Manual
Weather Sensor EOLOS-IND Modbus
(1643) EOLOS-IND Modbus
Manual
9
Mapping Register EOLOS-IND Modbus
Register
address
Register value
Unit
Factor
Description
46001
30001 Register address 1
Wind speed instantaneous value
INT
46002
30002 Register address 1
Wind speed mean value since last retrieval
INT
46003
30003 Register address 1
Wind speed maximum value
INT
46004
30004 Register address 1
Wind speed minimum value
INT
46005
30201 Register address 1
Wind direction instantaneous value
INT
46006
30202 Register address 1
Wind direction mean value since last retrieval
INT
46007
30203 Register address 1
Wind direction maximum value
INT
46008
30204 Register address 1
Wind direction minimum value
INT
46009
30401 Register address 1
Air temperature instantaneous value
INT
46010
30402 Register address 1
Air temperature mean value since last retrieval
INT
46011
30403 Register address 1
Air temperature maximum value
INT
46012
30404 Register address 1
Air temperature minimum value
INT
46013
30601 Register address 1
Humidity instantaneous value
INT
46014
30602 Register address 1
Humidity mean value since last retrieval
INT
46015
30603 Register address 1
Humidity maximum value
INT
46016
30604 Register address 1
Humidity minimum value
INT
46017
30701 Register address 1
Dew point instantaneous value
INT
46018
30702 Register address 1
Dew point mean value since last retrieval
INT
46019
30703 Register address 1
Dew point maximum value
INT
46020
30703 Register address 1
Dew point minimum value
INT
46021
30801 Register address 1
Air pressure instantaneous value
INT
46022
30802 Register address 1
Air pressure mean value since last retrieval
INT
46023
30803 Register address 1
Air pressure maximum value
INT
46024
30804 Register address 1
Air pressure minimum value
INT
46025
33560 Register address 1
Abs. humidity instantaneous value
INT
46026
33561 Register address 1
Abs. humidity mean value since last retrieval
INT
46027
33562 Register address 1
Abs. humidity maximum value
INT
46028
33563 Register address 1
Abs. humidity minimum value
INT
46029
33580 Register address 1
QFE instantaneous value
INT
46030
33581 Register address 1
QFE mean value since last retrieval
INT
46031
33582 Register address 1
QFE maximum value
INT
46032
33583 Register address 1
QFE minimum value
INT
46033
33584 Register address 1
QNH instantaneous value
INT
46034
33585 Register address 1
QNH mean value since last retrieval
INT
46035
33586 Register address 1
QNH maximum value
INT
46036
33587 Register address 1
QNH minimum value
INT
46037
33588 Register address 1
QFF instantaneous value
INT
46038
33589 Register address 1
QFF mean value since last retrieval
INT
46039
33590 Register address 1
QFF maximum value
INT
46040
33591 Register address 1
QFF minimum value
INT
Note:
For each measurement type, the values from the registers with the maximum values (3XXX3) and minimum
values (3XXX4) are automatically reset as soon as the register with the mean values (3XXX2) has been read out.
For example, reading 30402 resets registers 30403 and 30404.
12