background image

 

 

11

 / 

11

 

 

1.

 

The connecting wire must be plugged into the port from which it is pulled out. 

2.

 

Plug the mouse before the keyboard. 

Note: The KVM control platform must be power on before PC. 
 

Power On/Off and Reboot 

If user needs to cut off the power of KVM control platform, please follow the steps before power on 
again. 
1.

 

Cut off the power supply of all computers. 

Note:  
1) The power wire of computer with keyboard power on function must be pulled out. Otherwise, the 
KVM still receives the power signal from computer. 
2) If the control unit uses the external power, please pull out external power. 
2. After about 10 seconds, power on the KVM control platform. 
3. After the KVM switch starts, power on the computers. 

INTERFACE SELECTION 

There are two ways to select: Hot key and OSD menu. 

HOTKEY 

The hotkey let the user control the connected computers by keyboard. Please check AUTO 
SWITCH user manual. 

 

FCC NOTE: 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions:(1)this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation. 
 
This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:  
-- Reorient or relocate the receiving antenna 
-- Increase the separation between the equipment and receiver.   
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.  
-- Consult the dealer or an experienced radio/TV technician for help. 
 
The manufacturer is not responsible for any radio or TV interference caused by unauthorized 
modifications to this equipment. Such modifications could void the user's authority to operate the 
equipment. 

Содержание AS-3100L Series

Страница 1: ... 8 16ports AS 9100L Series Products KVM Control Platform 1 19 inches LCD screen keyboard and mouse control platform integrated KVM switch with multiple ports 4 8 16ports Cable KVM Connecting Cable 1 4 8 16 PS 2 Connecting and USB Connecting AC Power Power Cable 1 AC power connecting cable KVM Control User Manual User Manual 1 2 LCD Manual and KVM Manual Please check the lists carefully and contact...

Страница 2: ...2 11 ...

Страница 3: ...it can control 256 PC at most by 3 level cascade connection It is easy and quick to install Just connect the wire to the correct port without software configuration So there is no difficulty in installation and incompatibility KVM switch provides two methods to control the computers connected to it 1 By keyboard combine key 2 By OSD operation In addition it provides powerful automatic scanning fun...

Страница 4: ...nd 4 8 16 ports USB KVM And Body parts can be easily demolished AS 9100L No 19 inches LCD screen keyboard and mouse And Body parts can be easily demolished AS 9104 08 16RDL Yes 19 inches LCD screen keyboard mouse and 4 8 16 ports PS 2 KVM And Body parts can be easily demolished AS 9104 8 16UDL Yes 19 inches LCD screen keyboard mouse and 4 8 16 ports USB KVM And Body parts can be easily demolished ...

Страница 5: ...A video input Accord with DDC DDC2 DDC2B standard and VESA standard Support maximum resolution of 1920 1440 Support multiple operating systems WIN95 98 98SE ME 200 XP WIN NT UNIX LINUX FRONT VIEW 1 Front panel 2 Handle 3 LCD screen 4 Keyboard 5 Mouse touch board 6 Rear hang ear channel 7 Guide 8 Front hang ear 9 LCD OSD control key 1 2 3 4 5 6 7 8 9 REAR VIEW AS 3104UDL AS 7104UDL AS 9104UDL AS 31...

Страница 6: ...0mA power socket PC connecting port KVM CONTROL PLATFORM CONNECTING WIRE Cable Type Applicable Type KVM Port PC or Server Port USB Connecting Cable AS 3104 08 16UDL Series Products VGA port Keyboard mouse and monitor VGA Keyboard Mouse Standard USB Interface PS 2 Connecting Cable AS 3104 08 16RDL Series Products VGA Port Keyboard mouse And monitor VGA Keyboard Mouse Standard PS 2 Interface ...

Страница 7: ...onnecting 1 8m Cable PS 2 Connecting 1 8m Cable USB and PS 2 Connecting 1 8m Cable KVM CONTROL PLATFORM POWER WIRE Wire Type Note Voltage Range Machine Type AC Power Wire 3 Plugs of National Standard 100 230V All ...

Страница 8: ...8 11 AC Power Wire DIMENSION CONNECTION OF KVM SIGNAL WIRE 1 PS 2 connecting wire Connect the end with 3 sockets to the KVM control platform and the other to the computer 2 USB connecting wire ...

Страница 9: ...mputer OPERATIO Before Use z Make sure all the devices safely grounded z Make sure the KVM wire and power wire connected correctly During Use z Pull the KVM control platform out from cabinet totally the guide locks automatically and the power turns on z Release front lock As shown below ...

Страница 10: ...ress LCD power key the LCD is power off z Close LCD panel and lock the front panel z Release guide lock z Push the control panel into the cabinet totally and then it is power off Hot Plug The KVM control platform supports hot plug It can be connected and disconnected without power off Please follow the steps Hot plug PC connecting port When hot plugging PC port ...

Страница 11: ...ing interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Отзывы: