aem.eco
LAMBRECHT meteo
|
AEM
|
8121
page
–
6
General technical data
ID
00.08121.100002
Measuring element
Piezoresistive pressure measuring cell
Pressure medium
Clean, dry air or other non-condensing and non-corrosive gases
Measuring range
600...1100 hPa resp. 800...1100 hPa
Pressure limits
Min. 300 hPa; max. 1,375 hPa
Accuracy
± 1 hPa within the temperature range -10...+60 °C ;
< ± 2 hPa within the temperature range -20...-10 °C
Resolution
0.1 hPa
Range of application
Altitudes:
0…4000 m
Temperatures: -20…+70 °C
Humidity:
0...99 % r. h. non-condensing
Housing
Polycarbonate; RAL 7035 (light gray); IP 66; for wall mounting; 1 cable gland ;
1 pressure equalization; 2 m connection cable 4-pin
Electrical
connection
6-pole female clamp connector for solid wire or cord with end sleeves, suitable for wire
cross sections of 0.5...1.5 mm
2
resp. AWG 20...16
Dimensions
130 x 80 x 60 mm
Weight
Approx. 0.3 kg with cable
Electrical data
Supply voltage
20 mA mode: 12... 30 VDC, smoothed, not stabilized
2 V mode: 5...30 VDC, smoothed, not stabilized
To drive a current of 20 mA through a signal line with a series resistance of 600
Ω
a power supply voltage of 18 V minimum is needed.
Current consumption
12...30 V; 20 mA mode; without load: < 10 mA quiescent current; typically approx. 8 mA
12...30 V; 20 mA mode; 20 mA output: < 30 mA; typically approx. 28 mA
12...30 V; 2 V mode, without load: < 3 mA; typically approx. 2 mA
5...30 V; 2 V mode; 1000
Ω
load resistance: < 5 mA; typically approx. 4 mA
(5...30 V; 2 V mode; 470
Ω
load resistance: < 7 mA; typically approx. 6 mA;
not specified)
Power consumption
30 V x 30 mA = 900 mW max.; 5 V x 2 mA = 10 mW min.
Analog outputs
0...20 mA; 4...20 mA; 0...2 V selectable/ adjustable
Current output: 20 mA max.; 30 V max.; series impedance 600
Ω
max.
Voltage output: 2 V max. at 1000
Ω
min., parallel 100 nF max.
Inrush current depending on source impedance, equivalent capacity at power supply
input: approx. 47 µF.
Time from power on to first valid value: approx. 3 seconds.
Every following measurements are taken in intervals of approx. 3 seconds. Due to
sealing of the enclosure measured values lag behind the true pressure by 30 s...60 s.
Содержание aem 8121