4.5

 

INSERTING THE ELECTRODES INTO THE WELDING HANDPIECE: 

 

PLEASE ALWAYS CHECK THAT THE MACHINE IS SWITCHED OFF, PRIOR TO EXCHANGING THE 
ELECTRODES. THIS PREVENTS UNCONTROLLED TRIGGERING OF THE WELDING PROCESS. 

 

(Fig. 3) 
 
 
 
 
 
 
 
(Fig. 4) 

Lightly  rotate  the  nozzle  (10)  back  and  forth  and  in  doing 
so, pull it off of the handpiece (13). It is only pushed-on, not 
screwed in place. 

Release  the  threaded  electrode  connection  (12),  insert  a 
well  sharpened  tungsten  electrode  (11)  and  tighten  up 
(hand-tight – do not use a tool to tighten).  

 

Now replace the nozzle. 

The  electrode  must  protrude  approx.  4  -  6mm  out  of  the 
nozzle (Fig. 4).  

 

ONLY USE THORIUM OXIDE FREE ORIGINAL ELECTRODES 

 

Subsequently  insert  the  connector  of  the  handpiece  as 
straight  as  possible  into  the  socket  (Fig.  27,  p.  7)  on  the 
front  of  the  M280  and  fasten  in  place  by  tightening  the 

coupling  nut  hand-tight  in  a  clockwise  direction.  Insert  the 
connecting cable used into the socket (28) on the front side 
of the housing. 

 

 

 

4.6 CONNECT POWER SUPPLY: 

Insert the power cable with the mains connector into the 
corresponding socket (2) on the rear of the housing and 

insert the mains plug into a suitable socket with the correct 
mains voltage. 

 
CAUTION! 

AS SOON AS  THE  MASTER  MAINS SWITCH ON  YOUR 
„M280“  IS  SWITCHED  ON,  THE  VOLTAGE  IS  APPLIED 
TO THE CONNECTED CONTACT CLAMPS OR CABLES. 
IT IS  TO BE ENSURED THAT  THESE PARTS ARE NOT 
ALLOWED 

TO 

COME 

INTO 

CONTACT 

WITH 

ELECTRICALLY  CONDUCTIVE  OR  EARTHED  PARTS, 
SUCH AS THE HOUSING, ETC. IN DOING SO, THERE IS 
NO RISK FOR THE OPERATOR, WITH THE EXCEPTION 
OF  POSSIBLE  CIRCUMSTANCES  ARISING  FROM 
OPERATING ERROR. 

 
 

 

Содержание M280

Страница 1: ...Operating manual M280 TIG pulse welding device 8...

Страница 2: ...SE THE MANUFACTURER ACCEPTS NO LIABILITY FOR DAMAGES CAUSED THROUGH INAPPROPRIATE USE AND IMPROPER OPERATION THE GENERAL SAFETY REQUIREMENTS AND PERSONAL BODY PROTECTION CHAPTERS MUST BE READ BEFORE C...

Страница 3: ...ion of the onscreen symbols Pg 9 7 WELDING INSTRUCTIONS 7 1 Introduction for welding Pg 10 7 2 Welding with foot switch Optional accessory Pg 11 7 3 Basics and tips Pg 12 7 4 Resharpening the electrod...

Страница 4: ...dertaking any work on the system beyond minor manipulations where it is necessary to leave the workplace even for brief periods The highest and thus the most dangerous voltage in the welding circuit i...

Страница 5: ...NATION Never look into the LED lamp or its reflections without eye protection use protective shield or safety glasses with suitable protective glass SMOKES AND GASES When welding especially in small s...

Страница 6: ...coupling nut hand tight WARNING ONLY SUITABLE ORIGINAL EYE PROTECTION SYSTEMS FROM LAMPERT MAY BE CONNECTED TO THE WELDING SYSTEM OTHER EYE PROTECTION SYSTEMS ARE NOT APPROVED AND CAN LEAD TO PERMANE...

Страница 7: ...e connector of the handpiece as straight as possible into the socket Fig 27 p 7 on the front of the M280 and fasten in place by tightening the coupling nut hand tight in a clockwise direction Insert t...

Страница 8: ...ps DISPLAY 30 Material or welding program 31 Preselected welding situation geometry 32 Power output as a percentage 33 Foot switch display optional 34 Pulse duration in milliseconds ms 5 2 EXPLANATION...

Страница 9: ...is correctly adjusted quit the Gas Test by pressing the corresponding button 5 5 OPERATING LEVEL SETTINGS The Settings user level can be used to modify basic settings and launch various test function...

Страница 10: ...y thin materials or wires it is recommended to use a shorter welding time primarily when welding near to heat sensitive materials Welding times of no more than 4 ms are recommended here With copper al...

Страница 11: ...ety prompt by pressing any button The device is now ready for operation THE FOOT SWITCH CAN BE ACTIVATED BY PRESSING AND HOLDING IT APPROX 2 SEC A WHITE SYMBOL APPEARS IN THE DISPLAY Connect a metalli...

Страница 12: ...requires a minimum of maintenance under normal working conditions However it is essential that a few points are observed in order to guarantee the functionality and to keep the spot welding device ful...

Страница 13: ...eight 230 V 50 60 Hz 10 T 3 15 A 400VA 30 43 V 43 V 80 0 8 s min ARGON 99 996 4 bar I B IP 21S 6 5 kg 9 2 TYPE PLATE Explanation of pictographs Current Voltage Protection type Hertz Alternating curren...

Страница 14: ...ue to leakage current Switch device off and back on again If fault reoccurs arrange for servicing of device 4 Mains fuse blows or automatic circuit breaker trips Mains insufficiently fused or incorrec...

Страница 15: ...ecial local conditions Use special foot mat for the workspace 13 Device begins to weld immediately when touching the workpiece no gas pre flow Fault Immediately shut down the device arrange for servic...

Страница 16: ...17 15 13 EC DECLARATION OF CONFORMITY Please find enclosed to this shipment the separate document Declaration of Conformity Text and illustrations represent the technical status at the time of printin...

Страница 17: ...are searching for one or another tip on working with your M280 Then just sign up for our newsletter on www lampert info VISIT OUR SHOWROOM Our video library is showing many applications from everyday...

Страница 18: ...Born in Germany Lampert Werktechnik GmbH Ettlebener Stra e 27 D 97440 Werneck Tel 49 9722 9459 0 mail lampert info www lampert info Rev 1 0...

Отзывы: