(1460x) PROFESSIONAL-IX 3.0    

 

Operating Instructions 

Operating Instructions
Wind Sensors PROFESSIONAL-IX 3.0

2.6.5 Earthing

To improve the operating security in lightning-prone areas 
we suggest an additional earthing of the sensors via the inte-
grated earthing screw of the PROFESSIONAL-IX 3.0.
The following illustration shows the steps of installation of 
an earthing connection with a cable clip and earthing screws 
onto the sensor.

Figure: Example of an earthing cable

2.6.6  Power and signal connection 

The PROFESSIONAL-IX sensors dispose of separate con-
nections for the heating supply and for the supply and signal 
transmission of the sensor.

2.6.7   Connection of sensor electronic

PROFESSIONAL-IX sensors will be connected to a data 
measuring system via the open cable end (see chapter 5).
The connecting cable is suitably installed along the mast 
between the data evaluation device (indicating instrument or 
data acquisition system) and the sensor. The cable must be 
secured using appropriate cable ties (length depends on the 
mast diameter).
The cable routing should be arranged in accordance with the 
installation site. Make sure that the cable is secured by suit-
able cable binders. 

For further details about the electrical connection of the sensor 
please see paragraph „Dimensional drawings and electrical 
connections“.

Lead the cable in a wide curve from the mast to the 
bottom of the casing so that you can later easily 
dismount the cable. 

Please make sure the cable is protected from humidity on the 
side of the data processing system resp. the power supply. 
Generally, cable sockets that use a rubber joint to prevent 
humidity from penetrating into the terminal box of the data 
processing system provide suf

fi

 cient protection.

To reduce the risk of inductive interference the ca-
ble must be properly grounded (screening on both 
sides).

2.6.8 Safety 

instructions

As the sensor is often mounted at considerable 
heights, the appropriate safety instructions need 
to be observed in the course of mounting. During 
electrical installation works the respective AC/DC 
must be switched off.

Please note that the sensor head can be very 
hot!

The housing must not be opened by unauthorized 
personnel!

3 Maintenance

The sensor design permits long periods of maintenance-free 
operation. 
We recommend a regular visual veri

fi

 cation and functional 

test of the wind sensors. 
In case of speci

fi

 c problems or dif

fi

 culties do not hesitate to 

contact our LAMBRECHT service under:

Tel.: +49-(0)551-4958-0
Fax: +49-(0)551-4958-327
E-Mail: [email protected]

For the long-term assurance of the function and accuracy of  
the proposed components, we are pleased to offer you our 
professional maintenance and calibration services.

4 Transports

In case it is necessary to ship or to transport the sensor, the 
instrument must be carefully packed to prevent mechanical 
in

fl

 uences or other damages. It is recommended to use the 

original packing. 

5

Содержание PROFESSIONAL-IX 3.0

Страница 1: ...inciples for mast flange or bore for high flexibility Heating supplied separately from sensor electronic for operation at lowest temperatures Integrated 125 watt heating for optimal heating of the mov...

Страница 2: ...icefall rockfall vandalism 2 Impacts or damages caused by over voltages or elec tromagnetic fields which are beyond the standards and specifications in the technical data 3 Damages caused by improper...

Страница 3: ...If the sensor is installed on a roof top the place of instal lation must be in the middle of the roof to avoid predominant wind directions If you want to measure both wind direction and wind speed the...

Страница 4: ...ss for installation of the sensor between the nuts may be max 10 mm Mounting is to be made in the fol lowing steps 1 Remove the lower thread nut from the sensor 2 The sensor has to be inserted into th...

Страница 5: ...rom the mast to the bottom of the casing so that you can later easily dismount the cable Please make sure the cable is protected from humidity on the side of the data processing system resp the power...

Страница 6: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 5 Dimensional drawings and electrical connections 6...

Страница 7: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 Electrical connections 7...

Страница 8: ...easuring range 0 360 Accuracy 1 Resolution 1 Starting value 0 4 m s Output Id No 00 14601 300 000 0 20 mA 0 360 Id No 00 14601 300 004 4 20 mA 0 360 Id No 00 14601 300 004 0 10 V 360 degr Parameter wi...

Отзывы: