Lambrecht ARCO-Modbus Скачать руководство пользователя страница 4

Manual
Combined Wind Sensor ARCO-Modbus

(14581) ARCO-Modbus

Manual

The reference point can be selected using a topographical 
map (1:25000). The exact position of the reference point is 
determined using an amplitude compass that can be adjusted 
horizontally on a stand.

The compass declination has to be considered!  

A functional check at three points off set by 90° directions is 
recommended.

Follow all safety instructions while setting up the 
sensor on to a mast.

2.8.2  Power and signal connection

If the sensor is mounted in the correct manner and con-
nected with the right cable (accessory), you can attach the 
wires for the power supply and signal outputs to the data 
acquisition equipment (computer).

The ARCO sensor requires a 4-pole M12 plug connector. 
The cable shield should be connected with both ends at the 
ground wire (PE).

To reduce the risk of inductive interference the sen-
sor must be properly grounded (screening on both 
sides).

The external connection is carried out via a central connec-
tor which is located in the housing base. For further details 
about  the electrical connection please see section "Electrical 
connections“.
The typical power supply of the sensors is 24 VDC with a 
current consumption of max. 920 mA (incl. heating). The 
input voltage range can be 20...28 VDC. The heating of the 
ARCO-Modbus has a heating power of 2-9 W.
Under most climatological conditions the heating prevents 
blocking of the moving sensor parts. Neither the cup rotor nor 
the wind vane are heated. In the case of icing or formation 
of ice on the moving sensor element the function is restricted 
for the period of icing.
The output signal of the sensor conforms to the Modbus RTU 
to RS-485 standard.

2.8.3  Safety regulations

Because the wind sensor is often mounted in ex-
posed locations at dangerous heights the installation 
personnel have to pay attention to the relevant safety 
regulations. During the electrical installation work the 
external circuitbreaker must be switched off .
It is not permitted for unauthorized persons to open 
the housing!

Maintenance

3.1 

Regular maintenance and calibration

The sensors are very low-maintenance and designed for a 
very long lifetime. Regular visual checks are recomended, 
regarding dirt build-up on the surface caused by the weather. 
Whenever this is the case, we strongly recommend  that you 
clean it. A regular visual and functional check of the wind sen-
sor is recommended.

If reference measurements are necessary, it must be 
stringently noted that a comparison of the measured 
values is given only if the measurements take place 
under same conditions. I.e. the reference equipment 
must be used very close to the sensor!

The sensor is a measuring instrument and thus user specifi c 
standards apply regarding the period of recalibration. 
Manufacturer's recommendation: 2 years.
For the long-term assurance of the function and accuracy of 
the proposed components, we are pleased to off er you our 
professional maintenance and calibration services.

3.2 

Visual check and cleaning

The use of the sensor under the respective environmental 
conditions requires certain actions. It is thus recommendable 
to clean the outside of the housing and shelter within specifi c 
intervals. The intervals are dependant on the environmental 
conditions and the degree of soiling. We recommend a regular 
visual and functional check.

In case you should be faced with any specifi c problems, which 

you are unable to solve, please contact the LAMBRECHT 

meteo service:
Tel.:  

+49-(0)551-4958-0

Fax:  

+49-(0)551-4958-327

E-Mail:   [email protected]

Transport

In case it is necessary for you to ship or transport the sensor, it 
must be carefully packed to prevent damages during transport.

4

Содержание ARCO-Modbus

Страница 1: ...ishes for high durability Low starting value of 0 3 m s Very large measuring range from 0 3 to 75 m s Quick and easy installation by pipe mounting and M12 plug connector Integrated regulated heater for optimal heating of the sensor heads Thermal separation between sensor heads and the hous ing Changeable wind vane and three armed cup anemom eter Sensor head with integrated obstacles prevents infilt...

Страница 2: ...cularly qualified for use under severe environmental conditions The housing and the measuring elements are made of seawater resistant aluminium alloys The housing the cup rotor and the wind vane are anodised An electronically controlled sensor heating device allows for operation of the sensor over the wide range of 30 70 C 2 Start up Wind can be represented by a vector quantity For a complete descr...

Страница 3: ...ing is marked accordingly see drawing Adjust the sensor to the north before tightening the screws Please make sure that the sensor is firmly attached to the mast 2 8 1 Alignment of wind vane For wind direction measurements the north mark on the sen sor must be aligned with the geographical north direction To adjust the wind sensor in a firm and correct manner into the north direction this item is eq...

Страница 4: ...s often mounted in ex posed locations at dangerous heights the installation personnel have to pay attention to the relevant safety regulations During the electrical installation work the external circuitbreaker must be switched off It is not permitted for unauthorized persons to open the housing 3 Maintenance 3 1 Regular maintenance and calibration The sensors are very low maintenance and designed ...

Страница 5: ...Manual Combined Wind Sensor ARCO Modbus 14581 ARCO Modbus Manual 5 Dimensional drawing ARCO Modbus 5 ...

Страница 6: ...Manual Combined Wind Sensor ARCO Modbus 14581 ARCO Modbus Manual Electrical connection ARCO Modbus 6 ...

Страница 7: ...transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 6 2 Device address The addresses 1 247 are permitted for Modbus 6 3 Standard configuration Default Baud rate 19200 Baud Address Each sensor type or family has its own default address Default addresses of the LAMBRECHT sensors Address Sensor 1 ...

Страница 8: ...ensors but are only available or valid if the respective sensor supports the corresponding values e g a pure temperature sensor does not provide any wind speed The LAMBRECHT sensors give 0xD8F1 9999 16bit as error code or invalid value 6 6 Sensor parameters Configuration parameters Register address 40001 to 46000 contains the configuration parameter of the sensor Register address Parameter name Unit...

Страница 9: ... minimum and maximum values or additional values beyond this speci fication Unknown register addresses or registers that are not required must therefore be ignored during autoconfiguration Register address Parameter name Unit Factor Description Data type Func tion code Storage type 16 bit 30001 Wind speed instanta neous value m s 10 1 decimal place INT 0x04 Big Endian WORD 30201 Wind direction insta...

Страница 10: ...ss Register value Unit Factor Description 46001 30001 Register address 1 Wind speed instantaneous value INT 46002 30002 Register address 1 Wind speed average value since last retrieval INT 46003 30003 Register address 1 Wind speed maximum value INT 46004 30004 Register address 1 Wind speed minimum value INT 46005 30201 Register address 1 Wind direction instantaneous value INT 46006 30202 Register ...

Страница 11: ...o 32 14567 060010 various lengths possible Options 9340 Visualisation and evaluation software MeteoWare CS 3 Basic Id No 36 09340 000000 Standards EMC EMI EN 60945 Low voltage guideline 73 23 EWG and VDE 0100 WMO No 8 VDI 3786 part 2 NMEA 0183 8 Warranty Please note the loss that unauthorised manipulation of the system shall result in the loss of warranty and non liability Changes to system compon...

Отзывы: