Electrical Connections
IMPORTANT: Ensure that the electricity supply is switched off before connecting.
Your appliance must be connected to
wiring via the use of a double pole switched fused spur outlet
with at least 3mm contact separation, The isolation switch must be accessible after installation. (See
technical data for fuse rating). We recommend the use of an RCD device as additional protection.
The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations
labelled LOAD are for connection to the appliance.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-
Blue.....................Neutral
Br
Green / Yellow............Earth
own..................Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your spur box, proceed as follows;
The wire which is coloured blue must be connected to the terminal which is marked with the letter
‘N’ or coloured BLACK. The wire which is coloured brown must be connected to the terminal which
is ma
connected to the terminal marked
rked with the letter ‘L’ or coloured RED. The wire which is coloured GREEN / YELLOW must be