Exclusive to Howdens Joinery.co
Page _ 13
User manual LAM2502 LAM2503
TROUBLESHOOTING GUIDE
Symptoms
Possible Cause
Solutions
Lamps fail to operate?
A replacement lamp is probably
necessary, but
check that the
lamp is correctly
into its holder.
(Remember that the lamps are not
covered by the guarantee.)
Disconnect the mains electricity supply before adjusting
or replacing the lamps.
The extractor lamps may become hot; therefore ensure
the bulb has cooled
before replacing.
Power is cut.
Check if there is power. Check the fuses in the fuse box. If
necessary, replace or reset the fuses.
The motor is on, but fan does
as usual?
Clogged
can reduce the
product’s
Check the grease
and charcoal
(if
also
ensure any venting is not obstructed?
Clean the grease
with warm water and mild
detergent, and/or replace any charcoal
The extractor works normaly
but smells linger?
Clogged
can reduce the
product’s
and may cause
unwanted smells.
Clean the grease
with warm water and mild
detergent, and/or replace any charcoal
Product does not operate?
The mains fuse maybe defective or
has tripped
Check fuses in the fuse box. If necessary, replace or
reset them.
Product is not connected properly.
Check all power connections.
If you cannot eliminate the problem after following the instructions in this section, consult your
depot or the Authorized Service Agent. Never try to repair a nonfunctional product yourself.
Troubleshooting
TECHNICAL INFORMATION
General
Total power consumption
140W
Fuse
3 A
Voltage /Frequency
220-240 V ~ 50 Hz
Cable type / section
0.75mm², 3 core or equivalent
Cable length
max. 1.5m
Lamps
G4 20W each