19_
LAMONA
Appliances
Electrical Connections
IMPORTANT: Ensure that the electricity supply is switched off before connecting. Your
hob
is
intended for permanent installation.
Your appliance must be connected to fi xed wiring via the use of a double pole switched fused spur outlet
with at least 3mm contact separation. The isolation switch must be accessible after installation (see
technical data for fuse rating). We recommend the use of an RCD device as additional protection.
We strongly recommend the appliance is connected by a
registered
Gas Safe Installer
who
will comply with the
appropriate Gas, I
.E.
C
and any
other
local regulations.
The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are connections for the internal house wiring and the terminations
labelled LOAD are for connection to the appliance.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-
Blue........ Neutral
Brown......Live
Green and Yellow.....Earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your spur box, proceed as follows;
The wire which is coloured blue must be connected to the terminal which is marked with the letter ‘N’ or
coloured ‘BLACK’. The wire which coloured brown must be connected to the terminal which is marked with
the letter ‘L’ or coloured RED. The green and yellow earth ‘E’ should be connected to the terminal marked
with the following symbol ‘
The appliance may be connected to the mains supply only by a
competent person.
The mains lead must not be clamped, bent, trapped, or come into
contact with hot parts of the appliance.
If the mains lead is damaged, it must be replaced by a qualifi ed
person (mains cable must not be longer than 2m for safety reasons). It
should be routed away from the appliance and not trapped between the
appliance and the wall.
N
L
L
N
LOAD
SUPPLY
LOAD
SUPPLY
DP
250V~
Blue.
(Neutral)
Brown.
(Live)
Green / Yellow.
(Earth)
L
N
Terminal
Live: Brown
Earth: Green /
Neutral :
Cable clamp