO WATER SUPPLY 11 1 6 CONNECTING TO CO2 12 1 7 CONNECTING TO BAG IN BOX BIB SYRUP...

Страница 3: ...MPRESSOR STARTS AND RUNS A SHORT TIME BUT SHUTS OFF ON OVERLOAD 18 4 16 COMPRESSOR AND CONDENSER FAN MOTOR WILL NOT START AFTER FIVE 5 MINUTE POWER OFF DELAY LANCER EIBC EXPORT ONLY 19 4 17 WARM DRINK...

Страница 4: ...C 50 60Hz 2 6AMPs WEIGHT Empty 89 lbs 40 4 kg Operating 125 lbs 55 4 kg Shipping 108 lbs 49 0 kg ICE Capacity 16 lbs 17 26 kg FITTINGS Water for carbonator inlet 3 8 barb Plain water inlet 3 8 barb Br...

Страница 5: ...Clamps Fittings Water Booster Water Regulator Precision Cutters if removing replacing carbonator tank CONSIDER LOCATION OF THE FOLLOWING PRIOR TO INSTALL Water supply lines Drain Is the countertop le...

Страница 6: ...supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere la unidad por...

Страница 7: ...ador de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la corri...

Страница 8: ...ques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres app...

Страница 9: ...nd local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo me...

Страница 10: ...ever une unit sans aide Pour les unit s plus lourdes l utilisation d un ascenseur m canique peut tre appropri e Les unit s sont quip es d une agitation automatique L unit peut s activer demain re inat...

Страница 11: ...a built in carbonator disconnect the power supply to the carbonator motor by disconnecting the designated connector located near the top of the electrical control box on the refrigeration deck B Chec...

Страница 12: ...owing the manufacturer s instructions 1 8 PURGING THE CARBONATION SYSTEM A Turn on water source Lift the black lever on the top of the carbonator tank relief valve until water flows from the holes in...

Страница 13: ...ONTROL WATER Increase Decrease 1 11 ADJUSTING WATER TO SYRUP RATIO BRIX LEV A Hold the Lancer brix cup under the syrup separator and activate valve Check brix B To obtain the proper brix use screwdriv...

Страница 14: ...en recommendations and safety guidelines The solution must provide 100 parts per million PPM chlorine e g Sodium Hypochlorite or bleach A minimum of five gallons of sanitizing solution should be prepa...

Страница 15: ...d with warm water and cloth or with the nozzle brush supplied Wipe off dispensing lever D Wearing sanitary gloves remove drain and air dry the nozzle and diffuser E Wearing sanitary gloves replace dif...

Страница 16: ...ontrol A Verify incoming supply water pressure is a minimum of 35 PSI 2 4 BAR B Open shutoff fully C Remove water flow control from upper body and clean out any foreign material to ensure smooth free...

Страница 17: ...water or syrup flow C Kinked line A Open shutoff fully B Remove valve from mounting block open shutoffs slightly and check water and syrup flow If no flow check dispenser for freeze up or other probl...

Страница 18: ...nd correct C Replace starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure D Replace compressor 4 14 Compressor starts but does not switch off start wi...

Страница 19: ...ing F Dirty Condenser G Dispenser capacity exceeded A Check clearances around sides top and inlet of unit Remove objects blocking airflow through grill B Switch to cold water supply C Refer to Section...

Страница 20: ...6 2 CABINET ASSEMBLY 9 4 1 2 22 6 7 8 16 22 11 21 23 24 10 14 12 13 17 3 27 18 15 22 5 24 25 26 16 15 22 19 20 20...

Страница 21: ...nt Plate Chiller 14 30 6612 Splash Plate Extended No Drip Tray 15 51 0494 01 Support Leg 16 81 0112 Leg Adjustable 17 04 0529 Screw 8 32 x 0 750 18 08 0100 Tubing 19 12 0097 Keylock Switch Optional 20...

Страница 22: ...6 3 COMPRESSOR DECK ASSEMBLY 2 4 4 7 3 6 5 29E 29B 29D 29C 29A 23 16 22 17 27 28 20 30A 30B 30C 6 30 18 13 9 4 31 14 31 10C 10A 10D 10B 19 8 1 4 24 29 10 21 12 32 26 25 11 15 33 34 22...

Страница 23: ...VA 18 03 0150 Retainer Clip Compressor 19 03 0028 Retainer Clip Evaporator Coil 20 06 0431 Label 115V 60Hz 1 4 HP 06 0461 Label 230V 50Hz 1 4 HP 06 0744 Label 240V 60Hz 1 4 HP 21 47 0746 02 Low Side T...

Страница 24: ...120 AC JCT AGITATOR MOTOR 24V LEADS TRANSFORMER LANCER ICE BANK CONTROL PROBE RELAY FAN MOTOR COMPRESSOR OVERLOAD C M S L M S LABEL WIRING 500 2500 CED 06 0031 01 WHEN STARTING UNIT OR IF CURRENT IS I...

Страница 25: ...RE IS A FIVE 5 MINUTE DELAY BEFORE THE COMPRESSOR FAN STARTS IMPORTANT 06 2093 USED ON PN 82 2665 230V 50HZ AND PN 82 2666 240V 60HZ GREEN BLACK WHITE JCT 220 240V 50 60HZ AC FAN MOTOR COMPRESSOR OVER...

Страница 26: ...LANCER To order parts call Customer Service 800 729 1500 Warranty 800 729 1550 Email custserv lancercorp com www lancercorp com...