Technical data

12.1  Electrical and mechanical data

Display: 

LCD type: transmissive; high-con-

trast; black & white; with back-

ground illumination

Resolution: 

160 x 128 dots

Dot size: 

0.54 x 0.54 mm

Dot distance: 

0.58 x 0.58 mm

Visible display space:  101 x 82 mm
Galvanic separation: 

DC power supply to the  

serial port RS 485

Power supply: 

9 ...36 VDC (24 VDC)

Power consumption: 

2.5...5 W

Outer dimensions: 

144 x 144 x 72 mm = standard 

160 x 160 x 78 mm = W-versions*

Panel cutout: 

138 x 138 mm

Required depths: 

approx. 125 mm with connectors  

and cables

Weight: 

approx. 0.8 kg

Type of protection: 

IP 23 according to DIN 40 050 

(front plate design of W-versions*  

in the style of IP 66)

Range of application:  Operation temp.: 0...+50 °C  

Storage temp: -20...+60 °C

Relative humidity: 

95 % r. h.; no condensation

Standards

 

Low voltage guideline 72/23/EWG

 

Standard of construction VDE 0100 

 EMC 

guidelines:

 

DIN EN 50081/ 82; DIN EN 60945

 

For NAV versions added: 

 

EMC guidelines VG 95373;  

IEC 61000-4-3 /4-6   

Shock resistance BV 0430,  

diagram 3 

Shock Class A 

ESD / Burst IEC 61000-4-2/ 4-4 

 

Vibration BV 0440, diagram 1, 8, 9

* W-versions = water resistant

12.2  Interface design specification (IDS)

For the display of the meteorological parameters the NMEA 

0183 message strings as mentioned below are required by 

the indicator. From the received message string containing the 

a.m. parameters the indicator electronic filters, converts and 

displays the required information. Regarding the sequence 

of the messages in a common string there is no explicit re-

quirement. As the indicator is evaluating the three-letter-code 

with sentence formatters only the performance of the talker 

identifier is not considered.

Air pressure/ barometer: $ - - MMB
Air temperature: 

$ - - MTA

Humidity (rel. & abs.):  $ - - MHU - remark: this information  

 

also includes the dew point temp.

Wind (relative): 

$ - - MWV

Wind (true) 

$ - - MWD

Data interface: 

RS 422 / RS 485 

Message format: 

NMEA 0183

Baud rate: 

4800 = standard (furthermore  

 

available 9600, 19200, 38400)

Frame format: 

8 N 1

Sequence of messages: arbitrary

Содержание aem METEO-LCD 14742

Страница 1: ...METEO LCD 14742 USER MANUAL Multifunctional Display Unit...

Страница 2: ...V3 mode change between TRUE REL MET 7 7 3 3 Baud rate 7 7 3 4 Language 7 7 4 Setup menu SYSTEM SETUP 2 7 7 4 1 Selection of wind protocol 7 7 4 2 Wind speed unit 7 7 4 3 Mean values 8 7 4 4 Pre sample...

Страница 3: ...and brightness can be set by the user For the signal input a serial RS 422 interface is provided All incoming data are expected as digital message strings according to the NMEA 0183 standard which no...

Страница 4: ...screws have to tightened securely evenly and enough fast so that there is no space between the frame of the indicator and the panel Because of the only small amount of heat through the maximum power c...

Страница 5: ...on the back side designated with RS 232c 9 pole sub D connector is for configuration and service purposes in the factory only The functions and signals of the connectors are described in the tables b...

Страница 6: ...on the indicator model 7 3 2 1 Wind speed and direction WIND The asterisk behind the WIND mode indicates further avail able parameters to be selected in the next lower level of the menu When selecting...

Страница 7: ...ng is done as before by for wind graph or for numerical display for all affected measured values for numerical display for all affected measured values Changed settings SYSTEM SETUP 2 wind only if NAV...

Страница 8: ...due to turbulent conditions To obtain a certain damping behavior of the display a pre sampling filter can be activated This figure in expressed in seconds defines the amount of measuring values to be...

Страница 9: ...brightness respectively contrast The set mode finally can be left pressing the SET button again in order to return to the normal operational conditions When pressing the arrow buttons in the regular m...

Страница 10: ...DIN EN 50081 82 DIN EN 60945 For NAV versions added EMC guidelines VG 95373 IEC 61000 4 3 4 6 Shock resistance BV 0430 diagram 3 Shock Class A ESD Burst IEC 61000 4 2 4 4 Vibration BV 0440 diagram 1 8...

Страница 11: ...by unauthorized manipulation of the system You need a written permission of LAMBRECHT meteo GmbH for changes of system components These activities must be operated by a qualified technician The warra...

Страница 12: ...own Roll degrees port down Example PPPRP 00 10 02 00 57 CR LF WIMWD Wind direction and speed WIMWD x x T x x M x x N x x M hh CR LF checksum wind speed m s wind speed unit kn wind direction 0 359 degr...

Отзывы: