Lambrecht aem 8121 Скачать руководство пользователя страница 6

aem.eco

LAMBRECHT meteo    

|

    AEM

    |

 

   8121

page 

 

6

General technical data

ID

00.08121.100002

Measuring element

Piezoresistive pressure measuring cell

Pressure medium

Clean, dry air or other non-condensing and non-corrosive gases

Measuring range

600...1100 hPa resp. 800...1100 hPa

Pressure limits

Min. 300 hPa; max. 1,375 hPa

Accuracy

± 1 hPa within the temperature range -10...+60 °C ;  
< ± 2 hPa within the temperature range -20...-10 °C

Resolution

0.1 hPa

Range of application

Altitudes: 

0…4000 m 

Temperatures:   -20…+70 °C  
Humidity:  

0...99 % r. h. non-condensing

Housing

Polycarbonate; RAL 7035 (light gray); IP 66; for wall mounting; 1 cable gland ;  
1 pressure equalization; 2 m connection cable 4-pin

Electrical 

connection 

6-pole female clamp connector for solid wire or cord with end sleeves, suitable for wire 
cross sections of 0.5...1.5 mm

2

 resp. AWG 20...16

Dimensions 

130 x 80 x 60 mm

Weight

Approx. 0.3 kg with cable 

Electrical data

Supply voltage

20 mA mode: 12... 30 VDC, smoothed, not stabilized
2 V mode: 5...30 VDC, smoothed, not stabilized
To drive a current of 20 mA through a signal line with a series resistance of 600 

Ω 

a power supply voltage of 18 V minimum is needed.

Current consumption

12...30 V; 20 mA mode; without load: < 10 mA quiescent current; typically approx. 8 mA
12...30 V; 20 mA mode; 20 mA output: < 30 mA; typically approx. 28 mA
12...30 V; 2 V mode, without load: < 3 mA; typically approx. 2 mA
5...30 V; 2 V mode; 1000 

Ω 

load resistance: < 5 mA; typically approx. 4 mA

(5...30 V; 2 V mode; 470 

Ω 

load resistance: < 7 mA; typically approx. 6 mA;  

not specified)

Power consumption

30 V x 30 mA = 900 mW max.; 5 V x 2 mA = 10 mW min.

Analog outputs

0...20 mA; 4...20 mA; 0...2 V selectable/ adjustable
Current output: 20 mA max.; 30 V max.; series impedance 600 

Ω 

max.

Voltage output: 2 V max. at 1000 

Ω 

min., parallel 100 nF max.

Inrush current depending on source impedance, equivalent capacity at power supply 
input: approx. 47 µF.

Time from power on to first valid value: approx. 3 seconds.

Every following measurements are taken in intervals of approx. 3 seconds. Due to 
sealing of the enclosure measured values lag behind the true pressure by 30 s...60 s.