- 37 -
ENGLISH
GENERAL
LAYOUT OF THE MAIN COMPONENTS
MEGA 92÷1060
1 Control
panel
2
Burner attachment flange
3
Smokebox cleaning door
4
Flame inspection window
T1 Central heating flow outlet
T2 Central heating return inlet
T3 Expansion vessel attachment
T4 Boiler
drain
T5 Flue
attachment
T6 Burner attachment fitting
TECHNICAL SPECIFICATIONS
DESCRIPTION
92
107
152
190
240
300
350
399
Heat output
min
60
70
100
137
160
196
228
260
kW
max
92 107 152 190 240 300 350
399
kW
Heat input
min
64,3
75
107,3
147,4
170,9
209,5
242,5
277,5
kW
max 99,5
116,3
165
206,5
261
326
378
432
kW
Total boiler capacity
117
117
154
227
283
274
326
326
l
Water side pressure drop
10°C
8
11
20
12
17
40
48
43
mbar
15°C
4
6
12
7
10
17
23
32
mbar
20°C*
2
2
5
3
4
9
13
16
mbar
Flue gas side pressure drop
0,5
0,7
1,2
1,2
2,3
3,3
4,4
4,4
mbar
Maximum operating pressure
6
6
6
6
6
6
6
6
bar
DESCRIPTION
469
525
600
720
820
940
1060
Heat output
min
305
341
390
468
533
611
689
kW
max
469
525
600
720
820
940
1060
kW
Heat input
min
325
364,5
417
502
566
651
731
kW
max 507
567,5
648
781
881
1014
1140
kW
Total boiler capacity
421
421
498
707
802
727
819
l
Water side pressure drop
10°C
34
40
51
32
40
51
65
mbar
15°C
18
22
28
18
25
25
33
mbar
20°C*
10
12
16
10
18
16
20
mbar
Flue gas side pressure drop
3,3
4,3
4,8
4,5
5,6
5,4
6
mbar
Maximum operating pressure
6
6
6
6
6
6
6
bar
(*) Temperature difference.
- If used in combination with heavy oil burners, the values indicated must be reduced by around 10% .
Содержание MEGA 1060
Страница 2: ......
Страница 13: ...13 ITALIANO INSTALLAZIONE COLLEGAMENTO PANNELLO ELETTRICO MEGA 92 300 MEGA 350 1060...
Страница 30: ......
Страница 41: ...41 ENGLISH INSTALLATION ELECTRICAL PANEL CONNECTION MEGA 92 300 MEGA 350 1060...
Страница 58: ......
Страница 69: ...69 INSTALLATION FRAN AIS RACCORDEMENT PANNEAU ELECTRIQUE MEGA 92 300 MEGA 350 1060...
Страница 86: ......
Страница 97: ...97 INSTALACI N ESPA OL CONEXI N PANEL EL CTRICO MEGA 92 300 MEGA 350 1060...
Страница 114: ......
Страница 115: ......