Problem

Possible Cause

Solution

8. Untreated water is being delivered

a. Bypass valve is open or faulty

a. Fully close bypass valve or replace

b. Media is exhausted due to high water 

usage

b. Check program settings or diagnostics 

for abnormal water usage

c. Meter not registering

c. Remove meter and check for rotation or 

foreign material

d. Water quality fluctuation

d. Test water and adjust program values 

accordingly

e. Damaged seal/stack assembly

e. Replace seal/stack assembly

f. Control valve body type and piston type 

mix matched

f. Verify proper control valve body type 

and piston type match

g. Fouled media bed

g. Replace media bed

9. Water running to drain

a. Power outage during backwash

a. Upon power being restored control 

will finish the remaining backwash 

time. Reset time of day

b. Damaged seal/ stack assembly

b. Replace seal/ stack assembly

c. Piston assembly failure

c. Replace piston assembly

d. Drive cap assembly not tightened in 

properly

d. Re-tighten the drive cap assembly

10. Error – 101 = Control unable to sense motor 

movement

a. Motor not inserted full to engage pinion, 

motor wires broken or disconnected

a. Disconnect power, make sure motor is 

fully engaged, check for broken wires, 

make sure two pin connector on motor 

is connected to the two pin connection 

on the PC Board labeled MOTOR. 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

b. PC Board not properly snapped into drive 

bracket

b. Properly snap PC Board into drive 

bracket and then Press 

NEXT

 and 

REGEN

 buttons for 3 seconds to 

resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

c. Missing reduction gears

c. Replace missing gears

11. Error – 102 = Control valve motor ran too 

short and was unable to find the next cycle 

position and stalled

a. Foreign material is lodged in control valve a. Open up control valve and pull out 

piston assembly and seal/ stack 

assembly for inspection. Press 

NEXT

 

and 

REGEN

 buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

b. Mechanical binding

b. Check piston and seal/ stack assembly, 

check reduction gears, check drive 

bracket and main drive gear interface. 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

c. Main drive gear too tight

c. Loosen main drive gear. Press 

NEXT

 

and 

REGEN

 buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

d. Improper voltage being delivered to PC 

Board

d. Verify that proper voltage is being 

supplied. Press 

NEXT

 and 

REGEN

 

buttons for 3 seconds to resynchronize 

software with piston position or 

disconnect power supply from 

PC Board for 5 seconds and then 

reconnect.

Содержание 7-LXDAN-1

Страница 1: ...inspection purposes please file this booklet with your important documents ELECTRONIC WATER FILTER WITH THE X FACTOR CONTROL VALVE INSTALLATION OPERATING AND SERVICE MANUAL WATER FILTERS AND NEUTRALI...

Страница 2: ...Instructions for 7 LXCTAIR 7 LXIMAIR 7 Placing Filter into Service 8 General Operation 8 Set Time of Day 9 Adjust Days Between Backwash or Time of Backwash 9 10 Low Battery 10 Contact Screen Programm...

Страница 3: ...damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part...

Страница 4: ...lass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings ca...

Страница 5: ...4 When assembling the installation fitting package inlet and outlet connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cement...

Страница 6: ...HOT LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SYSTEM IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS 5 FEET ABOVE CONNECTION ON CONTROL VAL...

Страница 7: ...NE AFTER THE AERATION SYSTEM BACKWASHES A SPUTTERING OF AIR MAY BE NOTICED AT THE FIRST WATER FIXTURE TO BE USED AFTER THE SYSTEM BACKWASHES IF THIS IS OBJECTIONABLE A CHECK VALVE CAN BE INSTALLED DIR...

Страница 8: ...an air pocket to form for the filter to function properly Control will automatically advance to the FILTERING position Open the outlet valve of the filter or if using optional bypass place to NORMAL...

Страница 9: ...and simultaneously for 3 seconds to access Installer Display Settings STEP 2 Day Override Set the maximum number of days between backwashes REGEN If value set to OFF backwash initiation is based solel...

Страница 10: ...digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward to the next ch...

Страница 11: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 12: ...Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back Plate 1 4 V3011 Piston Downflow Assy 1 5 V3174 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3...

Страница 13: ...tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a...

Страница 14: ...dge Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 3 4 NPT connection unless using 5 8 polytubing Do not use Vaseline oils other hydrocarbon lubricants or spr...

Страница 15: ...g Vertical Adapter Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES...

Страница 16: ...tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...cally depending on local conditions Pressure drop is very low DRIVE ASSEMBLY refer to pages 11 12 for diagrams Remove the valve cover to access the drive assembly Disconnect the power source plug blac...

Страница 19: ...seals with an o ring To remove the drive cap assembly use the special plastic service spanner wrench see page 16 or insert a to flat blade screwdriver into one of the slots around the top 2 of the dr...

Страница 20: ...iers if necessary Attached to the injector cap is a screen Remove the screen and clean if fouled The plug and or injector can be pried out with a small screwdriver The plug can be wiped clean If the p...

Страница 21: ...lace meter f Defective PC Board f Replace PC Board 4 Control valve backwashes at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Страница 22: ...tion or disconnect power supply from PC Board for 5 seconds and then reconnect b PC Board not properly snapped into drive bracket b Properly snap PC Board into drive bracket and then Press NEXT and RE...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b...

Страница 24: ...PAGE 24 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 8 12...

Отзывы: