Lambrecht METEOROLOGY 14576-24 V Скачать руководство пользователя страница 1

1

(145x6) 

METEOROLOGY 

   Operating 

Instructions

Operating Instructions
Wind Sensors METEOROLOGY (145x6)

Versions

The METEOROLOGY family of sensors comprises the heated 
sensors 14576-24 V for wind speed and 14566-24 V for wind 
direction as well as the unheated sensors 14576 I (wind 
speed) and 14566 F1000 (wind direction).

Measuring Elements

The heated models use optoelectronic measuring elements to 
detect, without any wear, the rotation of the cup anemometer 
and the wind vane, respectively.

The unheated models use measuring elements with extremely 
low friction to detect rotations; this also guarantees a long 
service life.

Cup Anemometer

The three-armed cup anemometer with a diameter of 215 mm 
is rotated by the wind. The number of revolutions is a measure 
of the wind speed. 

The cup anemometer’s constructive features that are per-
manently controlled by the quality management during the 
manufacturing process ensure optimum linearity.

Wind Vane

The single-bladed wind vane has a great radius so that even 
small wind speeds move the wind vane to the corresponding 
wind direction. 

The size and form of the wind vane are optimized for a low 
starting value, and an excellent compromise regarding its 
dynamic properties (inertia, proper frequency) has been 
achieved.



Содержание METEOROLOGY 14576-24 V

Страница 1: ...with extremely low friction to detect rotations this also guarantees a long service life Cup Anemometer The three armed cup anemometer with a diameter of 215 mm is rotated by the wind The number of re...

Страница 2: ...ny mutual influence of the sensors A wind sensor pair easily meets this requirement since the sensors are set up side by side Their horizontal distance should be approximately 1 5 m The two sensors mu...

Страница 3: ...nt dependent switching or monitoring points 2 a Switching point The amplifier switching point must be within a proximity switch current consumption range of 1 2 mA to 2 1 mA 2 b Cable damage monitorin...

Страница 4: ...the wind vane this way you can locate the reference point by aiming at it over the axis Now you must turn the sensor casing on the mounting tube until the tip of the wind vane points to the reference...

Страница 5: ...ignement Id No 32 14565 060 xxx Coupler socket Id No 65 53070 470 100 View of the socket from the solder side View of the socket from the plug side View of a cable end The single leads of the cabel ar...

Страница 6: ...6 145x6 METEOROLOGY Operating Instructions Operating Instructions Wind Sensors METEOROLOGY 145x6 14576 I Id No 00 14576 010 000 14576 24V Id No 00 14576 250 004 Dimensions...

Страница 7: ...14566 24V Id No 00 14566 200 30 Wind tunnel results DWD Hamburg Wind speed sensor 14576 24V Instantaneous value v Measured frequence f m s Hz 0 30 0 1 07 7 5 2 10 16 5 4 95 45 9 82 93 14 75 142 19 80...

Страница 8: ...cup rotor 210 mm R80 Weight approx 0 4 kg approx 0 4 kg Other delivered with 12 pin plug and integrated transducer delivered with 12 pin plug No 00 14566 200 304 00 14566 000 030 Code 14566 24V 14566...

Отзывы: