background image

 

13 

  

TECHNICAL DATA 

 

  

7-1  TECHNICAL DATA 

 

  

   Device is suitable for spot and precision welding in dry 

environments 

 

  

 

 

Main Voltage 

~115 V / 50-60 Hz 
+/-15% 

  

 

 

Mains fuse 

T 6,3 A 

  

 

 

Power input   "PUK 3 professional plus" 

400 VA 

  

 

 

Power input   "PUK 3 professional" 

350 VA 

  

 

 

Operating voltage 

20 – 43 V 

  

 

 

No l- load voltage 

43 V 

  

 

 

Duty cycle 

80% 

  

 

 

max. charging time 

0,8 sek 

  

 

 

Inert gas 

min. ARGON 99,9% 
(ARGON 4.6) 

  

 

 

Maximum gas pressure 

4 bar 

  

 

 

Inert class 

  

 

 

Insulation class 

  

 

 

Protection Method 

IP 21S 

 

 

 

Weight  "PUK 3 professional plus" 

8,1 kg 

 

 

 

Weight  "PUK 3 professional" 

7,5 kg 

 
 

 

7-2

 

Identification Plate 

 

 

Symbol explanations: 

 

Amperage 

 

Voltage 

 

Protection 

Method 

 

 

 

Hertz 

 

Alternating 

Current (AC) 

 

Tungsten-Inert 

Gas-Welding 

 

 

 
 

Direct Current 

 

1 ~ 50-60Hz 

Power plug 

single phase / 

Alternating 

Current / 50-

60Hz 

 

 

Read the 

manual 

 

Idling Voltage 

 

Mains Voltage 

 

Ground 

 

Nominal 

Voltage 

 

Nominal 

welding current 

 

Single phase 

transformer 

 

Amperage 

input 

 

Rated 

Amperage 

input 

 

 

Duty cycle 

Содержание PUK 3 professional plus

Страница 1: ......

Страница 2: ......

Страница 3: ...liable for any damage caused by improper use and operation Before use please be sure to read the manual sections General Safety Requirements and Personal Protection and the separately attached Safety...

Страница 4: ...ts front side 6 4 3 Operations elements rear side 7 4 4 Starting up 7 9 5 SETTING OF THE PARAMETERS AND OPERATION 5 1 Adjustment of the Weldingparameter 9 5 2 Programming only PUK3 professional plus 1...

Страница 5: ...precious metal alloys on steel and steel alloys as well as titanium and various NE metals Not authorized for welding teeth fittings dental techniques Any usage other than given is prohibited Operatio...

Страница 6: ...circuit voltages are contained in your national and international regulations according to the type of welding current type of electrical source and the high or low hazard levels at the workplace If...

Страница 7: ...ours Bystanders close to the arcs also should be made aware of possible dangerous conditions and should wear protective equipment If necessary protective walls should be set up If welding in small roo...

Страница 8: ...ER DIAL ADJUSTABLE WELDING DIAL 7 CONNECTOR SOCKET FOR HAND PIECE 8 SOCKETS for connection of contact elements such as welding table welding clamp holding pliers 2 LCD DISPLAY 9 Output Po in per cent...

Страница 9: ...ECTION SOCKET FOR MICROSCOPE LIGHTING 12V 2A 19 INERT GAS CONNECTOR For a 6 0 mm pressure hose 20 Identification Plate 21 FUSE BOX Fuse box with space for spare fuses 4 4 STARTING THE WELDING PROCESS...

Страница 10: ...tion systems MEZZO welding microscope or PUK optics unit may be attached Other eye protection systems are not permissible and may lead to health damage Connect inert gas supply Attach the pressure con...

Страница 11: ...s Important We recommend beginners to always work within the blue range blue LED s Thus to change only the welding output 9 If you are familiar with the technology you can change of course also impul...

Страница 12: ...e Gapspot joint mode is also very well suitable for silver With this pulse shape even normally difficult weldable silver alloys can be welded with success 5 2 Programming Only PUK 3 professional plus...

Страница 13: ...he electrode from the work piece 6 2 IN GENERAL AND POINTERS Important Always work with sharpened electrodes This is the best way to achieve maximum results Make sure the work piece has enough contact...

Страница 14: ...ressure to the needle from the side as if you were scratching the surface of the work piece 6 3 SHARPENING THE ELECTRODES The electrodes should be sharpened with a diamond grinder with fine or medium...

Страница 15: ...99 9 ARGON 4 6 Maximum gas pressure 4 bar Inert class I Insulation class B Protection Method IP 21S Weight PUK 3 professional plus 8 1 kg Weight PUK 3 professional 7 5 kg 7 2 Identification Plate Sym...

Страница 16: ...ation Send device to be serviced 6 Welding unsatisfactory Wrong safety gas no inert gas Use inert gas Argon 4 6 7 Oxidation and soot development Gas pressure too high Reduce flow to ca 3 to 4 l min 8...

Страница 17: ...ines 89 336 EWG The Manufacturer Lampert Werktechnik GmbH Ettlebener Str 27 97440 Werneck Germany declares that the product Precision Welding Device PUK 3 professional PUK 3 professional plus conforms...

Страница 18: ...16 11 CONTACT Lampert Tools USA Inc 67 East Madison 512 Chicago IL 60603 Phone 1 866 478 5111 Fax 1 312 641 2678 info lampertusa com www lampertusa com...

Отзывы: