background image

 

© Lampert Werktechnik GmbH 

2017 

  16 

 

8. CARE OF THE SYSTEM COMPONENTS 

 

8.1 CARE OF WELDING DEVICE AND WELDING MICROSCOPE  

Your  PUK  as  well  as  the  welding  microscope  require  a 
minimum 

of 

maintenance 

under 

normal 

working 

conditions

.  However,  it  is  essential  that  a  few  points  are 

observed  in  order  to  guarantee  the  functionality  and  to 
keep the spot welding device fully operational for years to 
come. 

  Check the mains plug and cable as well as all welding 

and connection cables regularly for damage. 

  Check that the moving parts of the handpiece move 

easily. 

  If necessary, clean the electrode threaded assembly on 

the handpiece, in order to ensure optimal contact with 
the electrodes. 

  Clean the device occasionally with a suitable cloth. 

  Use the supplied dust cover to cover up the microscope 

after use.  

 

 IF WORK OR REPAIRS THAT ARE NOT DESCRIBED IN THESE OPERATING INSTRUCTIONS ARE 
NECESSARY THEN CONTACT YOUR DEALER. 

 

WARNING! 

 

IF FUSES REQUIRE EXCHANGING, THEN THEY MUST BE REPLACED WITH FUSES OF THE SAME TYPES AND 
VALUES. THE GUARANTEE IS VOID IN THE EVENT OF EXCESSIVLY HIGH FUSING! 

 

THE DEVICE MAY ONLY BE OPENED BY A QUALIFIED ELECTRICIAN!

 

 

 

8.2 CARE OF THE OPTICAL COMPONENTS

Do  not  attempt  to  disassemble  optical  components. 
Please  contact  the  local  technical  customer  service 
department  for  repairs  which  are  not  covered  by  this 
manual.  

Remove  dust  from  the  lens  surface  with  a  special  brush 
prior  to  cleaning.  You  can  obtain  suitable  accessories  in 
any photography store. 

Cleaning the oculars: Do not remove the oculars (17) from 
the ocular tubes (15). 

Clean  the  outer  surfaces.  In  doing  so,  breathe  on  them. 
Subsequently dry the lens with suitable cloth or paper for 
the purpose. Dry the lens with circular movements from 

 

the centre to the outside. Do not wipe over a dried lens as 
they can easily be scratched.  

Cleaning  and  exchanging  the  protective  glass  of  the  eye 
protection filter: 

Never dismantle the eye protection filter (shutter)! 

Only  clean  the  surface.  Use  a  cotton  cloth  with  glass 
cleaner.  

If  the  protective  glass  requires  exchanging,  slide  it 
forwards  out  of  the  bracket  and  insert  a  new  protective 
glass in the same manner. 

 

 

 

 

 

 

 

 

Содержание PUK D3

Страница 1: ...Operating manual PUKD3...

Страница 2: ...O LIABILITY FOR DAMAGES CAUSED THROUGH INAPPROPRIATE USE AND IMPROPER OPERATION THE GENERAL SAFETY REQUIREMENTS AND PERSONAL BODY PROTECTION CHAPTERS MUST BE READ BEFORE COMMISSIONING Please keep thes...

Страница 3: ...RUCTIONS 7 1 Introduction to welding Pg 13 7 2 Welding with the smoothing mode Pg 14 7 3 Retention welding Pg 14 7 4 Welding with the foot switch Pg 14 7 4 1 Fixation welding Pg 14 7 4 2 Retention wel...

Страница 4: ...to be clearly blocked when undertaking any work on the system beyond minor manipulations where it is necessary to leave the workplace even for brief periods The highest and thus the most dangerous vo...

Страница 5: ...y glasses with suitable protective glass SMOKES AND GASES When welding especially in small spaces ensure that there is an adequate fresh air supply or use an external extractor fan as smoke and hazard...

Страница 6: ...ghtened in place with the coupling nut hand tight WARNING ONLY SUITABLE ORIGINAL EYE PROTECTION SYSTEMS FROM LAMPERT MAY BE CONNECTED TO THE WELDING SYSTEM OTHER EYE PROTECTION SYSTEMS ARE NOT APPROVE...

Страница 7: ...g 4 6 CONNECT POWER SUPPLY Insert the power cable with the mains connector into the corresponding socket 2 on the rear of the housing and insert the mains plug into a suitable socket with the correct...

Страница 8: ...20 to focus the image DIOPTRE ADJUSTMENT The sleeve for adjusting the dioptre 16 is fitted to the left hand ocular 17 In the normal position the lower part of the tube is aligned to the marking on the...

Страница 9: ...N BE NAVIGATED AFTER PRESSING LONGER 1 SEC THE ROTARY CONTROLLER 25 a Start level main menu Preselection of the material to be welded and preselection of the welding situation with display of the reco...

Страница 10: ...s correctly adjusted close again the Gas valve function by pressing the corresponding button 5 5 OPERATING LEVEL SETTINGS The Settings user level can be used to modify basic settings and launch variou...

Страница 11: ...CTS OF WELDING POWER AND WELDING TIME POWER With the parameter welding power the strength of welding energy is set The size and intensity of the welding points are controlled in this way i e the highe...

Страница 12: ...ange are always possible however they are not recommended for the selected welding situation RED RANGE If you move above the predefined values for welding time and welding power the colour of the curs...

Страница 13: ...he info screen to appear for the respective button which contains explanatory information for the button s function Touching the display button again causes the active user screen to be shown once mor...

Страница 14: ...with the contact clamp Lightly touch the area to be welded with the tip of the electrode until welding begins In doing so it is important to remain in the position where initial contact is made until...

Страница 15: ...ght touch triggers the welding process during the continuous tone A good welded connection is indicated by a clearly audible welding noise If the process passes off without making a noise then the con...

Страница 16: ...ocess A good welded connection is indicated by a clearly audible welding noise If the process passes off without making a noise then the connection is presumably of insufficient strength Blasting or r...

Страница 17: ...BE REPLACED WITH FUSES OF THE SAME TYPES AND VALUES THE GUARANTEE IS VOID IN THE EVENT OF EXCESSIVLY HIGH FUSING THE DEVICE MAY ONLY BE OPENED BY A QUALIFIED ELECTRICIAN 8 2 CARE OF THE OPTICAL COMPO...

Страница 18: ...nly in dry rooms 9 3 OPTICAL DATA MICROSCOPE Lens Ocular Working distance Magnification factor Field of view 1 0 10 x 140 mm 10 x 20 mm 9 4 TECHNICAL DATA LCD SHUTTER M11 BL Light shade Dark shade Swi...

Страница 19: ...load Tungsten inert gas welding Earthing Nominal welding current Power consumption under max load Power consumption under nominal load Cyclic duration factor Single phase transformer Keep away from wa...

Страница 20: ...Electrode clamped loosely in handpiece Tighten the clamping nut in the handpiece chap 11 no 38 by hand however tighten firmly 7 Oxidation and rusting Excessive gas pressure Reduce flow rate approx 2...

Страница 21: ...ty Clean or exchange protective glass Note Marks in the field of vision can also be caused by soiling in the interior of the oculars For this reason it is recommended to have the lenses cleaned by an...

Страница 22: ...e disposal of used electrical and electronic equipment discarded electrical devices must be separated and collected and sent for recovery in an environmentally friendly manner 13 EC DECLARATION OF CON...

Страница 23: ...ng devices Or you are searching for one or another tip on working with your PUK Then just sign up for our newsletter on www lampert info VISIT OUR SHOWROOM Our video library is showing many applicatio...

Страница 24: ...Born in Germany Lampert Werktechnik GmbH Ettlebener Stra e 27 D 97440 Werneck Tel 49 9722 9459 0 mail lampert info www lampert info Rev 1 0...

Отзывы: