Lambrecht PROFESSIONAL-IX 3.0 Скачать руководство пользователя страница 4

(1460x) PROFESSIONAL-IX 3.0    

 

Operating Instructions 

Operating Instructions
Wind Sensors PROFESSIONAL-IX 3.0

Masts or tubes (grounded) suitable for mounting have an outer 
diameter of Ø 48-50 mm. A mast adapter (see accessories) 
is necessary. 

Mounting of the adapter at the wind sensor: 

1.  Remove both thread nuts from the sensor.

2.  Insert the sensor into the bore (Ø 30 mm) of the adapter. 

3.  Fasten the sensor with the 

fl

 at side of a detached nut from 

the lower side. Tighten with a suitable tool (wrench size 
36), until a twisting safety of the sensor is given. 

Mounting of the wind sensor at the mast: 

1.  Install the cable with plug connection inside the mast.

2.  Connect the cable with the sensor and screw down the 

locking nut of the cable gland. 

3.  Put the sensor on the mast (tube). With regard to the wind 

direction sensor the north mark on the sensor must be 
aligned to the geographical north direction acc. to 2.6.4. 
Afterwards fasten the locking screw in the mast adapter 
to give the sensor a 

fi

 xed and torsion-free 

fi

 t. 

Proceed analogously when mounting the sensor on a tube 
traverse. 

2.6.2  Mounting on traverse with slotted bore  
 hole

At each end of the traverse (Id-No. 32.14567.010 000) there 
are slotted bores with a diameter of 30 mm.
1.  Remove the lower nut from the sensor.

2.  Put a sensor with assembled cable sidewise into the 

bore.

3.  Fasten the sensor with the 

fl

 at side of the detached nut 

from the lower side. Tighten with a suitable tool (wrench 
size 36), until a twisting safety of the sensor is given.

2.6.3  Mounting on traverse with 30 mm-bore  
 hole

Material thickness for installation of the sensor between the 
nuts may be max. 10 mm. Mounting is to be made in the fol-
lowing steps: 
1.  Remove the lower thread nut from the sensor.

2.  The sensor has to be inserted into the bore and fastened 

by the opposite side with the loose nut (removed as under 1.). 
With regard to the wind direction sensor the north mark 
on the sensor must be aligned to the geographical north 
direction acc. to 2.6.4 before 

fi

 nally fastening the nut.

2.6.4  North alignment of wind vane

For wind direction measurements the north mark on the sen-
sor must be aligned to the geographical north direction.
To set up the sensor’s north orientation select a landmark 
which is as far as possible up north with regard to the 

fi

 nal 

position of the wind direction sensor.
The reference point can be selected using a topographical 
map (1:25000). The exact position of the reference point is 
determined using an amplitude compass that can be adjusted 
horizontally on a stand.
You have to turn the wind vane’s marking exactly over the 
marking at the sensor shaft. When you have aligned the 
marks, you may 

fi

 x the wind vane with e.g. a piece of adhesive 

tape. When you have 

fi

 xed the wind vane you can locate the 

reference point by aiming at it over the axis. Now you must 
turn the sensor casing on the mounting tube until the tip of the 
wind vane points to the reference point in the north.
This requires that the sensor is easily turnable on the mount-
ing part. The sensor has to be 

fi

 xed in this position. 

Forceful turning of the mounted sensor can 
damage the instrument! 

After alignment the adhesive tape has to be removed.

For precise north alignment compass declina-
tion have to be considered!

Note: Follow all safety instructions while setting up 
the sensor onto a mast.

4

Содержание PROFESSIONAL-IX 3.0

Страница 1: ...inciples for mast flange or bore for high flexibility Heating supplied separately from sensor electronic for operation at lowest temperatures Integrated 125 watt heating for optimal heating of the mov...

Страница 2: ...icefall rockfall vandalism 2 Impacts or damages caused by over voltages or elec tromagnetic fields which are beyond the standards and specifications in the technical data 3 Damages caused by improper...

Страница 3: ...If the sensor is installed on a roof top the place of instal lation must be in the middle of the roof to avoid predominant wind directions If you want to measure both wind direction and wind speed the...

Страница 4: ...ss for installation of the sensor between the nuts may be max 10 mm Mounting is to be made in the fol lowing steps 1 Remove the lower thread nut from the sensor 2 The sensor has to be inserted into th...

Страница 5: ...rom the mast to the bottom of the casing so that you can later easily dismount the cable Please make sure the cable is protected from humidity on the side of the data processing system resp the power...

Страница 6: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 5 Dimensional drawings and electrical connections 6...

Страница 7: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 Electrical connections 7...

Страница 8: ...easuring range 0 360 Accuracy 1 Resolution 1 Starting value 0 4 m s Output Id No 00 14601 300 000 0 20 mA 0 360 Id No 00 14601 300 004 4 20 mA 0 360 Id No 00 14601 300 004 0 10 V 360 degr Parameter wi...