19
GB
8.3 Clearances & dimensions
No shelf or overhang of combustible material should be closer than 650mm directly above the hob.
There must be a minimum clearance of 50mm between the rear edge of the hob and the rear wall. This clearance
must be maintained up to 650mm above the worktop (unless otherwise stated in your extractor manual).
Place the hob in the aperture, checking the hob is covering the worktop along all four sides. Set the front edge of the
appliance parallel with the front of the worktop.
Secure the hob to the worktop by means of the brackets provided, taking the thickness of the worktop into account.
Your appliance will be supplied and installed using the following installation method.
800mm
(+1)
50mm Min
50mm min
400mm min
650mm
520mm
(+1)
Minimum distance
between carcasses must
be equal to width of hob
50mm min between hob and rear wall
(>60mm to cut out aperture)
Instructions For Assembly
Instructions For Assembly