Installation
Installation and connection
Material damage!
The door and/or handle must not be used for lifting
or moving the appliance.
We recommend 2 people handling of the
product.
Use the handle slots located at both sides of
the oven to move the appliance.
Connection to the mains supply
This appliance must be earthed!
Howdens shall not be held responsible for any
damage caused by using the appliance without an
earthed connection.
Risk of electric shock
,
VKRUWFLUFXLWRUÀUHE\
unprofessional installation!
The appliance may be connected to the mains
VXSSO\RQO\E\DQDXWKRUL]HGTXDOLÀHGSHUVRQDQG
the appliance is only guaranteed after correct
installation.
Risk of electric shock
,
VKRUWFLUFXLWRUÀUHE\
damage of the mains lead!
The mains lead must not be clamped, bent, trapped
or come into contact with hot parts of the appliance.
If the mains lead is damaged, it must be replaced
E\DTXDOLÀHGSHUVRQ
The mains supply must correspond to the data
VSHFLÀHGRQWKHUDWLQJSODWHRIWKHDSSOLDQFH
The rating plate can be seen when the main
oven door is opened.
The appliance mains cable must correspond to
WKHVSHFLÀFDWLRQVDQGWKHSRZHUFRQVXPSWLRQ
VHH7HFKQLFDOVSHFLÀFDWLRQVSDJH
Risk of electric shock.
Before starting any
work on the electrical installation, please
disconnect the mains supply.
1.
This appliance must only be installed by a
TXDOLÀHGHOHFWULFLDQHJDORFDOHOHFWULFLW\
company or a NICEIC registered contractor,
to a suitable double-pole control unit with
a minimum contact clearance of 3 mm in
all poles. the work should be carried out
in accordance with IEE regulations. Failure
to observe this instruction may result in
operational problems and invalidation of the
appliance Guarantee.
Additional protection by a residual current circuit
breaker is recommended.
2.
Open the terminal block cover with
screwdriver.
3.
Pass the mains lead under the cable clamp
and secure clamp with the screw over the
outer cable insulation
4.
Connect the cables according to the supplied
diagram.
L
N
Terminal Block
Live: Brown
Earth: Green / Yellow
Neutral : Blue
Cable clamp
5.
Close the cover of the terminal block once the
wiring is complete. Mains cable must not be
longer than 2 metres for safety reasons.
6.
The mains lead should be routed away from
the appliance and not be trapped between the
appliance and the wall.