11
8. CARE OF THE SYSTEM COMPONENTS
8.1
CARE OF WELDING DEVICE
Your „PUK S450“ requires a minimum of maintenance
under normal working conditions
. However, it is essential
that a few points are observed in order to guarantee the
functionality and to keep the spot welding device fully
operational for years to come.
•
Check the mains plug and cable as well as all welding
and connection cables regularly for damage.
•
Check that the moving parts of the handpiece move
easily.
•
If necessary, clean the electrode threaded assembly on
the handpiece, in order to ensure optimal contact with
the electrodes.
•
Clean the device occasionally with a suitable cloth.
IF WORK OR REPAIRS THAT ARE NOT DESCRIBED IN THESE OPERATING INSTRUCTIONS ARE
NECESSARY THEN CONTACT YOUR DEALER.
WARNING!
IF FUSES REQUIRE EXCHANGING, THEN THEY MUST BE REPLACED WITH FUSES OF THE SAME TYPES
AND VALUES.
THE GUARANTEE IS VOID IN THE EVENT OF EXCESSIVLY HIGH FUSING!
THE DEVICE MAY ONLY BE OPENED BY A QUALIFIED ELECTRICIAN!
9. TECHNICAL DATA
9.1
TECHNICAL DATA WELDING DEVICE
Device suitable for welding in dry rooms
Mains voltage
Mains fusing
Power consumption (during welding)
Closed-circuit voltage
No-load voltage
Duty cycle X
Max. charging time
Shielding gas
Maximum gas pressure
Protection class
Insulation class
Protection type
Weight
~230 V / 50-60 Hz +/-10%
T 3.15 A
400VA
30 – 43 V
43 V
80 %
0.8 s
min. ARGON 99.996%
4 bar
I
B
IP 21S
7.1 kg