background image

Dear Customer,

Congratulations on your choice of a LAMONA domestic appliance.

The user manual will help you use your product quickly and safely. 

• 

Please read this user manual before installing and using the product.

• 

Always follow the safety instructions.

• 

Keep this user manual within easy reach for future reference. 

• 

Please read any other documents supplied with the product.

Explanation of symbols

Throughout this user manual the following symbols are used:

Important information or useful tips about usage.

Warning for possible hazards to health and property.

W

Metal Surfaces of the Extractor and Condensation

When cooking with pans using a large water content, large quantities of vapour and steam 

can be produced very quickly. This steam may condense onto the cold metallic surfaces of the 

extractor and even the splash back area if tiled, glazed etc. 

(This is not a fault with either the hob or extractor if correctly installed).

The amount of this condensation on any particular surface will depend on many factors including the 

ambient temperature in the kitchen, the related ambient temperature of the metal surfaces, the 

general ventilation within the kitchen, the type of food being cooked and the duration. Using lids on

pans can help reduce the amount of steam being released and subsequent condensation. 

This appliance is marked according to the European Directive 2012/19/EU on Waste

Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of

correctly you will help prevent potiential negative consequences for the environment 

and human health. The symbol on this product indicates that this product may not be

treated as household waste. Instead it should be handed over to the applicable 

collection point for recycling or electrical and electronic equipment.  Disposal must be

carried out in accordance with local environmental regulations for waste disposal. For 

more detailed information please contact your local council household waste site.

arning possibility of electric shock.

By placing the              marking on this product, we declare, on our own responsibility, compliance to all of 

European safety, health and environmental requirements stated in the legislation for this product.

Energy Efficiency

 

In order to optimise efficiency of the product and reduce environmental impact we recommend

 the following:

•    Product is installed in ducted configuration, using maximum Ø of ducting advised in this manual, 

      ducting as straight and as short as possible.

•    Any filters are cleaned/replaced when necessary to maintain good airflow and grease filter 

      efficiency.

•    Switch on the hood at the minimum speed required to clear unwanted cooking odours.

•    Switch off lighting when not in use or not required

.

Page _ 03

Exclusive to Howdens Joinery.co

User manual LAM2851

Содержание LAM2851

Страница 1: ...Instructions Installation LAM2851 T Box Island Hood www howdens com appliance registration...

Страница 2: ...See back page for product serial number...

Страница 3: ...sequent condensation This appliance is marked according to the European Directive 2012 19 EU on Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you wil...

Страница 4: ...intenance General cleaning Grease filters Carbon filters Replacing the lamps Installation Methods of extraction Extraction via ducting Extraction via recirculation Before beginning installation Instal...

Страница 5: ...ion Caution The appliance and its accessible parts can become hot during operation Children younger than 8 years old should stay away unless they are under permanent supervision The cooker hood must b...

Страница 6: ...removes odours from room but not steam The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels Make sure the ducting has no bends sharp...

Страница 7: ...and steam as with older hob technology The manufacturer refuses to accept any responsibilty for damage to or damages arising from failure to observe this instructions Ensure the ducting for cooker hoo...

Страница 8: ...Operation Control Panel Layout Extractor Contents Struts x 8 Reducer Remote control Ceiling plate Chimney sections Main body Cable grid Fixings Page _ 08 www howdens com LAMONA Appliances Timer Light...

Страница 9: ...eed 2nd Press MEDIUM speed 3rd Press HIGH speed Turning Off Decreasing Fan Speed Press the button and the motor begins to adjust to a lower setting and the LCD screen displays the speed If it is press...

Страница 10: ...ashing from one button to another the cooker hood is in connection mode The press any button on the remote control to confirm the connection The connection process is finished and the remote can be us...

Страница 11: ...rotect your kitchen furniture from greasy residues by out grease particles Over time the grease may become a risk if the greasy residue is allowed to build up To prevent a hazard the grease should be...

Страница 12: ...e The intervals between changing the filter will depend entirely upon the amount of cooking you do but on average they will last about 3 6 months To gain access to the carbon filter first of all remov...

Страница 13: ...n For extraction via recirculation attach carbon filter inside the hood Part reference LAM2002 switched off Remove the grease filters Turn the retaining clips to release the filter Insert new filter t...

Страница 14: ...able size for the chosen installation area In addition check whether there is an electrical socket available that will be accessible once the hood is mounted If the product is going to be used in extr...

Страница 15: ...hod 4 Build extractor body and frame top fixing or extractor body fixing method 5 Lift and fasten extractor to ceiling connect vent kit if applicable CAUTION HEAVY 6 Connect to a electrical point powe...

Страница 16: ...y slides over struts lift whole unit up to fasten to ceiling plate If ceiling height is more then 2 45m Extractor body fixing method 2 3 x persons fit slightly easier Plate struts fasten to ceiling ch...

Страница 17: ...Minimum Ceiling Height Possible Top Plate Fixing Use single struts Overall extractor height of c 630mm Height is suitable for recirculation installation Remove any loose dropped screws and nuts etc t...

Страница 18: ...length set to c 715mm Note Lowest strut jointing nuts and bolts need to be set c 270mm from the bottom of the strut to allow fixing to extractor body Remove any loose dropped screws and nuts etc to av...

Страница 19: ...plies are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the app...

Страница 20: ...lters Change carbon filters if applicable Change carbon filters if applicable Check installation Check extractor for any obvious issues Replace fuse reset breaker If you cannot eliminate the problem a...

Страница 21: ...urer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the p...

Страница 22: ...Product serial number Place sticker here ISSUE v1 190617...

Отзывы: