Lancaster 7-LXDAN-1 Скачать руководство пользователя страница 4

PAGE 4

OPERATION:

1. Normal Operation Position:

 The inlet and outlet 

handles point in the direction of flow indicated by the 

engraved  arrows  on  the  control  valve.  Water  flows 

through the control valve during normal operation and 

this position also allows the control valve to isolate the 

media bed during the regeneration cycle. 

(see figure 

1)
2.  Bypass  Position: 

The  inlet  and  outlet  handles 

point  to  the  center  of  the  bypass,  the  control  valve 

is isolated from the water pressure contained in the 

plumbing system. Untreated water is supplied to the 

plumbing system. 

(see figure 2)

3.  Diagnostic  Position:

  The  inlet  handle  points  in 

the  direction  of  flow  and  the  outlet  handle  points  to 

the center of bypass valve, system water pressure is 

allowed to the control valve and the plumbing system 

while not allowing water to exit from the control valve 

to the plumbing. 

(see figure 3)

4. Shut Off Position: 

The inlet handle points to the 

center  of  the  bypass  valve  and  the  outlet  handle 

points  in  the  direction  of  flow,  the  water  is  shut  off 

to  the  plumbing  system.  If  water  is  available  on  the 

outlet  side  of  the  filter  it  is  an  indication  of  water 

bypass around the system (i.e. a plumbing connection 

somewhere  in  the  building  bypasses  the  system). 

(see figure 4)

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control 

valve repairs or maintenance. The X-Factor bypass valve is particularly unique in the water treatment industry due to its versatility 

and state of the art design features. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that 

allows service personal to work on a pressurized system while still providing untreated bypassed water to the facility or residence. Its 

completely non-metallic, all-plastic design allows for easy access and serviceability without the need for tools. 
The bypass body and rotors are glass filled Noryl

®

 (or equivalent) and the nuts and caps are glass filled polypropylene. All seals are 

self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal o-rings can easily be replaced if service is 

required.
The bypass consists of two interchangeable plug valves that are operated independently by red arrow-shaped handles. The handles 
identify the flow direction of the water. The plug valves enable the bypass valve to operate in four positions.

The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps. Before working on the 

rotors, make sure the system is depressurized. Turn the red arrow shaped handles towards the center of the bypass valve and back 

several times to ensure rotor is turning freely. 
The nuts and caps are designed to be unscrewed or tightened by hand. If necessary a pliers or the service spanner wrench can be 

used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps 

and/or tap with a hammer. 
Refer to page 15 for bypass valve parts diagram and page 16 for service spanner wrench information.
To access the rotor, unscrew the cap and lift the cap, rotor and handle out as one unit. Twisting the unit as you pull it out will help to 

remove it more easily. There are three o-rings: one under the rotor cap, one on the rotor stem and the rotor seal. Replace worn  

o-rings. Clean rotor. Reinstall rotor.
When reinstalling the red arrow handles be sure that:

1.  The handle pointers are lined up with the control valve body arrows, and the rotor seal o-ring and retainer on both rotors face 

to the right when being viewed from the front of the control valve; or

2.  Arrows point toward each other in the bypass position.

Since the handles can be pulled off, they could be accidentally reinstalled 180° from their correct orientation. To install the red arrow 

handles correctly, keep the handles pointed in the same direction as the arrows engraved on the control valve body while tightening the 

bypass valve caps. 

figure 1

figure 2

figure 3

figure 4

BYPASS VALVE

Содержание 7-LXDAN-1

Страница 1: ...inspection purposes please file this booklet with your important documents ELECTRONIC WATER FILTER WITH THE X FACTOR CONTROL VALVE INSTALLATION OPERATING AND SERVICE MANUAL WATER FILTERS AND NEUTRALI...

Страница 2: ...Instructions for 7 LXCTAIR 7 LXIMAIR 7 Placing Filter into Service 8 General Operation 8 Set Time of Day 9 Adjust Days Between Backwash or Time of Backwash 9 10 Low Battery 10 Contact Screen Programm...

Страница 3: ...damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part...

Страница 4: ...lass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings ca...

Страница 5: ...4 When assembling the installation fitting package inlet and outlet connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cement...

Страница 6: ...HOT LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SYSTEM IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS 5 FEET ABOVE CONNECTION ON CONTROL VAL...

Страница 7: ...NE AFTER THE AERATION SYSTEM BACKWASHES A SPUTTERING OF AIR MAY BE NOTICED AT THE FIRST WATER FIXTURE TO BE USED AFTER THE SYSTEM BACKWASHES IF THIS IS OBJECTIONABLE A CHECK VALVE CAN BE INSTALLED DIR...

Страница 8: ...an air pocket to form for the filter to function properly Control will automatically advance to the FILTERING position Open the outlet valve of the filter or if using optional bypass place to NORMAL...

Страница 9: ...and simultaneously for 3 seconds to access Installer Display Settings STEP 2 Day Override Set the maximum number of days between backwashes REGEN If value set to OFF backwash initiation is based solel...

Страница 10: ...digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward to the next ch...

Страница 11: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 12: ...Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back Plate 1 4 V3011 Piston Downflow Assy 1 5 V3174 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3...

Страница 13: ...tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a...

Страница 14: ...dge Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 3 4 NPT connection unless using 5 8 polytubing Do not use Vaseline oils other hydrocarbon lubricants or spr...

Страница 15: ...g Vertical Adapter Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES...

Страница 16: ...tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...cally depending on local conditions Pressure drop is very low DRIVE ASSEMBLY refer to pages 11 12 for diagrams Remove the valve cover to access the drive assembly Disconnect the power source plug blac...

Страница 19: ...seals with an o ring To remove the drive cap assembly use the special plastic service spanner wrench see page 16 or insert a to flat blade screwdriver into one of the slots around the top 2 of the dr...

Страница 20: ...iers if necessary Attached to the injector cap is a screen Remove the screen and clean if fouled The plug and or injector can be pried out with a small screwdriver The plug can be wiped clean If the p...

Страница 21: ...lace meter f Defective PC Board f Replace PC Board 4 Control valve backwashes at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Страница 22: ...tion or disconnect power supply from PC Board for 5 seconds and then reconnect b PC Board not properly snapped into drive bracket b Properly snap PC Board into drive bracket and then Press NEXT and RE...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b...

Страница 24: ...PAGE 24 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 8 12...

Отзывы: