![Lampert M280 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/lampert/m280/m280_operating-manual_3422538009.webp)
© Lampert Werktechnik GmbH
2017
8
5.3 SWITCHING ON THE DEVICE
First, carefully open the gas
tank valve. Then switch the
master mains switch (2) on
the rear of the housing to the
“I”
position – the display
shows the safety prompt regarding eye protection and the
operating manual. Confirm your compliance with the safety
instructions by pressing one of the buttons.
5.4
ADJUSTING FOR THE CORRECT GAS FLOW
PLEASE CONSIDER THAT GOOD WELDING RESULTS CAN ONLY BE ACHIEVED WITH A CORRECTLY
ADJUSTED GAS FLOW.
In order to configure the correct gas flow, activate the "Gas
Test" (see chapter 5.5). This opens the gas valve in the
welding device. Now set the flow regulator to the correct
flow rate of approx. 2 – 3 litres/min. In doing so, also
observe the instructions provided with the flow regulator.
Once the gas flow is correctly adjusted, quit the "Gas Test"
by pressing the corresponding button.
5.5
OPERATING LEVEL "SETTINGS"
The "Settings" user level can be used to modify basic settings and launch various test functions.
•
Gas Test / Filter Test:
Pressing the
welding power
(+/-) buttons (23)
causes the
gas valve to be opened and
repeated switch-over of the eye protection filter from light to
dark. This function is important in order to set the correct
gas flow on the flow regulator (see chap. 5.4) and enables
correct function of the eye protection filter to be checked.
Pressing the buttons again causes the gas valve to be
closed and quits the gas / filter test.
•
Absorber:
Press the
welding power
(+/-) buttons (23) to enable
the optionally available absorber to be activated or
deactivated.
•
Welding signal tone:
Press the
welding power
(+/-)
buttons
(23)
to
activate or deactivate the acoustic signal that notifies the
triggering of the weld.
•
Language
:
The system can be toggled
between
German
and
English
by pressing the settings button (24).