background image

 Equipment Issue A

030‐101643 Rev. B, May 2012

Section BXM‐05V‐20A

R

Copyright

E

 2012 Westell, Inc. All rights reserved.  

Westell

r

 is a registered trademark of and Boxer

t

 is a trademark of Westell, Inc.

Page 1 of 12

1205IARB

Boxer

t

 BXM05V19‐NMT

Sealed Outdoor Cabinet with Vertical 5‐RU‐Rack

CONTENTS

PAGE #

1. GENERAL

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. FEATURES 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. INSTALLATION

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. SERVICE & REPAIRS

9

. . . . . . . . . . . . . . . . . . . . . . . . .

5. CUSTOMER & TECHNICAL SERVICES 

9

. . . . . . . .

6. WARRANTY & RETURNS

9

. . . . . . . . . . . . . . . . . . . . . .

7. SPECIFICATIONS

10

. . . . . . . . . . . . . . . . . . . . . . . . . . .

1.

GENERAL

1.1

Document Purpose

This document provides general, installation, and specifica­
tion information for the Westell

r

 Boxer

t

 BXM05V19‐NMT

Outdoor Cabinet with a built‐in, vertically‐oriented, 5‐RU by
19” relay rack. This product is designed to provide Network
equipment protection in outdoor environments. The intended
audience for this document is engineering, operations, and
installation personnel of MSO, Telco, and utility companies.
See Figure 1 for a closed view of the product, and  Table 3 for
product ordering information and available options to use with
the BXM05V19‐NMT.

‐ NOTE ‐

Hereafter, the BXM05V19‐NMT Boxer cabinet also may be
commonly referred to as the “Boxer 5” or cabinet.”

1.2

Document Status

Whenever this practice is updated, the reason will be stated in
this paragraph. Revision B updates the Boxer part number and
updates Paragraph 1.3.

1.3

Product Purpose and Description

Boxer is a compact, NEMA 4, weather‐tight, outdoor cabinet
that houses and protects a wide range of electronic equipment.
Up to 5 RUs (8.75”) of rack space (19” racks) is available to
mount Network equipment inside the cabinet, such as:

S

Ethernet switches

S

Multiplexers

S

Fiber terminating equipment

S

Copper bonding solutions

S

Radio equipment

S

Smart Grid equipment

S

Media converters

S

xDSL boxes

Figure 1.

Isometric Closed View of Boxer Cabinet

Figure 2.

Open View of Boxer Cabinet

Weather Stripping

19” Rack

Channel

(see also

Figure 8

Figure 14

)

Cable

Access

Knock‐outs

Mesh Interior

Back Plate

Door Switch

S

DS3 hand‐offs, and

S

Virtually any equipment than can be mounted on the in­
ternal mesh backboard or in a 19” rack

Adjustable rack channels are mounted inside the cabinet at the
top and bottom walls, for a 

rotated‐rack

 effect, allowing equip­

ment to be mounted vertically in the cabinet and minimizing or
streamlining the cabinet width. Boxer supports rapid equip­

Содержание Boxer BXM05V19-NMT

Страница 1: ... NMT Boxer cabinet also may be commonly referred to as the Boxer 5 or cabinet 1 2 Document Status Whenever this practice is updated the reason will be stated in this paragraph Revision B updates the Boxer part number and updates Paragraph 1 3 1 3 Product Purpose and Description Boxer is a compact NEMA 4 weather tight outdoor cabinet that houses and protects a wide range of electronic equipment Up ...

Страница 2: ...ottom accept a variety of cable conduit and connector sizes and types six 1 two 2 S Door security via a locking hex cup washer bolt which also accepts a padlock S Door sensor alarm switch for optional alarm security S Included mounting brackets allow pole H frame wall or square post mounting S Optional battery backup box available knock out hole patterns match in both units S Bagged parts self tap...

Страница 3: ... has three mounting holes or slots The center hole of the top bracket is a keyhole for easy one person cabin et self leveling mounting Use mounting fasteners with a diameter of up to 3 8 The vertical distance between the top and bottom mounting bracket hole centers is 25 18 see Figure 5 Quantity Description 2 2 5 knock out for 2 conduit 6 1 125 knock out for 3 4 conduit Table 1 Knock out Sizes and...

Страница 4: ... A ground plate is provided that contains five sets of ground posts and one copper ground lug for cable and chassis earth ground Bond equipment cables to the ground posts per company prac tice and connect a 6 AWG chassis or earth ground wire to the ground lug An Electro Static Discharge ESD wrist strap jack is also located on the ground plate 3 INSTALLATION Use and follow local codes and company p...

Страница 5: ...stance from the cable entry point or from upstream or downstream equipment 3 4 Gathering all Tools and Equipment The following tools and supplies not provided are required to mount the Boxer cabinet Door Opening Locking Tools V 7 16 can wrench or 216 tool V Padlock optional Knock Out Removal Tools V Hammer V Punch V Pliers Cabinet Mounting Tools Equipment and Hardware V Tape measure V Marking uten...

Страница 6: ...nt of the mount ing to allow the door to open see Figure 4 and at the sides in the event of any multiple installations 2 Remove knock outs See the steps in Paragraph 3 5 Re moving the Knock outs to remove the knock outs where any cable access holes or holes for mounting the optional battery box are desired 3 Prepare the mounting hardware Bring the appropriate mounting hardware to the installation ...

Страница 7: ...Drill appropriately sized pilot holes slightly smaller than the width and depth of the bolts at the marked loca tions Do not drill the holes too large 10 Install bottom mounting bolts Insert and drive all bottom bolts completely in to their final seated position Finish the installation by verifying all bolts are firm and snug 11 Determine next step or close up cabinet and clean the site Repeat Ste...

Страница 8: ...of the cabinet 4 Verify each piece of equipment does not exceed the cabi net s interior width or depth 5 Determine the best mounting location for each piece of equipment for maximum capacity 6 Determine adjust the rack channel depth optional If the factory installed rack channels are not at the proper equip ment projection depth adjust the channels at this time Remove the nuts that secure each cha...

Страница 9: ...assembly and return it to Westell for service then replace it To remove and replace the door alarm switch assembly proceed with the following instructions 1 Open the cabinet Open the large main cabinet door 2 Remove door sensor assembly mounting screws Remove the nuts that attach the door alarm sensor to the threaded posts in the top right inside corner of the open cabinet 3 Partially pull out doo...

Страница 10: ...cycle and dispose of the products per your company prac tice per local recycling programs and local codes and per state statutes 7 SPECIFICATIONS 7 1 Physical Specifications The Boxert physical specifications are shown in Table 2 7 2 Regulatory Agency Specifications The Boxer cabinet is designed to meet the following regulatory safety or environmental specifications or requirements S NEMA 4 compli...

Страница 11: ...Section BXM 05V 20A 030 101643 Rev B R 11 1205IARB Figure 15 Knock out Locations and Sizes 1 13 KNOCK OUT 6 PLCS ...

Страница 12: ...Section BXM 05V 20A 030 101643 Rev B R 12 1205IARB Figure 16 Front View Door Open 25 2 27 7 0 625 dia 7 Depth door closed 18 23 1 5 1 5 0 375 dia 0 375 dia ...

Отзывы: