Страница 1: ...el values of warning and overload set each circuit delay time to prevent the impact of power surge to the power supply system LED indicates power supply condition of each switch LED digital display shows the current value of voltage and current provides local query buttons of PDU equipment built in lightning protection circuit and resisting voltage surge circuit can protect the server effectively ...

Страница 2: ...1 7 https www armadi rack it code id_prod 103222 ...

Страница 3: ...Key Check the machine IP address 5 Meter Panel Display voltage current temperature humidity etc 6 Temperature and humidity sensor 7 Network Port Connect LAN or WAN Using Directions 1 Equipment connection Connect LIU 0816 8 IEC C13 output plug with one side of the output line 2 7 https www armadi rack it code id_prod 103222 ...

Страница 4: ...ng the FUNC button in the state of screen shows the IP address The left screen shows temperature and the right screen shows humidity 4 Reset of the equipment Press the LIU 0816 WN RST button on the front panel it will reset 5 Restore the factory default value of the device Press the FUNC key 10 15S to hear the buzzer drop two to indicate the IP address of the device The user name and password are ...

Страница 5: ...3 7 https www armadi rack it code id_prod 103222 ...

Страница 6: ... the drop down box behind the action box choose Start And then click the small box behind outlet1 outlet2 outlet3 outlet4 respectively click Apply button The second method click the drop down box behind the action box choose Shut off And then click the small box behind outlet5 outlet6 outlet7 outlet8 respectively click Apply button Power off memory function After the port is opened or closed on th...

Страница 7: ...4 7 https www armadi rack it code id_prod 103222 ...

Страница 8: ...ace as shown below The picture above is the factory Settings the meaning is Current warning value 17A When the total current exceeds 17A LIU 0816 WN buzzer sends out beep beep sound alarm Current overload value 17A When the total current exceeds 17 a LIU 0816 WN will cut off the power supply of all output port Warning voltage 250V When the input voltage exceeds 250V LIU 0816 WN buzzer sends out be...

Страница 9: ... confirmation respectively click apply button the new user name and password will be used at the next time login LIU 0816 WN Note User name change can support up to 15 digits in English and the number can t be entered later The password can support up to 11 digits in English and the number can t be entered later IP address and DNS Setting Click network in the configuration box which is on the left...

Страница 10: ...6 7 https www armadi rack it code id_prod 103222 ...

Страница 11: ...gateway of LIU 0816 WN Enable the DHCP The superior router of the current LAN will distribute network parameters automatically for LIU 0816 WN it will come into force after clicking the apply button Primary DNS IP refer to the supervisor router setting of current LAN Secondary DNS IP refer to the supervisor router setting of current LAN 7 7 https www armadi rack it code id_prod 103222 ...