background image

Manual
Wind Sensors INDUSTRY Modbus

(14567/14577) INDUSTRY Modbus 

Manual

INDUSTRY Modbus · Advantages

The INDUSTRY Modbus wind sensors are very economical 
to purchase. The sensors also impress with their high ac-
curacy, simple mounting principles and seawater-resistant, 
very robust materials.

The thermal decoupling of the housing shaft enables optimum 
heating of the sensor head and minimum power requirement 
of the system.

•  proven sensor technology
•  very good starting values
•  large measuring and temperature application ranges
•  easy mast mounting 
•  optimal heating concept

Content

1. 

Initial operation

2. 

Principles of installation

3. 

Setting up the North Direction 

 

for the wind direction sensor

4. 

Electrical connection

5. 

Heating

6. 

Maintenance

7. 

Wiring diagram

8. 

Dimensioned drawings

9. 

Modbus-protocol

9.1 

Data encoding 

9.2 

Device-address

9.3 

Standard confi guration - Default

9.4 

Modbus command set

9.5 

Measured value and parameter registers

9.6 

Sensor parameters / Confi guration parameters

9.7 

Mapping register for autoconfi guration 

9.8 

Autoconfi guration

9.8.1 

Mapping register INDUSTRY Modbus

10. 

Technical data

1

Содержание INDUSTRY Modbus

Страница 1: ...good starting values large measuring and temperature application ranges easy mast mounting optimal heating concept Content 1 Initial operation 2 Principles of installation 3 Setting up the North Dire...

Страница 2: ...lower edge of the upper wind speed sensor is 0 1 to 0 5 m above the upper edge of the lower wind direction sensor 2 Principles of installation Attention Because the installation takes place in a dang...

Страница 3: ...measurements the north mark on the sen sor must be aligned with the geographical north direction You have to turn the marking exactly over the marking at the sensor shaft When you have aligned the mar...

Страница 4: ...14567 14577 INDUSTRY Modbus Manual Wind Sensors INDUSTRY Modbus Manual 14567 14577 INDUSTRY Modbus Manual 7 Wiring diagram 4...

Страница 5: ...Manual Wind Sensors INDUSTRY Modbus 14567 14577 INDUSTRY Modbus Manual 8 Dimensioned drawings Accessories optional 14567 U6 Mast adapter Id No 32 14567 006 000 5...

Страница 6: ...s 0x1234 is transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 9 2 Device address The address...

Страница 7: ...al place INT 30202 Wind direction average value since last retrieval 10 1 decimal place INT 30203 Wind direction maximum value 10 1 decimal place INT 30204 Wind direction minimum value 10 1 decimal pl...

Страница 8: ...perature If the autocon guration is started with the data logger met LOG it queries the available mapping registers on each COM interface in the device address range 1 25 For this purpose the number o...

Страница 9: ...Endian WORD 31592 Global radiation instantaneous values Low WORD uncompensated 0x04 Big Endian WORD 9 8 1 Mapping register INDUSTRY Modbus Register address Register value Unit Factor Description 4600...

Страница 10: ...0 7 50 m s Accuracy 2 0 5 m s at 0 7 5 m s and 2 FS at 5 02 50 m s Resolution 1 0 02 m s Starting value 0 7 m s 0 7 m s Interface RS485 RS485 Protocol Modbus RTU Modbus RTU Weight 0 35 kg 0 25 kg Mea...