5  ASSEMBLY 

 

5.1  General notes 

 

Here are some general recommendations to follow in order to prevent accidents or damage to the 

product: 

  Unpacking and installation must be performed by at least two people. 

 

All handling operations must be carried out using appropriate means and in full compliance 

with safety regulations. 

 The positioning of the packed product must be maintained in accordance with the guidelines supplied 

by pictograms and written on the packaging. 

  If using ropes, straps, chains, etc., make sure they are suitable for the weight to be unloaded and are 

in good condition. 

 When moving the package, move with slow and continuous movements to avoid tearing the ropes, 

chains, etc. 

  Do not tilt excessively in order to avoid overturning. 

  Do not stand within range of the loading/unloading means (forklifts, cranes, etc.). 

 

5.2  Unpacking 

Unpack the product being careful not to damage or scratch it. Remove the accessory package and any 

pieces of polystyrene or cardboard used to block removable parts, etc. from the stove furnace. Also 

remember not to leave packaging components (plastic bags, polystyrene, etc.) within the reach of 

children, as they could be potential sources of danger. Dispose of them according to regulations.

 

 

6  USE 

 

All local regulations, including those relating to national and European regulations, must be observed when 

installing the unit. 

Do not use the unit as an incinerator or in any other way other than that for which it was designed. No 

other fuel besides wood pellets must be used. 

Do not use liquid fuels. 

When the stove is turned on, it can reach extremely high temperatures to the touch, especially its outer 

surfaces. Operate carefully to avoid burns. 

Do not make any unauthorized modifications to the device. 

Only use original replacement parts recommended by the manufacturer. 

 

In general 

  Make sure that the room where the stove is to be installed offers sufficient ventilation (see section ''1.3 

External air intake vent''). 

  Make sure that all exhaust system joints are hermetically sealed with silicone (no cementing), are 

resistant to heat (250 °C) and are not damaged. 

  Periodically check (or have someone check) the cleanliness of exhaust fumes. 

 

CAUTION: keep all flammable products well away from the stove when it is operating (MINIMUM: 

100 cm from the front wall). 

 

CAUTION: to prevent the escape of fumes, the combustion chamber must be kept closed except 

during cleaning operations, to be carried out with the stove off. 

 

CAUTION: removing the safety guard inside the tank is strictly prohibited. 

 

CAUTION: in the event of pellet supply while the stove is on, make sure that pellets are not 

finished and that the flame remains present in the brazier. Also avoid the fuel sack from coming 

into contact with hot surfaces. 

 

CAUTION: remove any residue of unburned pellets caused by failed ignitions before you start 

the stove again. 

 

CAUTION: if during the ignition phase, the stove does not start and you notice a lot of smoke in 

the combustion chamber, immediately turn off the stove and replace the pellets being used, as 

Содержание Jessica Natural SN

Страница 1: ...e The instruction manual is an integral part of the product Laminox S r l reserves the right to change the characteristics and data reported in the following document at any time and without warning i...

Страница 2: ...gloves to avoid leaving difficult to remove fingerprints for the first cleaning Stove installation must be performed by at least two people Connect the stove to the mains only after proper profession...

Страница 3: ...nces for positioning air intake vents Non hermetic installation 11 4 5 Fume exhaust duct 12 4 6 Using an external fume duct 14 5 ASSEMBLY 15 5 1 General notes 15 5 2 Unpacking 15 6 USE 15 6 1 Componen...

Страница 4: ...xhaust pipe of the stove and a height no less than the one stated see table 2 Never use two stoves a fireplace and a stove a stove and a wood stove etc in the same room since the draft of one could da...

Страница 5: ...tructed so as to prevent penetration into the flue of rain snow or foreign bodies and so that in the event of winds in any direction and at any angle it assures the discharge of combustion products wi...

Страница 6: ...ts set out in the paragraphs above The adjacent room cannot be used as a garage for storage of combustible material or for activities involving a risk of fire 1 4 External air intake vent Hermetic ins...

Страница 7: ...ncy 88 5 Recommended draft 3 6 Pa Hopper capacity 15 Kg Smoke outlet 120 mm Weight 114 Kg Dimension LxPxH 572 x 553 x 1151 mm 2 3 Product identification data The technical label shows device data and...

Страница 8: ...and horizontal splits Since pellet characteristics and quality greatly influence the autonomy efficiency and proper operation of the stove we recommend AVOID using pellets with dimensions different fr...

Страница 9: ...d Boilers must be installed in a technical room It is forbidden to install them in open verandas or outdoors Installation in rooms containing other generators that collect air from the environment is...

Страница 10: ...lammable material Minimum distance in air from the flammable rear wall P 200 mm Minimum distance in air from the flammable side wall P 200 mm Frontal distance from flammable material R 1000 mm 4 2 3 D...

Страница 11: ...and have a thickness of at least 2 mm Fig 5 and 6 Fig 5 Fig 6 4 4 Minimum distances for positioning air intake vents Non hermetic installation Pellet stove combustion air intake vents cannot be connec...

Страница 12: ...50 C and are to be secured with a 3 9mm self tapping screw The installation of dampers or valves which may obstruct the passage of exhaust fumes is prohibited Installation in a chimney flue where exha...

Страница 13: ...ich is flammable or has flammable parts 100 320 Concrete wall or roof 50 220 Brick wall or roof 30 180 4 5 4 Using a traditional type chimney flue If you wish to use an already existing chimney flue i...

Страница 14: ...s steel secured to the building Fig 9 should be used An inspection area should be created at the base of the duct for performing periodic checks and maintenance It should be equipped with a windproof...

Страница 15: ...other than that for which it was designed No other fuel besides wood pellets must be used Do not use liquid fuels When the stove is turned on it can reach extremely high temperatures to the touch esp...

Страница 16: ...unburned pellets IMMEDIATELY TURN OFF the stove and contact the service centre CAUTION pay the utmost attention when children are present to prevent them from standing in front of the stove 6 1 Compo...

Страница 17: ...end until the brazier is filled 2 Lift the pin located on the top of the stove using the starting lever provided and turn it to the locked position Fig 21 22 Fig 21 Fig 22 CAUTION Always remove the st...

Страница 18: ...on Max Minimum power position Min Fig 25 6 5 Shutdown By moving the lever in position 1 fig 21 the fall of pellet into the brazier will stop combustion will continue for about 20 minutes after which t...

Страница 19: ...or otherwise locally dispersed they should be retained in the closed container until all conders have been thoroughly cooled CAUTION ashes keep embers on for a long time 7 3 Brazier cleaning When the...

Страница 20: ...tened with water to clean metal stove parts Never clean metal or ceramic parts with alcohol thinners petrol ketones or other degreasers Use of these substances frees the company from all liability Dis...

Страница 21: ...Clean fans thoroughly 7 13 Routine and special maintenance These operations should be programmed ANNUALLY with a Technical Assistance Centre and are necessary to ensure the maintenance of product eff...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Laminox S r l Hydro Division Zona Industriale Callarella 261 263 62028 SARNANO MC Italy Tel 39 0733 657 622 Fax 39 0733 657 494 www laminox com e mail export laminox com Jessica SN rev 07 2022...

Отзывы: