PAGE 11
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING
DEVICE FOR CRITICAL OR HEALTH EFFECT APPLICATIONS.
The nut and caps are designed to be unscrewed or tightened by hand or with the
service spanner wrench (see page 16). If necessary a pliers can be used to unscrew
the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not
place a screwdriver in slots on caps and/or tap with a hammer.
Refer to page 17 for detailed service instructions.
Drawing No. Order No.
Description
Qty
1
V3151
Nut 1” QC
1
2
V3003*
Meter Assy
1
3
V3118-01 Turbine Assy
1
4
V3105
0-ring 215
1
*Order number V3003 includes V3118-01 Turbine
Assy and V3105 O-ring 215.
REFILL FLOW CONTROL ASSEMBLY
WATER METER
Refer to page 16 for detailed service instructions.
Drawing No. Order No.
Description
Qty
1
H4615
Elbow Locking Clip
1
2
H4628
Elbow 3/8” Liquifit
1
3
V3163
O-ring 019
1
4
V3165-01*
RFC Retainer Assy (0.5 gpm)
1
5
V3182
RFC
1
6
V4144-01
Elbow 3/8 Liquifit Assy w/RFC
1
*Assembly includes V3182 RFC.
Drawing No.
Order No.
Description
Quantity
1
V3195-01
WS1 Refi ll Port Plug Asy
This part is required for backwash only systems
2
H4615
Elbow Locking Clip
1
3
H4628
Elbow 3/8” Liquifi t
1
4
V3163
0-ring 019
1
5
V3165-01*
WS1 RFC Retainer Asy (0.5 gpm)
1
6
V3182
WS1 RFC
1
7
V4144-01
Elbow 3/8 Liquifi t Asy w/RFC
1
Not Shown
V3552
WS1 Brine Elbow Asy w/RFC
Option
Not Shown
H4650
Elbow ½” with nut and insert
Option
*Assembly includes V3182 WS1 (0.5 gpm) RFC.