background image

 

o

 

If  the  room  where  the  extractor  is  to  be  used  contains  a  fuel 
burning  appliance  such  as  a  central  heating  boiler  then  its  flue 

must be of the sealed or balanced flue type. 

 

o

 

If other types of flue or appliances are fitted, ensure that there is 
an adequate supply of air in the room. 

 

o

 

When the extractor is being used in its extractor function, ensure 
that  the  ducting  is  fire  retardant  and  that  there  are  no  bends 

sharper than 90 degrees as this will reduce the efficiency of the 
hood.

 

 

 

o

 

Ensure  the  ducting  for  the  extractor  function  has  the  same 

diameter as the outlet hole all the way through.  

 

o

 

Keep  young  children  from  using,  playing  with 
or  tampering  with  the  cooker  hood.    Older 

children  and  infirm  persons  should  be 
supervised if they are using the cooker hood.  

 
 
 

o

 

Your extractor is for domestic use only. 

 

 
 

 

o

 

Please  dispose  of  the  packing  material  carefully  –  children  are 

especially vulnerable to it. 

 

o

 

Dirty oil is an even greater fire risk. 

 

 
 

 

o

 

Always  put  lids  on  pots  and  pans  when  cooking 
on a gas cooker. 

 
 

 

 

o

 

The  manufacturer  refuses  to  accept  any  responsibility  for 
damages  arising  to  the  extractor  or  it  catching  on  fire,  from  a 

failure  to  observe  the  fire  safety  advice  contained  in  this 
instruction booklet.  

o

 

Remember  that  when  in  extraction  mode,  your  extractor  is 
removing  air  from  your  room.    Ensure  that  proper  ventilation 

measures are being observed. 

  

 

Содержание HJA2480

Страница 1: ...60cm Extractor LAM2401 Black Instillation User Instruction HJA2480 Stainless Steel Issue 4 Apr 2012...

Страница 2: ...ing 10 The grease filters 10 Maintenance 11 13 Removing and cleaning the grease filters 11 Changing a light bulb 12 Fitting the carbon filters 13 Installation 14 22 Electrical connection 14 15 Before...

Страница 3: ...upply Cut off and render any plug useless Cut the cable off directly behind the appliance to prevent misuse This should be undertaken by a competent person o The packaging materials are environmentall...

Страница 4: ...ation Use Regulations the Building Regulations issued by the Department of the Environment the Building Standards Scotland Consolidated Regulations issued by the Scottish Development Department o It i...

Страница 5: ...all the way through o Keep young children from using playing with or tampering with the cooker hood Older children and infirm persons should be supervised if they are using the cooker hood o Your extr...

Страница 6: ...The lights on this appliance should only be used during operation of the extractor They should not be left on permanently and used as a lighting source o The extractor should not be exposed to a dire...

Страница 7: ...mm 933 mm Width 600 mm Depth 475 mm DIMENSIONS OF CHIMNEY SECTION 175 mm x 220 mm Your stainless steel extractor is fitted with o High extraction tangential motor o Push button control operation o 3...

Страница 8: ...2 62 dB If you are using the appliance in recirculation mode then PLEASE NOTE that some of the vent in the upper chimney section must be exposed You will have to take this into account when calculatin...

Страница 9: ...one water resistant film to protect the stainless steel surfaces To use your extractor o A ON OFF button o B Speed selection buttons Low speed Medium speed High speed o C Light on off button o Before...

Страница 10: ...r grill with mild liquid detergents and a new damp cloth o If you are using the appliance in recirculation mode then be sure to replace the carbon filters at the recommended intervals see section on F...

Страница 11: ...e and pulling them away from the extractor o Soak the grease filters in hot water and washing up liquid for about an hour o Rinse them off thoroughly with hot water o Repeat the process if required o...

Страница 12: ...cooled down o Find the bulb that requires replacement you will find it located in the light fixture which is inside the exposed section of the canopy o Unscrew the light bulb that needs to be replaced...

Страница 13: ...VE DISCONNECTED THE EXTRACTOR FROM YOUR MAINS SUPPLY 1 Remove the grease filters 2 Press the carbon filter against one end of the motor the fixing point is in the centre of the carbon filter 3 Turn th...

Страница 14: ...CTOR IS INTENDED FOR FITTED AND PERMANENT INSTALLATION o The extractor s power cable must be fitted upstream from the electrical connection using an omni polar switch with a contact distance of at lea...

Страница 15: ...g of the extractor o Ensure that all electrical connections are carried out by a suitably qualified person o Before commencing installation of the extractor the grease filters should be removed o Chec...

Страница 16: ...OW TO UNDERSTAND THE DIFFERENCES BETWEEN THESE TWO MODES o We recommend that at least two people install this extractor IMPORTANT YOUR EXTRACTOR SHOULD BE CONNECTED TO YOUR MAINS SUPPLY AFTER THE REST...

Страница 17: ...holes in the wall on the positions that you have marked in step 2 4 Insert rawl plugs into all of the holes that you have drilled 5 Fasten the support screws halfway in leaving them 10 mm out of the w...

Страница 18: ...18 7 Fully tighten the support screws A and then screw the anchoring screws B through the relevant holes in the extractor Fully tighten the anchoring screws into the wall...

Страница 19: ...ross section of at least 150 cm o The maximum distance between the coupling and your discharge outlet should be 3 metres with one 90 degree bend For each additional 90 degree bend the maximum distance...

Страница 20: ...ide measurements of both sides of chimney section D on the wall with a pencil and then remove chimney section D 11 Take the flat bracket E and place it between the two pencil marks that you made in st...

Страница 21: ...the extractor and fix it using the two screws that are supplied o Secure the top of chimney section C to the flat bracket using the screws provided o Slide chimney section D inside of chimney section...

Страница 22: ...mode What is the difference between extraction and recirculation modes o To get optimum performance from your extractor the air will be taken out of the room via external ducting o Unfortunately if yo...

Страница 23: ...chen is not well ventilated enough o If the extractor is set up for recirculation mode check that the carbon filters do not need replacing o If the extractor is set up for extraction mode check that t...

Страница 24: ...24 Your Guarantee...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28...

Отзывы: