Lambrecht 9164 Скачать руководство пользователя страница 8

OPERATING INSTRUCTIONS 
METEODIGIT IV (9164) 

 

 

 

 8  

10. MEASURING OPERATIONS 

With METEODIGIT IV all available measuring channels 
are scanned by default semi-continuously; this permits 
continuous differential measurements. Depending on 
sensor up to 4 measuring channels can be displayed.  
 

10.1 Measuring value 

After switching ON first of all a 
segment test is performed; the 
battery voltage appears and if 
the batteries are almost empty 
(<3.6V) the LOBAT arrow 

 also appears.  

 
The measured value is then 
displayed with the appropriate 
units in the main field and the 
measuring point is displayed in 
the function field. All special 
operating states possible for 
the measured value are 
explained in section 8.4.  
 
 

10.1.1 Selecting a measuring point

 

By pressing key 

      M

   

 you can select one after the 

other all active measuring points and have the current 
measured value displayed for each. By pressing key

     

M

  

 you can return to previous channel.  

To increment the measuring channel press key: 

   M

   

To decrement the measuring channel press: 

   M

   

When switching between channels the abbreviation for 
the measuring range is briefly displayed. 

 

10.1.2 Measuring ranges

 

With each channel switchover or sensor breakage the 
abbreviation for the measuring range appears in the 
display. For identification purposes the following table 
lists all possible measuring ranges. 

Sensors Dim 

Abbr

Millivolt  

mV 

U 55 

Millivolt  1  

mV 

U 26 

Millivolt  2  

mV 

U260 

Volt  

U2

.

60 

Difference millivolt   

mV 

d 55 

Difference millivolt  1  

mV 

d 26 

Difference millivolt  2  

mV 

d260 

Difference volt  

d2

.

60 

Sensor voltage 

UbAt 

Frequency 

Hz 

FrEq 

Function channels: 

 

Maximum value of channel Mb1 

 

 Hi 

Minimum value of channel Mb1 

 

 Lo 

Measured value of Mb1 

 

 MESS 

Cold junction temperature 

°C 

  CJ 

10.1.3 Double display 

On all double sensors in-
corporating a temperature sen-
sor on the 1st channel the 
temperature value can be 
displayed in the function field 
at the same time. 

 

Select 2nd channel:  

Activate temperature display: 

  M

 

 

Press and hold down.

 

Return to channel display:  

  M

 

 

Press and hold down.

 

10.2 Peak value memory  

From the measured values 
acquired for each measuring 
point the highest and the lowest 
values are continuously re-
corded. To display these high/ 
low peak values first the de-
sired channel must be set and 
then the 

      MAX     

 or 

      MIN     

 key 

must be pressed. As a check the display also includes 
the associated symbol.  
 
To display the maximum value press:  

   MAX       

To display the minimum value press:   

   MIN         

To delete the maximum value press and hold down:  

   MAX   

 

To delete the minimum value press and hold down:

   MIN    

 

To return to the measuring point display press key: 

   M

      

 

As soon as you clear the memory, the current measured 
value will appear (because measuring is continuous). 

10.3 Measured value memory  

METEODIGIT IV can save 99 measured values in 
memory locations P01 to P99. The measured data can 
be shown on the display.  

 

To save each such measured value press key  

   MEM       

 

The function field will show 
the memory location for about 
1 second e.g.: P02 
 
 
 
 

The value most recently 
saved then appears in the 
function field preceded by the 
symbol ´M´. 

 

 

 

To return to the channel display press: 

   M

      

 

 

Содержание 9164

Страница 1: ...and cost effective solution e g for production facilities quality management air conditioning technology and ventilating applications on ships and in scientific laboratories Digital measuring techniq...

Страница 2: ...tes Battery voltage 3 6V Unlocked for adjust purposes Measured value corrected Relative measuring Operating keys ON OFF Switch ON to switch OFF press long M M Meas point selection MAX MIN Max min valu...

Страница 3: ...onitoring 6 7 2 Switching ON OFF reinitialization 6 8 CONNECTING THE SENSORS 6 8 1 1 Sensors 7 8 1 2 Measuring inputs and additional channels 7 9 DISPLAY AND KEYPAD 7 9 1 1 Display 7 9 1 2 Keypad 7 10...

Страница 4: ...z The device is damaged by electrostatic dis charge or lightning z Improper handling respectively non observance of the operating instructions The manufacturer reserves the right to change the product...

Страница 5: ...ot use the device inside detonation areas or filling stations 4 1 1 Special notes on use If the device is brought into the work room from a cold environment there is a risk that conden sation might fo...

Страница 6: ...ement It is possible by setting the measured value to zero to perform relative measuring operations with respect to a reference value 6 INITIAL COMMISSIONING 1 Connect sensor to socket M0 1 2 Ensure t...

Страница 7: ...igits b for depicting various measuring func tions a there are also 4 arrows f for depicting the operating status Function field Main field Display of measuring functions in the function field Measuri...

Страница 8: ...d 55 Difference millivolt 1 mV d 26 Difference millivolt 2 mV d260 Difference volt V d2 60 Sensor voltage V UbAt Frequency Hz FrEq Function channels Maximum value of channel Mb1 Hi Minimum value of ch...

Страница 9: ...CLR Select the next digit or entry is completed ON To terminate or cancel configuration MEM 11 1 Moving average METEODIGIT IV offers all the possibilities to calculate the average value In the first...

Страница 10: ...e listed checks and reme dial steps the device still fails to behave as described in the operating instructions it must be returned to our factory in Goettingen with error description 13 DECLARATION O...

Страница 11: ...ly not separated Housing L 127 x B 83 x H 42 mm ABS weight approx 260 g Suitable conditions Operating temperature 10 50 C storage temperature 20 60 C Ambient relative humidity 10 90 r h non condensati...