OPERATION:

1. Normal Operation Position:

 The inlet and outlet 

handles point in the direction of flow indicated by the 

engraved  arrows  on  the  control  valve.  Water  flows 

through the control valve during normal operation and 

this position also allows the control valve to isolate the 

media bed during the regeneration cycle. 

(see figure 

1)
2.  Bypass  Position: 

The  inlet  and  outlet  handles 

point  to  the  center  of  the  bypass,  the  control  valve 

is isolated from the water pressure contained in the 

plumbing system. Untreated water is supplied to the 

plumbing system. 

(see figure 2)

3.  Diagnostic  Position:

  The  inlet  handle  points  in 

the  direction  of  flow  and  the  outlet  handle  points  to 

the center of bypass valve, system water pressure is 

allowed to the control valve and the plumbing system 

while not allowing water to exit from the control valve 

to the plumbing. 

(see figure 3)

4. Shut Off Position: 

The inlet handle points to the 

center  of  the  bypass  valve  and  the  outlet  handle 

points  in  the  direction  of  flow,  the  water  is  shut  off 

to  the  plumbing  system.  If  water  is  available  on  the 

outlet  side  of  the  filter  it  is  an  indication  of  water 

bypass around the system (i.e. a plumbing connection 

somewhere  in  the  building  bypasses  the  system). 

(see figure 4)

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control 

valve repairs or maintenance. The X-Factor bypass valve is particularly unique in the water treatment industry due to its versatility 

and state of the art design features. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that 

allows service personal to work on a pressurized system while still providing untreated bypassed water to the facility or residence. Its 

completely non-metallic, all-plastic design allows for easy access and serviceability without the need for tools. 
The bypass body and rotors are glass filled Noryl

®

 (or equivalent) and the nuts and caps are glass filled polypropylene. All seals are 

self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal o-rings can easily be replaced if service is 

required.
The bypass consists of two interchangeable plug valves that are operated independently by red arrow-shaped handles. The handles 
identify the flow direction of the water. The plug valves enable the bypass valve to operate in four positions.

The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps. Before working on the 

rotors, make sure the system is depressurized. Turn the red arrow shaped handles towards the center of the bypass valve and back 

several times to ensure rotor is turning freely. 
The nuts and caps are designed to be unscrewed or tightened by hand. If necessary a pliers or the service spanner wrench can be 

used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps 

and/or tap with a hammer. 
Refer to page 15 for bypass valve parts diagram and page 16 for service spanner wrench information.
To access the rotor, unscrew the cap and lift the cap, rotor and handle out as one unit. Twisting the unit as you pull it out will help to 

remove it more easily. There are three o-rings: one under the rotor cap, one on the rotor stem and the rotor seal. Replace worn  

o-rings. Clean rotor. Reinstall rotor.
When reinstalling the red arrow handles be sure that:

1.  The handle pointers are lined up with the control valve body arrows, and the rotor seal o-ring and retainer on both rotors face 

to the right when being viewed from the front of the control valve; or

2.  Arrows point toward each other in the bypass position.

Since the handles can be pulled off, they could be accidentally reinstalled 180° from their correct orientation. To install the red arrow 

handles correctly, keep the handles pointed in the same direction as the arrows engraved on the control valve body while tightening the 

bypass valve caps. 

figure 1

figure 2

figure 3

figure 4

BYPASS VALVE

Содержание 7-LXCT-1

Страница 1: ...e inspection purposes please file this booklet with your important documents ELECTRONIC WATER FILTER WITH THE X FACTOR CONTROL VALVE INSTALLATION OPERATING AND SERVICE MANUAL WATER FILTERS AND NEUTRALIZERS ACID NEUTRALIZERS 7 LXDAN 1 7 LXDAN 1 5 7 LXDAN 2 7 LXDAN 3 IRON FILTER 7 LXIM 1 7 LXIM 2 7 LXIM 3 COLOR TASTE ODOR 7 LXCT 1 7 LXCT 2 7 LXCT 3 SEDIMENT TURBIDITY 7 LXST 1 7 LXST 2 7 LXST 3 AERAT...

Страница 2: ...n Instructions for 7 LXCTAIR 7 LXIMAIR 7 Placing Filter into Service 8 General Operation 8 Set Time of Day 9 Adjust Days Between Backwash or Time of Backwash 9 10 Low Battery 10 Contact Screen Programming 10 Parts Diagrams 11 17 Service Instructions 18 20 Troubleshooting 21 23 COMPONENTS MODEL MINERAL TANK PART NO dia x ht PART ID MINERAL BAG qty 7 LXCT 2 FG1348VT 13x48 A8009 CARBON 2 7 LXCT 3 FG1...

Страница 3: ...y damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part of the o ring split rings bypass valve or control valve Install grounding strap on metal pipes This water filter is not to be used for treating water that is microbiologically unsafe or of unknown qu...

Страница 4: ...glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings can easily be replaced if service is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow direction ...

Страница 5: ... 4 When assembling the installation fitting package inlet and outlet connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cements may damage the nut split ring or o ring Solder joint should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any ...

Страница 6: ... HOT LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SYSTEM IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS 5 FEET ABOVE CONNECTION ON CONTROL VALVE OR IF DRAIN LINE EXCEEDS 20 FEET IN LENGTH DRAIN LINE PIPE SIZE SHOULD BE MINIMUM 3 4 LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SY...

Страница 7: ...INE AFTER THE AERATION SYSTEM BACKWASHES A SPUTTERING OF AIR MAY BE NOTICED AT THE FIRST WATER FIXTURE TO BE USED AFTER THE SYSTEM BACKWASHES IF THIS IS OBJECTIONABLE A CHECK VALVE CAN BE INSTALLED DIRECTLY AFTER THE AERATION SYSTEM NOTE IF A CHECK VALVE IS INSTALLED BETWEEN A PRESSURE TANK AND A WATER HEATER A HOT WATER EXPANSION TANK IS REQUIRED ON THE COLD WATER INLET OF THE WATER HEATER A SMAL...

Страница 8: ...s an air pocket to form for the filter to function properly Control will automatically advance to the FILTERING position Open the outlet valve of the filter or if using optional bypass place to NORMAL OPERATION MODE see figure 1 on page 4 FOR ALL OTHER FILTERS When water is flowing steadily to drain without the presence of air momentarily press REGEN again Display will read RINSE Open the outlet v...

Страница 9: ... and simultaneously for 3 seconds to access Installer Display Settings STEP 2 Day Override Set the maximum number of days between backwashes REGEN If value set to OFF backwash initiation is based solely on volume used If value is set as a number allowable range from 1 to 28 a backwash initiation will be called for on that day even if sufficient volume of water were not used to call for a backwash ...

Страница 10: ... digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward to the next character or to exit the Installer Display Settings A non rechargeable coin cell battery is located on the circuit board used only to maintain the time of day during power outages all other information...

Страница 11: ...ush down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons unplug power source jack from the printed circuit board black wire and plug back in or press and hold NEXT and REGEN buttons for 3 se...

Страница 12: ... Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back Plate 1 4 V3011 Piston Downflow Assy 1 5 V3174 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O ring 215 Distributor Tube 1 Not Shown V3001 Body Assy Downflow 1 Only used with 7 LXCTAIR and 7 LXIMAIR models DRIVE CAP ASSEMBLY DOWNFLOW PISTON REGENERANT PISTON AND SPAC...

Страница 13: ...r tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a screwdriver in slots on caps and or tap with a hammer Refer to page 20 for detailed service instructions Drawing No Order No Description Qty 1 V3151 Nut 1 QC 1 2 V3003 Meter Assy 1 3 V3118 01 Turbine...

Страница 14: ...edge Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 3 4 NPT connection unless using 5 8 polytubing Do not use Vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicone lubricant may be used on black o rings but is not necessary Dwg No Order No Description Qty 1 H4615 Elbow Locking Clip 1 2 V3008 02 Drain FTG 1 Straight 1 3 V3166 Drai...

Страница 15: ...ng Vertical Adapter Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 1 NPT connection Teflon tape is not necessary on the nut connection nor caps because of o ring seals The nut a...

Страница 16: ...o tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens Drive Cap SERVICE SPANNER WRENCH ...

Страница 17: ...uantity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fitting 1 1 Brass Sweat 2 Order No V3007 07 Description Fitting 1 1 PVC Solvent Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 ...

Страница 18: ...ically depending on local conditions Pressure drop is very low DRIVE ASSEMBLY refer to pages 11 12 for diagrams Remove the valve cover to access the drive assembly Disconnect the power source plug black wire from the PC board prior to disconnecting the motor or water meter plugs from the PC board The power source plug connects to the four pin jack The motor plug connects to the two pin jack on the...

Страница 19: ...d seals with an o ring To remove the drive cap assembly use the special plastic service spanner wrench see page 16 or insert a to flat blade screwdriver into one of the slots around the top 2 of the drive cap assembly so it engages the notches molded into the drive back plate around the top 2 of the piston cavity See figure below The notches are visible through the holes Lever the screwdriver so t...

Страница 20: ...liers if necessary Attached to the injector cap is a screen Remove the screen and clean if fouled The plug and or injector can be pried out with a small screwdriver The plug can be wiped clean If the plug leaks replace the entire plug The injector consists of a throat and a nozzle Chemically clean the injector with vinegar or sodium bisulfite The holes can be blown out with air Both pieces have sm...

Страница 21: ...place meter f Defective PC Board f Replace PC Board 4 Control valve backwashes at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See Front Cover and Drive Assembly drawing for instructions b Time of day not set correctly b Reset to correct time of day c Time of backwash set incorrectly c Reset backwash time d Control valve s...

Страница 22: ...ition or disconnect power supply from PC Board for 5 seconds and then reconnect b PC Board not properly snapped into drive bracket b Properly snap PC Board into drive bracket and then Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Missing reduction gears c Replace missing gears 11...

Страница 23: ...s NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b MAV NHBP motor wire not connected to PC Board b Connect MAV NHBP motor to PC Board two pin connection labeled MAV MTR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston...