background image

 

 

N.   Fill a tank with sanitizing solution. Connect syrup line to the tank. Connect CO2 supply hose to

 

 

 

tank and pressurize.

 

 

O.   Remove dispensing valve nozzle (twist and pull down) and pull out center mixing baffle. Using

 

 

 

a plastic bristle brush and detergent soap solution scrub the nozzle, mixing baffle, bottom of

 

 

 

dispensing valve, and cup lever. Rinse with clean water.

 

 

P.   Reassemble mixing baffle and nozzle.

 

 

Q.   Place waste container under applicable dispensing valve. Activate valve and draw sanitizing

 

 

 

solution through line for a minimum of 60 seconds. This will ensure line is flushed and filled with

 

 

 

sanitizing solution. Allow line to stand for at least 30 minutes.

 

 

R.   Disconnect CO2 supply hose from the tank.

 

 

S.   Reconnect syrup lines to syrup containers (for example, quick disconnects, figal containers,  

 

etc.) and ready unit for operation.

!

CAUTION

 FOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO 

NOT USE A FRESH WATER RINSE. THIS IS A NSF REQUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE 

SYSTEM CREATES A HEALTH HAZARD.

PRECAUCIÓN

 DESPUÉS DE LA ESTERILIZACIÓN, ENJUAGUE CON EL PRODUCTO FINAL HASTA QUE 

ELIMINAR EL SABOR QUE QUEDA. NO ENJUAGUE CON AGUA FRESCA. ÉSTA ES UNA EXIGENCIA DE NSF. SI 

QUEDA SOLUCIÓN DE ESTERILIZACIÓN EN EL SISTEMA, GENERA UN PELIGRO PARA LA SALUD.

ATTENTION

 DÉFENSE DE RINCER L’OUTIL À L’EAU FRAICHE IMMÉDIATEMENT APRÈS UN TRAITEMENT 

SEPTIQUE.EN CAS DE APRÈS-GOÛT, NE PURGER AVEC LE PRODUIT FINAL UNE EXIGENCE NSF.

 

 

T.   Draw drinks and refill lines with end product to flush sanitizing solution from the dispenser.

 

 

U.   Test dispenser in normal manner for proper operation. Taste dispensed product to ensure there

 

 

 

is no off-taste. If off-taste is found, additional flushing of syrup system may be required.

 

 

V.   Repeat cleaning, rinsing, and sanitizing procedures for each valve/syrup circuit.

 

 

W.  Clean exterior of unit as instructed in Section 2.6.

 

 

X.   Using a spray bottle of sanitizing solution, spray the underside of all dispenser valves, valve

 

 

 

spouts and cup levers. Allow to air dry.

 

 

Y.   Fill ice bin with ice. Install ice bin cover on unit.

  

NOTE: 

Thoroughly rinse inside and outside of syrup tank that was used for sanitizing solution with 

plain water to remove all solution residue.

 

2.4   CLEANING AND SANITIZING BAG-IN-BOX (BIB) SYSTEMS

 

 

A.   Disconnect syrup quick disconnect coupling from syrup packages and connect coupling to a  

 

bag valve removed from an empty Bag-in-Box package.

 

 

B.   Place end of syrup inlet line, with bag valve attached, in a clean container filled with clean,

 

 

 

potable, room temperature water.

 

 

C.   Place waste container under applicable dispensing valve. Activate valve until water is

 

 

 

dispensed. Flush and rinse line and fittings for a minimum of 60 seconds to remove all traces

 

 

 

of residual product.

  

NOTE:

 Extended lengths of product lines may require additional time for flushing and rinsing lines.

 

 

D.   Prepare cleaning solution as described in Section 2.2 above. Place end of syrup inlet line in

 

 

 

container filled with cleaning solution.

 

 

E.   Place waste container under applicable dispensing valve. Activate valve and draw cleaning

 

 

 

solution through lines for a minimum of 60 seconds. This will ensure line is flushed and filled

 

 

 

with cleaning solution. Allow line to stand for at least 30 minutes.

 

 

F.   Place end of syrup inlet line in a clean container filled with clean, potable, water at a

 

 

 

temperature of 90 to 110°F.

 

 

G.   Place waste container under applicable dispensing valve. Activate valve to flush and rinse line

 

 

 

and fittings for a minimum of 60 seconds to remove all traces of cleaning solution. Continue

 

 

 

rinsing until testing with phenolpthalein shows that the rinse water is free of residual detergent.

 

 

H.   Prepare sanitizing solution as described in Section 2.2 above. Place end of syrup inlet line in

 

 

 

container filled with sanitizing solution which has been prepared.

 

 

I.   Activate valve and draw sanitizing solution through line for a minimum of 60 seconds. This will

 

 

 

ensure line is flushed and filled with sanitizing solution. Allow line to stand for at least

    30 

minutes.

 

 

J.   Remove bag valve from quick disconnect coupling and reconnect syrup inlet line to syrup

 

 

 

package. Ready unit for operation.

16

Содержание 2300 Series

Страница 1: ...tserv lancercorp com lancercorp com Manual PN 28 0058 03 May 1998 FOR QUALIFIED INSTALLER ONLY Ice Cooled Dispener Series 2300 2400 Operation Manual PN 28 0058 03 Lancer is the registered trademark of...

Страница 2: ...COUNTER LOCATION 10 1 3 WATER SUPPLY 10 1 4 ELECTRICAL SUPPLY 11 1 5 SYRUP CONTAINERS 11 1 6 INSTALLATION OF THE UNIT 11 1 7 CONNECTION OF THE UNIT 12 1 8 START UP 12 13 1 9 ADJUSTING WATER FLOW 13 1...

Страница 3: ...inches 591 mm Depth 23 25 inches 591 mm ELECTRICAL 115 VAC 60 Hz WEIGHT Operating 206 lbs 93 kg Shipping 260 lbs 118 kg ICE Capacity 100 lbs 45 kg FITTINGS Soda water inlet 3 8 barb Brand syrup inlet...

Страница 4: ...1377 mm COUNTER CUT OUT Width 23 25 inches 591 mm Depth 24 inches 603 mm ELECTRICAL 24 VAC 60 Hz WEIGHT Operating 290 lbs 132 kg Shipping 196 lbs 89 kg ICE Capacity 100 lbs 45 kg FITTINGS Soda water i...

Страница 5: ...Rack BIB Regulator Set BIB Syrup Boxes BIB Connectors ensure you have the correct connectors for syrup lineup 5 TOOLS REQUIRED Oetiker Pliers Slotted Screwdriver Tubing Cutters Phillips Screwdriver Wr...

Страница 6: ...los ni os sin supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere l...

Страница 7: ...de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la corriente...

Страница 8: ...ques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres app...

Страница 9: ...local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo menos...

Страница 10: ...UPPLY CONTAINS ANY APPRECIABLE AMOUNT OF SILT SAND OR ANY OTHER DEBRIS FAILURE TO DO SO CAN RESULT IN EQUIPMENT DAMAGE PRECAUCI N UN FILTRO EN LA TUBER A DE AGUA DEBE SER USADO SI EL SUMINISTRO DE AGU...

Страница 11: ...RS NE BRANCHEZ PAS PLUSIEURS APPAREILS LECTRIQUES LA M ME PRISE DE COURANT 1 4 ELECTRICAL SUPPLY A A standard 15 AMP 110 VAC 60 Hz single phase electrical power outlet with a ground connector should b...

Страница 12: ...OMMAGES MAT RIELS E Mount the water filter assembly if required and water regulator if required in a convenient location CAUTION FAILURE TO LIMIT WATER PRESSURE TO 50 PSI 0 345 MPA WILL RESULT IN IMPR...

Страница 13: ...e ID panel UP until the flow controls are exposed see Figure 2 D Remove the nozzle by turning the nozzle counter clockwise and pulling down E Remove the diffuser by pulling the diffuser in a downward...

Страница 14: ...eded Keep exterior surfaces to include drip tray and cup rest of dispenser cleaned with damp clean cloth 2 2 CLEANING AND SANITIZING SYSTEMS A General Information 1 Lancer equipment new or recondition...

Страница 15: ...valves of the disconnect Rinse with clean potable water D Using a mechanical spray bottle and a sanitizing solution prepared in accordance with the instructions in Section 2 2 spray both halves of th...

Страница 16: ...alves valve spouts and cup levers Allow to air dry Y Fill ice bin with ice Install ice bin cover on unit NOTE Thoroughly rinse inside and outside of syrup tank that was used for sanitizing solution wi...

Страница 17: ...procedure Remove nozzle and diffuser Wash these parts in cleaning solution then immerse them in a bath of sanitizing solution for 15 minutes 2 Visually inspect around nozzle area for syrup residue Thi...

Страница 18: ...bonator pump for efficiency 3 2 Noisy Carbonator Pump A Insufficient water supply or water leak allowing air to be pulled into pump B Loose pump coupling A Provide adequate water supply Check strainer...

Страница 19: ...DIAGRAMS 5 1 LANCER ICE COOLED DISPENSER ACCESSORIES Illuminated Merchandiser PN 85 2304 T S Valve for Chilled Water PN 19 0036 Illuminated Marquee PN 85 2302 Water Spigot for Ambient Temperature Wate...

Страница 20: ...SERIES 2300 DROP IN COVER MUST BE COMPL ET EL Y CLO SE D TO OPE RATE VALV ES SL ID IN G COVER DO NOT LIFT 35 34 33 32 31 30 23 22 21 20 19 18 17 16 15 14 13 12 8 6 11 10 9 5 4 3 1 2 29 28 27 24 25 26...

Страница 21: ...52 0827 03 Wire Harness Assy 6 Valve 14 48 0776 Foamed Manifold 5 Valve 4 1 48 0767 Foamed Manifold 6 Valve 5 1 48 0851 Foamed Manifold 5 Valve 2 1 2 48 0850 Foamed Manifold 6 Valve 3 1 2 15 07 0360 P...

Страница 22: ...00 FREE STANDING CL OS ED TO OP ER AT E VA LV ES CO VE R MUS T BE CO MPL ET EL Y SL ID IN G CO VER DO NOT LIFT 32 33 30 22 21 20 19 18 17 31 34 35 36 16 15 14 8 11 12 13 7 6 5 4 3 1 2 9 10 29 28 27 26...

Страница 23: ...amed Manifold 5 Valve 4 1 48 0767 Foamed Manifold 6 Valve 5 1 48 0851 Foamed Manifold 5 Valve 2 1 2 48 0850 Foamed Manifold 6 Valve 3 1 2 14 07 0360 Plug 15 30 5986 Tower Cap 16 04 0148 Screw 10 32 X...

Страница 24: ...P IN WITH PLUG IN TOWERS CL OS ED TO OP ER AT E VA LV ES CO VE R MUS T BE CO MPL ET EL Y DO NO T LIFT SL ID IN G CO VE R 30 22 21 20 19 18 17 31 33 34 35 16 13 14 32 29 15 12 11 10 9 8 7 2 1 3 4 5 6 2...

Страница 25: ...re 15 06 0234 Coca Cola Sabre Sign 16 05 0332 Mounting Graphic Panel 17 48 1134 Foamed Manifold 5 Valve Sabre Plug In 48 0744 Foamed Manifold 6 Valve Sabre Plug In 48 1133 Foamed Manifold 5 Valve Stai...

Страница 26: ...5 5 SERIES 2400 FREE STANDING WITH PLUG IN TOWERS 32 33 30 22 21 20 19 18 17 31 34 35 36 16 29 15 13 14 12 11 10 9 8 7 4 5 6 27 28 26 25 24 23 3 1 2 26...

Страница 27: ...Cola Sabre Sign 16 05 0332 Mounting Graphic Panel 17 48 1134 Foamed Manifold 5 Valve Sabre Plug In 48 0744 Foamed Manifold 6 Valve Sabre Plug In 48 1133 Foamed Manifold 5 Valve Stainless Steel Plug I...

Страница 28: ...5 6 SERIES 2300 DROP IN PRE MIX 28 27 23 20 26 18 17 25 16 11 15 10 7 6 5 3 2 1 24 22 14 12 13 19 21 8 9 4 28...

Страница 29: ...30 5730 Faucet Plate 6 Valve 11 51 5161 01 Tower Body Stainless Steel 12 07 0360 Plug 13 30 5986 Tower Cap 14 04 0148 Screw 10 32 X 0 250 15 07 0555 Plug 16 C 15 0794 100 Yoke Fitting 17 01 0222 Fitt...

Страница 30: ...5 7 SERIES 2400 FREE STANDING PRE MIX 28 27 23 20 26 18 17 16 11 15 10 7 6 5 3 2 1 25 22 14 12 13 19 21 8 9 4 29 24 30...

Страница 31: ...0 Faucet Plate 6 Valve 11 51 5161 01 Tower Body Stainless Steel 12 07 0360 Plug 13 30 5986 Tower Cap 14 04 0148 Screw 10 32 X 0 250 15 07 0555 Plug 16 C 15 0794 100 Yoke Fitting 17 01 0222 Fitting 18...

Страница 32: ...S NOT USED IN CONJUNCTION WITH ALTERNATE POWER SUPPLY 2F 2F 2M 2F 2M F M WHITE M WHITE F Y WHITE F M WHITE F BLACK BLACK F 2M 2F WHITE WHITE F F WATER SPIGOT BUTTON 2F REPLACES INTERNAL CHERRY SWITCH...

Страница 33: ...PLY 2M BLACK WHITE 2M 2F 2F MARQUEE OR MERCHANDISER ALTERNATE POWER SUPPLY 2F 2M F F F F F Y WATER SPIGOT SOLENOID WATER SPIGOT BUTTON WHITE BLACK F Y BLACK WHITE BLACK VALVE MANIFOLD HARNESS 2M 3M 3F...

Страница 34: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: