Built-in Single Fan Oven
LAM3412 LAM3413 LAM3414
Electrical connections
•
IMPORTANT:
Ensure that the electricity supply is switched off before
connecting. Your oven is intended for permanent installation.
• Your appliance must be connected to fixed wiring via the use of a
double pole switched fused spur outlet with at least 3mm contact
separation. The isolation switch must be accessible after installation
(see technical data for fuse rating). We recommend the use of an
RCD device as additional protection.
• We strongly recommend the appliance is connected by a qualified
electrician who will comply with the I.E.E and any local regulations.
• The terminology DOUBLE POLE - / + means that both the live and
neutral supplies are switched and disconnected at the same time.
• The terminations labelled SUPPLY are connections for the internal
house wiring and the terminations labelled LOAD are for connection
to the appliance.
•
IMPORTANT:
The wires in
the mains lead are coloured in
accordance with the following;
BLUE
= Neutral
BROWN
= Live
GREEN
/
YELLOW
= Earth
• As the colours of the wires in
the mains lead of this appliance
may not correspond with the
coloured markings identifying
the terminals in your spur box,
proceed as follows;
• The wire which is coloured
blue must be connected to
the terminal which is marked
with the letter ‘N’ or coloured
‘BLACK’. The wire which
coloured brown must be
connected to the terminal
which is marked with the letter
‘L’ or coloured RED. The green
and yellow earth ‘E’ should
be connected to the terminal
marked with the following
symbol .
BROWN
(Live)
BLUE
(Neutral)
GREEN
/
YELLOW
(Earth)