background image

Manual
Wind Sensors INDUSTRY Modbus

(14567/14577) INDUSTRY Modbus 

Manual

31501 Global radiation 

instantaneous values 
(High-WORD)
(temperature compen-
sated)

W/m²

100

2 decimal places
Registers 31501 + 31502 can 
only be read out together 
(function code 0x04)

LONG

0x04

Big-Endian 
WORD

31502 Global radiation 

instantaneous values 
(Low-WORD)
(temperature compen-
sated)

0x04

Big-Endian 
WORD

31591 Global radiation 

instantaneous values 
(High-WORD)
(uncompensated)

W/m²

100

2 decimal places
Registers 31591 + 31592 can 
only be read out together 
(function code 0x04)

LONG

0x04

Big-Endian 
WORD

31592 Global radiation 

instantaneous values 
(Low-WORD)
(uncompensated)

0x04

Big-Endian 
WORD

9.8.1  Mapping register INDUSTRY Modbus

Register 
address

Register value

Unit

Factor

Description

46001

30001 Register address 1

Wind speed instantaneous value

INT

46002

30002 Register address 1

Wind speed average value since last retrieval

INT

46003

30003 Register address 1

Wind speed maximum value 

INT

46004

30004 Register address 1

Wind speed minimum value

INT

46005

30201 Register address 1

Wind direction instantaneous value

INT

46006

30202 Register address 1

Wind direction average value since last retrieval

INT

46007

30203 Register address 1

Wind direction maximum value

INT

46008

30204 Register address 1

Wind direction minimum value

INT

9

Содержание INDUSTRY Modbus

Страница 1: ...good starting values large measuring and temperature application ranges easy mast mounting optimal heating concept Content 1 Initial operation 2 Principles of installation 3 Setting up the North Dire...

Страница 2: ...lower edge of the upper wind speed sensor is 0 1 to 0 5 m above the upper edge of the lower wind direction sensor 2 Principles of installation Attention Because the installation takes place in a dang...

Страница 3: ...measurements the north mark on the sen sor must be aligned with the geographical north direction You have to turn the marking exactly over the marking at the sensor shaft When you have aligned the mar...

Страница 4: ...14567 14577 INDUSTRY Modbus Manual Wind Sensors INDUSTRY Modbus Manual 14567 14577 INDUSTRY Modbus Manual 7 Wiring diagram 4...

Страница 5: ...Manual Wind Sensors INDUSTRY Modbus 14567 14577 INDUSTRY Modbus Manual 8 Dimensioned drawings Accessories optional 14567 U6 Mast adapter Id No 32 14567 006 000 5...

Страница 6: ...s 0x1234 is transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 9 2 Device address The address...

Страница 7: ...al place INT 30202 Wind direction average value since last retrieval 10 1 decimal place INT 30203 Wind direction maximum value 10 1 decimal place INT 30204 Wind direction minimum value 10 1 decimal pl...

Страница 8: ...perature If the autocon guration is started with the data logger met LOG it queries the available mapping registers on each COM interface in the device address range 1 25 For this purpose the number o...

Страница 9: ...Endian WORD 31592 Global radiation instantaneous values Low WORD uncompensated 0x04 Big Endian WORD 9 8 1 Mapping register INDUSTRY Modbus Register address Register value Unit Factor Description 4600...

Страница 10: ...0 7 50 m s Accuracy 2 0 5 m s at 0 7 5 m s and 2 FS at 5 02 50 m s Resolution 1 0 02 m s Starting value 0 7 m s 0 7 m s Interface RS485 RS485 Protocol Modbus RTU Modbus RTU Weight 0 35 kg 0 25 kg Mea...

Отзывы: