![Lampert PUK S450 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/lampert/puk-s450/puk-s450_operating-manual_3438127006.webp)
© Lampert Werktechnik GmbH
2018
5
4.2 DESCRIPTION OF THE REAR OF THE DEVICE
(Fig. 2)
(1)
FUSEBOX ("Fuse")
(2)
MAINS SWITCH as well as
AC POWER SOCKET
(for connecting the mains cable)
(3)
CONNECTION SOCKET FOR EYE PROTECTION
SYSTEM AND LED ILLUMINATION
(4)
CONNECTION SOCKET FOR FOOT SWITCH AND
ABSORBER (optional accessory)
(5)
TYPE PLATE
(6)
SERIAL NUMBER
(7) PROTECTIVE GAS CONNECTION ("ARGON GAS")
for 6.0 mm diameter pressure hose (max. 4.0 bar)
(8)
APPROVED MAINS VOLTAGE FOR THIS DEVICE
4.3 CONNECT EYE PROTECTION AND LED ILLUMINATION TO THE „PUK S450“:
The circular connector for the eye protection system and
the LED illumination should be inserted into the
connecting socket (3) on the rear of the „PUK S450“
welding device and is to be tightened in place with the
coupling nut (hand tight).
WARNING!
ONLY SUITABLE ORIGINAL EYE PROTECTION
SYSTEMS FROM LAMPERT MAY BE CONNECTED TO
THE WELDING SYSTEM!
OTHER EYE PROTECTION SYSTEMS ARE NOT
APPROVED AND CAN LEAD TO PERMANENT HEALTH
DAMAGE OR DAMAGE TO THE WELDING DEVICE.
ALWAYS OBSERVE THE OPERATING INSTRUCTIONS FOR THE CONNECTED EYE PROTECTION SYSTEM
4.4 CONNECT SHIELDING GAS SUPPLY:
Fasten the suitable flow regulator with the corresponding
tool to the shielding gas tank. ATTENTION: In doing so,
always
observe
the
enclosed
special
operating
instructions provided. (Where possible, use argon with
min. 99.9% purity, e.g. "Argon 4.6"). The pressure hose is
to be fastened by hand with the help of the quick coupling
adapter to the flow regulator as well as the shielding gas
connector (7) on the rear of the device.
CHECK REGULARLY THAT ALL OF THE HOSE CONNECTIONS AND GAS HOSES ARE IN OPTIMAL
CONDITION, ARE PROPERLY FASTENED AND ARE AIRTIGHT!